ACTIV-Pro3
assembly guide
Page 1: ...ACTIV Pro3 assembly guide ...
Page 2: ...eet 11 Adjusting Stretcher Bars 12 Connecting Power 13 Connecting Worksurface 14 Program Height Memory Presets 15 120 16 Components 17 Leg Attachment 18 Attaching Stretcher Bar 19 Attaching Cantilevers Feet 21 Adjusting Stretcher Bars 22 Connecting Worksurface and Power 23 Program Height Memory Presets 24 ...
Page 3: ...fore moving on castors 1 Adjust desk to lowest height 2 Verify path is clear of obstructions 3 Remove objects not attached to desk 4 Restrict monitor arms from moving outside desk perimeter This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received i...
Page 4: ...the appropriateness of their chosen work surface MANDATORY REQUIREMENTS REGARDLESS OF WORK SURFACE MATERIAL OR CONSTRUCTION FASTENERS Adjustable height bases include fasteners intended for use with AMQ work surfaces These fasteners may potentially also be suitable for work surfaces meeting the following criteria Medium density or higher particleboard or fiberboard cores with High pressure laminate...
Page 5: ...ngs have a polarized plug one blade is wider than the other like the plug illustrated in Figure 1 This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way INSTRUCTIONS FOR DOUBLE INSULATED PRODUCTS No grounding means is p...
Page 6: ...ACTIV PRO3 90 ...
Page 7: ...d leg x 2 center leg x 1 M10 x 8 M6 special x 8 wood screw x 23 M6 x 12 handset screw x 2 cable clips x 12 8mm 5mm allen keys 4mm screw caps x 8 stretcher bar end x 2 stretcher bar x 4 frame BL x 1 frame BR x 1 frame FL x 1 frame FR x 1 controller cable x 2 power cable handset x 1 power box x 1 90 mending plate x 2 ...
Page 8: ...ons com PHASE 1 Leg Attachment Step 1 Identify center leg Step 2 Assemble center leg to center bracket with M6 screws 2 1 Front Right Back Right Front Left and Back Left are indicated on Center Bracket with the initials FR BR FL and BL 90 ...
Page 9: ...ng Stretcher Bar 1 BL BR FL FR Step 1 Match up frames to center bracket lining up the holes to the degree that you are setting 90 or 120 Screw in with M6 screws 1 Note limit of stretch length and assemble base within that limitation maximum mounting distance 90 ...
Page 10: ...2 Assemble stretcher bars into the frames Step 3 Complete connecting the stretcher bars and stretcher bar ends Assemble end legs to the stretcher bar ends using M6 special screws NOTE Trim caps will be attached in Phase 4 2 3 For 48 width worksurfaces do not install stretcher bars 90 ...
Page 11: ...et Step 1 Plug cantilevers into the stretcher bar ends lining up holes Add screws M6 special Tighten using 4 allen key or a long extension angle tipped allen key to expedite the process 2 2 1 Step 2 Attach feet to legs with M10 screws NOTE Trim caps will be attached in Phase 4 90 ...
Page 12: ...Bars Step 1 Adjust stretcher bar to desired length NOTE The worksurface should be center aligned with the cantilever depth and should have equal amount of overhang on each end Step 2 Place caps 90 Make sure the screw bracket stays in the center of the stretcher bars 1 1 2 1 1 ...
Page 13: ...low 90 Facing Direction Connect each plugs according to the drawing Orientate yourself to the table assembly by facing as user to identify left and right motor Position handset wire into dedicated slot before screwing down base to worksurface Right Motor Left Motor Power Position wire into dedicated slots to keep them neat tidy before screwing down base to worksurface 1 ...
Page 14: ...rksurface using wood screws Step 2 Attach the handset to desired location using handset screws count x2 Step 3 Tighten 4 factory inset screws to hold desired length in place Step 4 Attach Mending Plates Applicable to ACTIV Pro3 90 using 2 piece worksurface setup to the worksurface using wood screws NOTE 1 piece worksurface setup does not need mending plates 90 4 3 2 1 ...
Page 15: ... 1 2 3 or 4 Step 2 To Test Programmed Height Use the up down arrows to adjust the table to a height other than the preset height Then push and hold the number you programmed to see if it automatically adjusts to the height programmed in Step 1 You may need to hold for 2 3 seconds to activate the base NOTE If it does not adjust to the programmed height repeat Step 1 followed by Step 2 AMQ 1 2 3 M 4...
Page 16: ...ACTIV PRO3 120 ...
Page 17: ...et x 1 end leg x 2 center leg x 1 M10 x 8 M6 special x 8 wood screw x 23 M6 x 12 handset screw x 2 cable clips x 12 8mm 5mm allen keys 4mm screw caps x 8 stretcher bar end x 2 stretcher bar x 4 frame BL x 1 frame BR x 1 frame FL x 1 frame FR x 1 controller cable x 2 power cable handset x 1 power box x 1 120 ...
Page 18: ...ons com PHASE 1 Leg Attachment Step 1 Identify center leg Step 2 Assemble center leg to center bracket with M6 screws 2 1 Front Right Back Right Front Left and Back Left are indicated on Center Bracket with the initials FR BR FL and BL 120 ...
Page 19: ...ng Stretcher Bar 1 BL BR FL FR Step 1 Match up frames to center bracket lining up the holes to the degree that you are setting 90 or 120 Screw in with M6 screws 1 Note limit of stretch length and assemble base within that limitation maximum mounting distance 120 ...
Page 20: ...2 Assemble stretcher bars into the frames Step 3 Complete connecting the stretcher bars and stretcher bar ends Assemble end legs to the stretcher bar ends using M6 special screws NOTE Trim caps will be attached in Phase 4 2 3 For 48 width worksurfaces do not install stretcher bars 120 ...
Page 21: ...t Step 1 Plug cantilevers into the stretcher bar ends lining up holes Add screws M6 special Tighten using 4 allen key or a long extension angle tipped allen key to expedite the process 2 2 1 Step 2 Attach feet to legs with M10 screws NOTE Trim caps will be attached in Phase 4 120 ...
Page 22: ... PHASE 4 Adjusting Stretcher Bars Step 1 Adjust stretcher bar to desired length Step 2 Tighten 4 factory inset screws to hold desired length in place Step 3 Place caps Make sure the screw bracket stays in the center of the stretcher bars 3 2 1 120 ...
Page 23: ... center aligned with the cantiliver depth and should have equal amount of overhang on each end Step 2 Attach the handset to desired location using handset screws count x2 Step 3 Plug in electrical according to the diagram at right Attach cable management clips if using Facing Direction Handset Power Connect each plugs according to the drawing Orientate yourself to the table assembly by facing as u...
Page 24: ... 1 2 3 or 4 Step 2 To Test Programmed Height Use the up down arrows to adjust the table to a height other than the preset height Then push and hold the number you programmed to see if it automatically adjusts to the height programmed in Step 1 You may need to hold for 2 3 seconds to activate the base NOTE If it does not adjust to the programmed height repeat Step 1 followed by Step 2 AMQ 1 2 3 M 4...
Page 25: ...Please contact cc amqsolutions com if you are missing any parts have difficulty with assembly or have any product related questions ...