8.2
Technical data Temposonics
®
RH5
Output
Analog
Voltage: 0…10 /10…0/−10…+10/+10…−10 VDC (min. controller load > 5 k
Ω
)
Current: 4(0)…20/20…4(0) mA (min./max. load 0/500
Ω
)
Measured output variables
Position for one or two position magnets
Po speed (without direction) or velocity (with direction) for one position magnet
Position for one position temperature inside the sensor electronics housing
Measurement parameters
Position measurement
Null/Span adjustment
100 % of electrical stroke
Resolution
16 bit (internal resolution 0.1 µm)
Update time
Stroke length
≤ 200 mm
≤ 350 mm
≤ 1200 mm
≤ 2400 mm
≤ 4800 mm
≤ 7620 mm
Update time
0.25 ms
0.333 ms
0.5 ms
1.0 ms
2.0 ms
5.0 ms
Linearity deviation
5
<
±0.01 % F.S. (minimum ±50 µm)
Repeatability
<
±0.001 % F.S. (minimum ±1 µm)
Hysteresis
< 4 µm typical
Temperature coefficient
< 30 ppm/K typical
Velocity measurement
Range
0.01…10 m/s or 1…400 in./s
Deviation
≤ 0.05 %
Resolution
16 bit (minimum 0.01 mm/s)
Operating conditions
Operating temperature
−40…+85 °C (−40…+185 °F)
Humidity
90 % relative humidity, no condensation
Ingress protection
IP67 (connectors correctly fitted)/IP68 (3 m/3 d) for cable outlet
Shock test
150 g/11 ms, IEC standard 60068-2-27
Vibration test
30 g/10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)/
RH5-J: 15 g / 10…2000 Hz, IEC standard 60068-2-6 (excluding resonant frequencies)
EMC test
Electromagnetic emission according to EN 61000-6-3
Electromagnetic immunity according to EN 61000-6-2
The RH5 sensors fulfill the requirements of the EMC directives 2014/30/EU, UKSI 2016 No. 1091 and
TR CU 020/2011
Operating pressure
350 bar (5,070 psi)/700 bar (10,150 psi) peak (at 10 × 1 min) for sensor rod/RH5-J: 800 bar (11,600 psi)
Magnet movement velocity
Any
Design/Material
Sensor electronics housing
Aluminum (painted), zinc die cast
Sensor flange
Stainless steel 1.4305 (AISI 303)
Sensor rod
Stainless steel 1.4306 (AISI 304L)/RH5-J: Stainless steel 1.4301 (AISI 304)
RoHS compliance
The used materials are compliant with the requirements of EU Directive 2011/65/EU and
EU Regulation 2015/863 as well as UKSI 2022 No. 622
Stroke length
25…7620 mm (1…300 in.)/RH5-J: 25…5900 mm (1…232 in.)
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawings on
5/
With position magnet # 251 416-2
Technical data “Electrical connection” on