background image

 

 

 
 
 
 
 
 
 

 
 
 
 
 
 

User Manual 

for 

Amron International, Inc. 

 

Amron Model 2810E-2001 

Single Lock Chamber Communicator 

S/N______________________ 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1380 Aspen Way, Vista California 92081-8349 

United States of America 

Phone: (760) 208-6500 

Fax (760) 599-3857 

email[email protected] 

web: www.amronintl.com 

 

This manual and the information contained herein are provided for use as an operation and 
maintenance guide. No license or rights to manufacture, reproduce, or sell either the manual or 
articles described herein are given. Amron International, Inc. reserves the right to change 
specifications without notice. 

Copyright© 2013 Amron International, Inc. 

Summary of Contents for 2810E-2001

Page 1: ...0 Fax 760 599 3857 email sales amronintl com web www amronintl com This manual and the information contained herein are provided for use as an operation and maintenance guide No license or rights to m...

Page 2: ......

Page 3: ...E POLICY 6 2 2 3 CONTROLS AND CONNECTIONS 7 OPERATOR AND CHAMBER CONTROLS 7 3 1 CHAMBER CONNECTIONS 10 3 2 4 OPERATION 12 CHARGING THE BATTERY 12 4 1 INITIAL POWER ON BATTERY CONDITION CHECK 12 4 2 MO...

Page 4: ......

Page 5: ...communicator on the market To enjoy all the features it is important that the operator read and understand the entire manual including all warnings The 2810E 2001 can operate in 2 Wire or Full Duplex...

Page 6: ...MODEL 2810E 2001 FRONT PANEL 1 4 All of the controls for the Model 2810E 2001 are located on the front panel including the connectors for the operator handheld microphone or headset tape recorder and...

Page 7: ...01 28 The Model 2401 28 is a heavy duty headset with boom microphone It comes equipped with color coded dual banana plugs that mate directly to AMCOM chamber communicators It includes a six foot 1 8 m...

Page 8: ...d comfortable headset is designed for extended wear by chamber occupants The Model 2460 31R features an adjustable boom microphone vinyl cushioned adjustable ear pads and a spiral cord that can be ext...

Page 9: ...el 3115 It also includes a sound powered phone with bracket chamber temperature probe scrubber power circuit wiring chamber environmental conditioning unit wiring and electrical penetrator adaptor all...

Page 10: ...imited to the repair of or replacement of materials at Amron s discretion This warranty shall not cover defects which are the result of misuse negligence accident repair or alterations SERVICE POLICY...

Page 11: ...he power on off control 3 1 2 SPEAKER SWITCH This switch allows the operator to turn off the speaker If the operator is using a headset it may be necessary to turn off the speaker in order to prevent...

Page 12: ...ll Duplex 4 Wire mode regardless of the mode used for the chamber To connect the operator in the Full Duplex 4 Wire mode connect the earphone black banana plug of the headset to this jack and the micr...

Page 13: ...e as a microphone This allows another operation crew member to talk to the occupants using the PANEL SPEAKER even if the operator is away from the 2810E 2001 using the Remote Push to Talk Module in 2...

Page 14: ...T CHAMBER CONNECTIONS 3 2 The chamber connections are located on the rear left side of the communicator CHAMBER MICROPHONE This is a dual banana jack color coded red that functions as both an output e...

Page 15: ...ANUAL 2810E 2001 UM REV 3 0 11 3 2 3 CHAMBER EARPHONE This is a dual banana jack color coded black that functions as the output for chamber occupant s earphone It is only used when the chamber is in F...

Page 16: ...s or 3 years The BATTERY CONDITION INDICATOR will start to blink when the battery has approximately 30 remaining charge To maximize the service life the battery should be recharged as soon as possible...

Page 17: ...BUTTON the occupant hears the operator Often times a 4 conductor communication cable is used with 2 wires tied together as a pair for redundancy this is still a 2 Wire system Since only one person can...

Page 18: ...rn speaker switch to OFF adjust both volume controls to mid scale Operator and occupants use headsets and talk to each other while the operator adjusts the volume controls as below OPERATOR VOLUME Whi...

Page 19: ...then replace or recharge the battery If that does not resolve the problem then go to the troubleshooting section to determine the cause 4 Identify the microphone and headset leads When using an Amron...

Page 20: ...he black banana plug 5 Plug the microphone lead into the OPERATOR HEADSET black jack and the headset lead into the CHAMBER MICROPHONE red jack 6 Don the headset Talk into the microphone while pressing...

Page 21: ...urn off unit 3 Disconnect all cables 4 Remove 4 ea pan head Phillips screws 2 ea on each side of AMRON INTERNATIONAL 2 ea on each side of MODEL 2810E 2001 5 Lift the 2810E 2001 out of chamber control...

Page 22: ...rious front panel components attach to the panel 3 6 MONTH CHECK Wipe off any accumulated dust or dirt on the front panel or connectors using a clean damp cloth Pay particular attention to where the v...

Page 23: ...the POWER SWITCH and SPEAKER SWITCH are turned on is a bad or loose battery Check the battery per section 5 3 1 If the battery is good then disconnect any chamber wiring and perform the communicator c...

Page 24: ...ther defect Replace if necessary If the operator is using a headset remove the headset and listen to the occupant using the PANEL SPEAKER If this solves the problem then the operator headset may be we...

Page 25: ...talk is caused by signal leakage between the microphone and earphone wires in the communications cable In a good cable with all the wires open not connected the resistance between any two wires should...

Page 26: ...ical details of the chamber communication unit The corresponding parts lists for each drawing are detailed in the parts lists section or are included as part of the drawing All drawings are at their c...

Page 27: ...MODEL 2810E 2001 USER MANUAL 2810E 2001 UM REV 3 0 23 FRONT PANEL PARTS LOCATOR MODEL 2810E 2001 6 1...

Page 28: ...MODEL 2810E 2001 USER MANUAL 2810E 2001 UM REV 3 0 24 MOUNTING DETAIL MODEL 2810E 2001 6 2...

Page 29: ...Order Replacement Parts Contact Amron International Inc 1380 Aspen Way Vista California 92081 U S A Telephone 760 208 6500 Fax 760 599 3857 Email sales amronintl com Web www amronintl com When orderin...

Page 30: ...01 01 Jack RCA Red Panel Mount 52 160 1001 02 Jack RCA White Panel Mount N S 10 32x3 4SSPSP Screw 10 32X3 4in S S Phillips N S 10LWSSS Washer Split Locking 10 S S N S 8 32x5 8SSPHP Screw 8 32X5 8in S...

Page 31: ...Reference Part Number Description Quantity 1 105 0603 001 Jack Tip Black 1 2 105 0602 001 Jack Tip Red 1 3 1498 103 Jack Banana Black 2 4 1498 102 Jack Banana Red 2 5 1498 107 Jack Banana Yellow 2 6...

Reviews: