background image

Specifications 

0.6Nm DC motor for Cellular/Honeycomb shades

Compatible with AMP

 external battery pack

Approximately 500 up/down cycles per each full charge

3 motor speed settings: 34, 40 or 50rpm

Sound level ~48dB

5 year warranty

AMPCEL

-0.6/50

Programming Guide

Upgrade to the industry’s most advanced Motor Program:

AMP

 Motorization

 features 2-way technology with superior value

and innovation paired with a smart, seemless user interface.

AMP 2 color logo: PMS Cool Gray 2 & PMS 306 Blue

Summary of Contents for AMPCEL-0.6/50

Page 1: ...each full charge 3 motor speed settings 34 40 or 50rpm Sound level 48dB 5 year warranty AMPCEL 0 6 50 Programming Guide Upgrade to the industry s most advanced Motor Program AMP Motorization features...

Page 2: ...afety Instructions AMPCEL 0 6 50 Overview P1 Button Instructions AMP Remote Overview Initial Set up Adjust Limits Favorite Position Add or Remove Additional Remote Adjust Motor Speed Roller or Sheer M...

Page 3: ...y turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation...

Page 4: ...g 5V charger most phones charger is 5V During operation when the motor starts the buzzer will beep 10 times indicating a low voltage alarm and needs to be charged During operation the voltage was dete...

Page 5: ...please charge motor for 6 hours using a 5V charger During operation if the voltage is detected to be too low the battery stops running and needs to be recharged 1 Fields of Application 2 Motor Head B...

Page 6: ...n Reset To Factory Settings Approx 2 sec Happening as you press for 2 seconds Happening as you press for 1 second Happening as you press for 6 seconds Happening as you press for 10 seconds Happening a...

Page 7: ...lect a lower channel b Press button on the remote to select a higher channel Hide Unused Channels a Press and Hold about 3 sec and buttons simul taneously until remote control displays C channel b Pre...

Page 8: ...tion to disable the following commands remote will show L lock Change Motor Direction Setting the Upper and Lower Limit Adjust Limit Roller Mode or Sheer Mode c Move the switch to Unlock position to a...

Page 9: ...then press Stop button when it is in the desired lower limit b Press and hold about 2 sec Down and Stop buttons simultaneously until motor jog x2 a Press P1 button about 2 sec on the motor head until...

Page 10: ...ress and hold about 5 sec Down and Stop buttons simultaneously until motor jog x1 b Use Down button to lower the shade to the desired lowest position and use Up or Down button to do the final adjustme...

Page 11: ...ess one P2 button on the back of remote control until motor jog x1 c Press and hold about 2 sec Stop button until motor jog x1 d Once more press and hold about 2 sec Stop button until motor jog x2 2 S...

Page 12: ...remote control press one P2 button until motor jog x1 c On the New remote control press one P2 button until motor jog x2 Action on Remote Control Action on Remote Control Motor Response Motor Respons...

Page 13: ...g x2 2 Deceleration Speed a Press one P2 button until motor jog x1 b Press Down button until motor jog x1 c Once more press Down button until motor jog x2 Action on Remote Control Action on Remote Con...

Page 14: ...out 2 sec Stop button until motor jog x2 2 Sheer Shade Mode jog movement after a short press continue movement after a long press a Press and hold about 5 sec Up and Down buttons simultaneously until...

Page 15: ...s Place all other motors into sleep mode ref to P1 button instructions Cannot program a single motor multiple motors respond Multiple motors are paired to the same channel A M P C E L 0 6 5 0 P R O G...

Reviews: