Amroad DP101R Installation Manual Download Page 1

 

 
 

AMROAD DP101R 

DOOR STATION 

 

Installation Manual

 
 
 

 

 

Summary of Contents for DP101R

Page 1: ...AMROAD DP101R DOOR STATION Installation Manual...

Page 2: ......

Page 3: ...2 Rear Side 3 Reset Button 3 Installing Procedures 4 Back Plate 4 Wire and Cable Connection 5 Screw Main Unit 6 IO Application 7 Electric Bolt 8 Electric Bolt and Open Button 9 Electric Strike 10 Ele...

Page 4: ...0 x4 5 L shaped screw driver for security screws x1 6 Water Stopper x4 7 Screw for Earth Wire x1 8 Wall mounted screw pack Self tapping screws TP3 L16 x4 Wall plugs x4 9 Terminal Connector x1 10 H typ...

Page 5: ...AMROAD DP101R The Size of Main Unit The Size of Main Unit 2...

Page 6: ...ed the reset button for 3 seconds IP is 192 168 0 50 2 When the button has been pressed for more than 6 seconds the device will be back to the factory setting and reboot itself 3 If press for more tha...

Page 7: ...the floor 2 Sets up Back Plate in accordance with the figure above 3 Use Wall Mounted Screw Pack to fix Back Plate on the wall 4 Connect the ground wire to the Back Plate Remember to tighten the screw...

Page 8: ...r 2 Connect the AC wire of DP101R to H type power connector Please be careful when you are connecting be sure to check the AC condition before you start to connect the wires 3 Please screw the earth c...

Page 9: ...front panel 2 Make sure Main Unit is attached on the wall for waterproof 3 Put back front cover 4 Apply Silicon Glue around the Main Unit if required to strengthen waterproof ability 5 Please double...

Page 10: ...ng Electric Strikes Electric Bolts and Electromagnetic locks Wiring Connection and Web Page Setup There are two types of electric door lock applications as below One is Electric Strike and the other i...

Page 11: ...AMROAD DP101R Electric Bolt The Electric Bolt is closed when 12 V is supplied The Electric Bolt is opened when 12V is not supplied IO Application Electric Bolt 8...

Page 12: ...AMROAD DP101R Electric Bolt and Open Button The Electric Bolt is closed when 12 V is supplied The Electric Bolt is opened when 12V is not supplied IO Application Electric Bolt 9...

Page 13: ...AMROAD DP101R Electric Strike The Electric Strike is opened when 12 V is supplied The Electric Strike is closed when 12V is not supplied IO Application Electric Strike 10...

Page 14: ...MROAD DP101R Electric Strike and Open Button The Electric Strike is opened when 12 V is supplied The Electric Strike is closed when 12V is not supplied IO Application IO Application Electric Strike 11...

Page 15: ...specifications which are the one we use on above applications Model name SS2415DZ General Characteristics Normal Open NO LED Input Specifications Control Current Arms Control Voltage Range Vrms DC 4...

Page 16: ...AMROAD TECHNOLOGY INC 17F 1 No 16 Jian 8th Rd Zhonghe Dist New Taipei City 235 Taiwan R O C TEL 886 2 8226 5686 FAX 886 2 8226 5687 info amroad com tw WWW AMROAD COM TW...

Reviews: