Temposonics
®
R-Series
V
POWERLINK
Operation Manual
I 8 I
3.4 Order code of Temposonics
®
RDV
a
Design
R
D V
Detached sensor electronics “Classic”
b
Design
C
Threaded fl ange M18×1.5-6g (A/F 46)
D
Threaded fl ange ¾"-16 UNF-3A (A/F 46)
M
Threaded fl ange M18×1.5-6g (A/F 24)
S
Pressure fi t fl ange Ø 26.9 mm f6
T
Threaded fl ange ¾"-16 UNF-3A (A/F 23)
c
Mechanical options
For side cable entry
A
PUR cable with M16 connector, 250 mm length
B
PUR cable with M16 connector, 400 mm length
C
PUR cable with M16 connector, 600 mm length
For bottom cable entry
2
Single wires with fl at connector, 65 mm length
4
Single wires with fl at connector, 170 mm length
5
Single wires with fl at connector, 230 mm length
6
Single wires with fl at connector, 350 mm length
d
Stroke length
X X X X M
Flange »S«: 0025…2540 mm
Flange »C«, »D«, »M«, »T«: 0025…5080 mm
Stroke length (mm)
Ordering steps
25… 500 mm
5 mm
500… 750 mm
10 mm
750…1000 mm
25 mm
1000…2500 mm
50 mm
2500…5080 mm
100 mm
X X X X U
Flange »S«: 001.0…100.0 in.
Flange »C«, »D«, »M«, »T«: 001.0…200.0 in.
Stroke length (in.)
Ordering steps
1… 20 in.
0.2 in.
20… 30 in.
0.4 in.
30… 40 in.
1.0 in.
40…100 in.
2.0 in.
100…200 in.
4.0 in.
Non standard stroke lengths are available;
must be encoded in 5 mm/0.1 in. increments
.
e
Number of magnets
X X
01…30 position(s) (1…30 magnet(s))
f
Connection type
D 5 8
2 × M12 female connectors (D-coded),
1 × M12 male connector (A-coded)
D 5 6
2 × M12 female connectors (D-coded),
1 × M8 male connector
g System
1
Standard
h Output
U 3 0 1
POWERLINK, position and velocity
(1…30 magnet(s))
U 3 1 1
POWERLINK, position and velocity,
internal linearization (1…30 magnet(s))
NOTICE
• Specify the number of magnets for your application and order the
magnets separately.
• The number of magnets is limited by the stroke length.
The minimum allowed distance between magnets (i.e. front face
of one to the front face of the next one) is 75 mm (3 in.).
• Use magnets of the same type for multi-position measurement.
• If the option for internal linearization (U311) in
h
“Output” is
chosen, select a suitable magnet.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
R
D V
M
D 5
1
U 3
1
a
b
c
d
e
f
g
h