4.1.28 iMac_SSW_Control_ModDT
This UDT stores the iMAC SSW Module Control data. It has the following members.
SIM_T_INPUT_STATUS
INT
Trolex Input Status 1 to 8
SIM_T_RELAY_STATUS
INT
Trolex Relay Status 1 to 8
SIM_T_ANALOG_CH
INT[8]
Analogue Input Channels 1 to 8
SIM_T_SOFTWARE_VERSION INT
Software Version *10 (Value divided by 10 ie 27
= version 2.7)
SIM_T_RS485_ERRORS
INT
Error Count for RS485 Communication
SIM_T_SERIAL_NUM
INT
SIM-T Serial Number
SIM_T_Status
iMac_STATUS_DT[16] Module Status A0 to A15
SIM_T_Resist
INT[16]
Module Resistance Value A0 to A15
SIM_T_Error
iMac_ERROR_DT[16]
Module Error Counters A0 to A15
Member Name
Data Type
Description
SSW_Control_Bit0_Setup_Mode
BOOL
Module Flags - Setup mode (1=Busy); The
setup process is busy.
SSW_Control_Bit1_Setup_Success BOOL
Module Flags - Setup successful (1=Success);
No failures occurred during the setup process.
SSW_Control_Bit2_Setup_Failed
BOOL
Module Flags - Setup failed (1=Failed); The
setup process failed due to a timeout or pulse
rate failure.
SSW_Control_Bit3_S1_Pulse_Slow BOOL
Module Flags - Sensor 1 pulse rate too slow
(1=Failed); Rate < 50ppm.
SSW_Control_Bit4_S1_Pulse_Fast BOOL
Module Flags - Sensor 1 pulse rate too fast
(1=Failed); Rate > 5000ppm.
SSW_Control_Bit5_S2_Pulse_Slow BOOL
Module Flags - Sensor 2 pulse rate too slow
(1=Failed); Rate < 50ppm.
SSW_Control_Bit6_S2_Pulse_Fast BOOL
Module Flags - Sensor 2 pulse rate too fast
(1=Failed); Rate > 5000ppm.
SSW_Control_Bit7_Setup_Timeout BOOL
Module Flags - Setup timeout (1=Timeout);
Setup failed to complete within 4 minutes.