background image

ADVANCED WARNING

SYSTEMS

 

Integrated Base Loop Sounder 
Installation Guide

 

Item Numbers: 201-0110 
                           201-0111 

 

MAN2775-3 

N1236

 

Page 3 

WORLD LEADER OF INNOVATIVE SOLUTIONS IN FIRE DETECTION AND ALARM SYSTEMS 

Ampac Technologies Australia

 Tel: +61 8 9201 6100 

Europe

 Tel: +44 (0) 1302 833 522 

New Zealand

 Tel: +64 9 443 8072 

www.ampac.net

  

 

Address DIL Switch Settings 

 

DIL switch setting 

DIL switch setting 

DIL switch setting 

DIL switch setting 

DIL switch setting 

Addr 

1234567 

Addr 

1234567 

Addr 

1234567 

Addr 

1234567 

Addr 

1234567 

1000000 

26 

0101100 

51 

1100110 

76 

0011001 

101 

1010011 

0100000 

27 

1101100 

52 

0010110 

77 

1011001 

102 

0110011 

1100000 

28 

0011100 

53 

1010110 

78 

0111001 

103 

1110011 

0010000 

29 

1011100 

54 

0110110 

79 

1111001 

104 

0001011 

1010000 

30 

0111100 

55 

1110110 

80 

0000101 

105 

1001011 

0110000 

31 

1111100 

56 

0001110 

81 

1000101 

106 

0101011 

1110000 

32 

0000010 

57 

1001110 

82 

0100101 

107 

1101011 

0001000 

33 

1000010 

58 

0101110 

83 

1100101 

108 

0011011 

1001000 

34 

0100010 

59 

1101110 

84 

0010101 

109 

1011011 

10 

0101000 

35 

1100010 

60 

0011110 

85 

1010101 

110 

0111011 

11 

1101000 

36 

0010010 

61 

1011110 

86 

0110101 

111 

1111011 

12 

0011000 

37 

1010010 

62 

0111110 

87 

1110101 

112 

0000111 

13 

1011000 

38 

0110010 

63 

1111110 

88 

0001101 

113 

1000111 

14 

0111000 

39 

1110010 

64 

0000001 

89 

1001101 

114 

0100111 

15 

1111000 

40 

0001010 

65 

1000001 

90 

0101101 

115 

1100111 

16 

0000100 

41 

1001010 

66 

0100001 

91 

1101101 

116 

0010111 

17 

1000100 

42 

0101010 

67 

1100001 

92 

0011101 

117 

1010111 

18 

0100100 

43 

1101010 

68 

0010001 

93 

1011101 

118 

0110111 

19 

1100100 

44 

0011010 

69 

1010001 

94 

0111101 

119 

1110111 

20 

0010100 

45 

1011010 

70 

0110001 

95 

1111101 

120 

0001111 

21 

1010100 

46 

0111010 

71 

1110001 

96 

0000011 

121 

1001111 

22 

0110100 

47 

1111010 

72 

0001001 

97 

1000011 

122 

0101111 

23 

1110100 

48 

0000110 

73 

1001001 

98 

0100011 

123 

1101111 

24 

0001100 

49 

1000110 

74 

0101001 

99 

1100011 

124 

0011111 

25 

1001100 

50 

0100110 

75 

1101001 

100 

0010011 

125 

1011111 

 

 

 

 

 

 

 

 

126 

0111111 

 

Testing: 

Testing is initiated from the control panel and should last for at least 5 seconds.  

Note 3:

 

Output bit 0 is set to 1 on two polling cycles to switch the sounder on. 

Commissioning:

 It is important that the Integrated Base Sounder be fully tested after installation therefore, create an 

alarm situation and ensure the sound level is sufficient for the working environment. 

Note 4:

 

An XP95 Test Set may be used to carry out functional testing of individual units and data integrity tests of an 

entire system. 

Summary of Contents for AS1670.4

Page 1: ... Remote LED Address Output Level Setting Group Address Setting NOT USED Volume Control L1 L2 EARTH VE VE VE VE R R E Detector Xpert Card IN OUT Figure 1 Integrated Base Loop Sounder Wiring Installation Observe anti static precautions at all times 1 The sounders may be secured to a standard conduit box or surface mounted if there is access through the mounting surface for cabling If a detector is f...

Page 2: ...8 4 16 32 64 49 1 2 8 4 16 32 64 50 1 2 8 4 16 32 64 51 1 2 8 4 16 32 64 52 1 2 8 4 16 32 64 53 1 2 8 4 16 32 64 54 1 2 8 4 16 32 64 55 1 2 8 4 16 32 64 56 1 2 8 4 16 32 64 57 1 2 8 4 16 32 64 58 1 2 8 4 16 32 64 59 1 2 8 4 16 32 64 60 1 2 8 4 16 32 64 61 1 2 8 4 16 32 64 62 1 2 8 4 16 32 64 63 1 2 8 4 16 32 64 64 1 2 8 4 16 32 64 65 1 2 8 4 16 32 64 66 1 2 8 4 16 32 64 67 1 2 8 4 16 32 64 68 1 2 ...

Page 3: ...1111011 12 0011000 37 1010010 62 0111110 87 1110101 112 0000111 13 1011000 38 0110010 63 1111110 88 0001101 113 1000111 14 0111000 39 1110010 64 0000001 89 1001101 114 0100111 15 1111000 40 0001010 65 1000001 90 0101101 115 1100111 16 0000100 41 1001010 66 0100001 91 1101101 116 0010111 17 1000100 42 0101010 67 1100001 92 0011101 117 1010111 18 0100100 43 1101010 68 0010001 93 1011101 118 0110111 ...

Page 4: ...ol Protocol bit use Output Bit Function Input Bit Function Not Used 2 group mode 2 group mode confirmed For information only 1 off 1 group 0 on 0 individual ALERT 1 pulsed mode 1 pulsed mode confirmed 1 on 1 on 0 off 0 off EVACUATION 0 continuous mode 0 continuous mode confirmed 1 on 1 on 0 off 0 off Fault Finding Problem Possible Cause No response or missing Incorrect address setting Incorrect lo...