Model 20T4G18
To open the enclosure:
1. Remove the amplifier from the cabinet or rack as follows:
NOTE:
Due to the weight of the unit, the removal of the amplifier from the cabinet or rack is a two
person operation.
Disconnect power, RF, and any other interface connectors. On the rear of the unit, remove any screws
used to connect brackets to the amplifier. On the front of the unit, remove the four screws holding the
front panel onto the cabinet. Carefully slide the amplifier out of the front of the cabinet.
2. Remove the 12 screws that secure the lower cover and the 12 screws that secure the upper cover. Remove
the covers to gain access to the interior of the TWTA.
Vacuum dust and debris from inside the enclosure. Clean dust from the TWTA and its flying leads.
Remove any dirt from around the three high voltage connectors. While the cover is off, check for loose
wires, components or fasteners.
Reassemble in the reverse order.
4.4 TROUBLESHOOTING
Symptom Possible
cause
TWT or power supply overtemperature
Air inlet filter dirty
Collector heat sink dirty
Inadequate clearance behind TWTA
High air inlet temperature
Defective blower or power supply
No response when main power turned on
Panel open interlock switch open
Control module display does not come up; unit does not beep when
powered up
Shorted or defective control module power supply
Control module failure
Control module does not boot
EPROM(s) missing.
Control module "datalink failure" or “Communication Problem” error
appears
HPA interface failure.
Fiberoptic link failure
+15 VDC supply failure
Heater power supply does not come up
Defective low voltage power supply module
Defective heater power supply module
No high voltage
Open external interlock
Keylock switch on "INHIBIT" or "REMOTE"
Defective high voltage power supply.
Voltages normal, but no RF output, helix current low
No RF input
Defective remote control board
Defective SSA
Gain turned down
After review of the symptoms of the failure
,
the user may want to check for a loose connector or component
especially after rough handling of the unit
.
Look externally for physical damage and internally for unmated or
loose parts
.
26
Rev B
http://www.Datasheet4U.com
Summary of Contents for 200T4G18
Page 2: ...Model 20T4G18 2 http www Datasheet4U com...
Page 4: ...Model 20T4G18 4 http www Datasheet4U com...
Page 6: ...Model 20T4G18 2 http www Datasheet4U com...
Page 8: ...Model 20T4G18 4 http www Datasheet4U com...
Page 38: ...Model 20T4G18 28 Rev B http www Datasheet4U com...
Page 42: ...Model 20T4G18 32 Rev B http www Datasheet4U com...
Page 44: ...Model 20T4G18 34 Rev B http www Datasheet4U com...
Page 58: ...Model 20T4G18 48 Rev B http www Datasheet4U com...
Page 60: ...http www Datasheet4U com...