ADVANCED WARNING
SYSTEMS
EV3000 Battery Detector
Installation Guide
Item Numbers: 154-0258
MAN3039
N1236
Page 1
WORLD LEADER OF INNOVATIVE SOLUTIONS IN FIRE DETECTION AND ALARM SYSTEMS
Ampac Technologies Australia
Tel: +61 8 9201 6100
Europe
Tel: +44 (0) 1302 833 522
New Zealand
Tel: +64 9 443 8072
www.ampac.net
Description:
The EV3000 Battery Detector monitors the Supply
Batteries for disconnection or removal. The relay
contacts allow for a FAULT condition to be generated at
the EV3000 panel.
The EV3000 Battery Detector installation kit consists of;
1 x 154-0258 Battery Detector Unit
1 x 5 Way Panduit (approx 500mm to 1m)
1 x 1 metres Blue Hookup Wire
Installation:
Observe anti-static precautions at all times
1. Power down the FACP, disconnect the batteries
2. Mount the battery detector in an appropriate place
to allow for connection to batteries
3. Remove the Enclosure Lid to allow access to the
EV3000 Battery Detector PCB
4. Connect 27VDC power to CN1 using a 5 way
Panduit or 27VDC to TB1/1 (+27VDC) and TB1/5
(0V).
EV3000 6 Amp Power Supply fault connection.
1. Wire the Common (TB1/2) of the EV3000 Battery
Detector to the Input of the Battery Isolator / Trip
Switch (See Figure 1)
2. Wire The N/O (TB1/3) of the EV3000 Battery
Detector to the 6 Amp Power Supply Circuit
Breaker terminal, (CB TB2/8). (See Figure 1)
EV3000 16 Amp Power Supply fault connection.
1. Remove the Wire from the Battery Monitoring Fuse
(250mA) and wire to the N/C (TB1/4) of the
EV3000 Battery Detector. (See Figure 2)
2. Connect the supplied hookup wire from the Battery
Monitoring Fuse (250mA) to the common (TB1/2)
of the EV3000 Battery Detector. (See Figure 2)
Final Operation
1. Power up the FACP, connect the batteries and test
by disconnecting the Battery and ensuring a Fault
is generated.
BATT.
08/11/11
BRDEV3BDB1-
DC SUPPLY
FAULT
+27V
COM
N/O
N/C
0V
PRIMARY
TXFR
ZD1
ZD2
U1
RL1
R2
R3
R4
R5
R1
R11
R12
R6
R10
R9
R8
R7
Q1
M1
D1
D2
D3
C4
C3
C1
C2
C7
C6
C5
T
B1
TB2
CN1
Battery 2
12Volts
Battery 1
12 Volts
+
-
-
+
E
AC
AC
C.B
BAT
8V
27V
0V
CURRENT
CURRENT
SET
VOLTS
SET
SET
VOLTS
SET
E
POWER
A.
C
. F
U
SE
MAINS
B
RI
DG
E
+
-
AC
AC
D.C. FUSE
ON
AB
EV
SUPPLY
API 543 E
RE
CT
.
F1
BZ1/1
R7
2
D3
5
C3
6
R7
3
D3
6
C3
7
D3
7
R7
4
C1
3
+
C3
2
Q10
Q11
Q12
C1
2
C2
8
C27
C11
C1
4
R2
2
Z
D1
C3
8
RV3
C1
++++++
C4
C2
C1
9
D1
3
D16
+
C3
5
+
C3
4
S
C1
C 30
C5
++++++
C3
RV1
T3
BZ1/2
B1
T
B1
SI
L1
IC2
IC3
CN
2
CN1
+
+
C2
4
+
C2
9
R50
R3
4
IC4
C2
6
+
+
C18
+
C31
ZD3
TB2
T2
T1
D9
D34
Q15
D22
M2
M1
R63
R62
D29
D28
D32
D23
D27
R5
4
R55
ZD4
ZD2
R58
R30
R2
9
L2
R56
R1
4
R13
L1
D30
R12
C22
C23
C1
6
RV5
b
c
e
Q3
b
c
e
Q4
D1
4
D12
D11
D10
C20
RV
4
RV2
+
+
C1
0
D5
D4
D6
D3
D1
b
c
e
Q1
b
c
e
Q2
D7
C8
C7
IC1
D2
+
+
C1
5
+
C1
7
+
C9
+
C25 D17
D19
D20
D15
e
c
b
Q5
e
c
b
Q6
R4
4
+
C33
R51
R33
LED
1
R45
T
H1
C2
1
P1
P2
CN3
D24
D25
1
2
3
LK1
+
C6
D21
D18
D8
R5
7
R69
R5
9
R64
R31
R39
R23
R3
2
R1
5
R1
6
R49
R18
R35
R36
R37
R38
R2
0
R4
0
R2
5
R4
2
R43
R11
R10
R9
R8
R7
R6
R5
R4
R3
R2
R1
R1
9
R68
R24
R6
5
R48
R46
R6
6
R17
R47
R2
1
R2
6
R61
R71
R2
8
R5
3
R52
R41
R27
R67
R6
0
F2
0V
24V
8V
API-466
06/11/06
A
6
TB1
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
CN1
CN2
CN3
CN4
CN5
CN6
CN7
CN8
CN9
TO AND FROM
AMPLIFIER RACK
BATTERY
ISOLATOR / TRIP
SWITCH (MAIN)
AUX
CONTACT
Figure 1: EV3000 6 Amp Power Supply