10. Technical data
10.1 Technical data Temposonics
®
RP5
Output
Interface
Ethernet POWERLINK
Data protocol
POWERLINK V2
Measured value
Position, velocity/option: Simultaneous multi-position and multi-velocity measurements up to 30 magnets
Measurement parameters
Resolution: Position
0.5…100 µm (selectable)
Cycle time
Stroke length
≤ 50 mm
≤ 715 mm
≤ 2000 mm
≤ 4675 mm
≤ 6350 mm
Cycle time
250 µs
4
500 µs
1000 µs
2000 µs
2800 µs
Linearity deviation
5
Stroke length
≤
500 mm
>
500 mm
Linearity deviation
≤ ±50 µm
< 0.01 % F.S.
Optional internal linearity
: Linearity tolerance (applies for the first magnet for multi-position measurement)
Stroke length 25…300 mm 300…600 mm 600…1200 mm 1200…3000 mm 3000…5000 mm 5000…6350 mm
typical
± 15 µm
± 20 µm
± 25 µm
± 45 µm
± 85 µm
± 95 µm
maximum
± 25 µm
± 30 µm
± 50 µm
± 90 µm
± 150 µm
± 190 µm
Repeatability
< ±0.001 % F.S. (minimum ±2.5 μm) typical
Hysteresis
< 4 µm typical
Temperature coefficient
< 15 ppm/K typical
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
IP67 (connectors correctly fitted)
Shock test
150 g/11 ms, IEC standard 60068-2-27
Vibration test
30 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN
61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The RP5 sensors fulfill the requirements of the EMC directives
2014/30/EU, UKSI 2016 No. 1091 and TR CU 020/2011
Magnet movement velocity Magnet slider: Max. 10 m/s; U-magnet: Any; block magnet: Any
Design/Material
Sensor electronics housing
Aluminum (painted), zinc die cast
Sensor profile
Aluminum
RoHS compliance
The used materials are compliant with the requirements of EU directive 2011/65/EU and
EU regulation 2015/863 as well as UKSI 2022 No. 622
Stroke length
25…6350 mm (1…250 in.)
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawing on
Electrical connection
Connection type
2 × M12 female connectors (D-coded), 1 × M8 male connector
2 × M12 female connectors (D-coded), 1 × M12 male connector (A-coded)
Operating voltage
+12…30 VDC
±
20 % (9.6…36 VDC)
Power consumption
Less than 4 W typical
Dielectric strength
500 VDC (DC ground to machine ground)
Polarity protection
Up to −36 VDC
Overvoltage protection
Up to 36 VDC
4/
Minimum cycle time for multi-position measurements (number of magnets ≥ 2): 400 µs
5/
With position magnet # 252 182
Temposonics
®
R-Series
V
POWERLINK
Operation Manual