Specifications Information and Repair Parts Manual
2874-95 thru 2879-95
2874-251-00
1
10/2016
Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate
or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating
Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions
for future reference. AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.
©2016 AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.
Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so
voids warranty.
3-Inch Self-Priming Centrifugal Pumps
Refer to pump manual 1808-634-00 for General Operating and Safety Instructions.
All units are for use with non-flammable, non-abrasive liquids compatible
with pump component materials.
MAINTENANCE
Make certain that the unit is disconnected and locked out from the power
source before attempting to service or remove any components.
NOTE:
Pump casing should be removed and inspected periodically to ensure
that any foreign material or rust is not clogging internal pump parts. This unit is
equipped with a dual volute pump casing. One of the volutes runs 180 degrees,
all the way from side opposite discharge into discharge through a completely
enclosed passageway. If foreign material clogs this area, it can be dislodged
by using a wire or long spring.
REMOVAL OF OLD SEAL
Refer to Figure 1
IMPORTANT:
Always replace both seal seat (Ref. No. 10) and seal head (Ref.
No. 11) to ensure proper mating of components! Also, impeller seal washer
(Ref. No. 14) should be replaced anytime impeller lock bolt (Ref. No. 15) has
been removed.
1. Remove four bolts (Ref. No. 4) that connect adapter (Ref. No. 7) to casing
(Ref. No. 16).
2. Remove casing and casing seal (Ref. No. 8).
Care should be taken not to “pinch” or “shave” the o-ring gasket (Ref. No. 8)
between adapter and casing.
3. Using an Allen wrench, remove impeller lock bolt, impeller seal washer,and
impeller (Ref. No. 13).
IMPORTANT:
Care should be taken to ensure that same number of shim
washers (Ref. No. 12) are replaced behind impeller as were removed. These
shim washers are located directly behind impeller. These washers as well as
impeller key (Ref. No. 2) become loose as impeller is removed.
4. Seal head and shaft sleeve can now be pulled from shaft.
5. Pry seal seat from adapter.
6. Push seal head from shaft sleeve.
INSTALLATION OF NEW SEAL
The precision lapped faces on mechanical seal are easily damaged. Handle
your replacement seal carefully.
1. Thoroughly clean all surfaces of seal seat cavity.
2. Using a clean cloth, wipe shaft and shaft sleeve and make certain that
they are perfectly clean.
3. Wet the rubber portion of new seal seat with a light coating of soapy water.
While wearing clean gloves or using a clean light rag, press seal seat
squarely into adapter recess. Avoid scratching polished surface. If seal will
not position properly, place a cardboard washer over polished surface and
use a piece of pipe to press in, firmly but gently.
4. Dispose of cardboard washer. Check again to see that polished surface is
free of dirt and all other foreign particles and that it has not been scratched
or damaged.
5. Wet the inside of rubber portion of new seal head with a light coating of
soapy water. Slide head onto shaft sleeve. Slide shaft sleeve with seal
head onto motor shaft. Seal head and seal seat will meet. Reinstall any
shims which have been removed. (See SHIM ADJUSTMENT section.)
IMPORTANT:
Before installing new shaft sleeve, apply a bead of non-
hardening, pliable sealant (such as Permatex®, Form-A-Gasket® No. 2) to
motor shaft shoulder.
6. Replace impeller key and impeller. Replace impeller seal washer before
screwing impeller lock bolt in place.
7. Reassemble pump.
8. A short “run-in” period may be necessary to provide completely leak free
seal operation.
DESCRIPTION
These centrifugal pumps are self-priming (to 20 ft. lift) units designed for high volume liquid transfer – irrigation, de-watering, lawn sprinkling, etc. They can also
accommodate semi-solids (up to 3/8” diameter), sediment laden liquids and liquids with entrained air or gases. Casing working pressure to 125 psi (862 kPa).
The units are equipped with a cast iron pump casing designed with a full dual volute, clog resistant semi-open stainless steel impeller and a cast iron adapter.
Units are equipped with flapper valves to ensure a positive prime. A mechanical seal isolates the motor from the liquid in the pump casing. The units are coupled
to 3450 RPM, totally enclosed fan cooled motors. All units are manual models, no controls are supplied. For use with nonflammable, non-abrasive liquids compat
-
ible with pump component materials.
Summary of Contents for 2877-95
Page 4: ......