![Amron 2820A User Manual Download Page 28](http://html1.mh-extra.com/html/amron/2820a/2820a_user-manual_2935931028.webp)
2820A-XX & 2825A-XX SERIES TWO DIVER COMMUNICATOR USER MANUAL
282XA-UM
REV 5.0
24
4. Identify the microphone and headset leads. When using an Amron headset, the
microphone is the red banana plug and the headset is the black banana plug.
5. Plug the microphone lead into the TENDER HEADSET (black) jack and the headset
lead into the DIVER MICROPHONE (red) jack.
6. Don the headset. Talk into the microphone while pressing the PUSH-TO-TALK
BUTTON. You should be able to hear yourself in the headset. Adjust the TENDER
TO DIVER VOLUME control and verify that the level can be adjusted to a
comfortable level.
7. Unplug the microphone lead. Turn on the SPEAKER SWITCH. Press the PUSH-TO-
TALK BUTTON while speaking into the PANEL SPEAKER. You should be able to
hear yourself in the headset. Adjust the TENDER TO DIVER VOLUME if necessary
and verify that the level can be adjusted to a comfortable level.
8. Plug the microphone lead into the TENDER HEADSET (black) jack. Short the PUSH-
TO-TALK JACK (yellow) with a short piece of wire. Talk into the microphone and
verify that you hear yourself in the headset. Remove the short. Turn off the
SPEAKER SWITCH.
9. Move the microphone lead to the DIVER MICROPHONE (red) jack and move the
headset lead to the TENDER HEADSET jack.
10. Talk into the microphone and verify you can hear yourself in the headset. The PUSH-
TO-TALK BUTTON should not be pressed. Adjust the DIVER TO TENDER.
5.3
GENERAL MAINTENANCE
The AMCOM II diver communicator is designed to provide years of continuous, failure-free
service when properly used and maintained. There are a few important things that the user
can do to extend the life of their equipment.
1. Handle the diver communicator with care. Do not throw it around or drop it. Select a
work area where the communicator and wire connecting to it are out of everyone's
way so it is not knocked over.
2. Clean the communicator after use or when needed. If the equipment is on an
extended work program, have the tender clean the equipment during slow work
periods. Rinse off salt deposits with fresh water. Clean the diver connections with a
mild vinegar and water solution using a soft brush. Rinse off the connectors with
water after cleaning.
5.4
RECOMMENDED MAINTENANCE SCHEDULE
The following sections outline the recommended scheduled maintenance for the
communicator and communicator.