Amos ATP 140 Operation Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

ATP 140 

 

Tissue Processor 

Operation Manual 

 

 

 
 

www.amos-scientific.com

 

 

 

AMOS SCIENTIFIC PTY.LTD. ABN:37 159 778 140

 

Summary of Contents for ATP 140

Page 1: ...ATP 140 Tissue Processor Operation Manual www amos scientific com AMOS SCIENTIFIC PTY LTD ABN 37 159 778 140...

Page 2: ......

Page 3: ...Processor and the matters needing attention concerning safety Please carefully read this manual before use so that you can understand its performance better and make full use of the functions If you h...

Page 4: ......

Page 5: ...and characteristics 2 2 2 Distribution of Liquid Tank 4 2 3 Structure Breakdown Diagram 5 3 Operation Guide 6 3 1 Key instruction 6 3 2 Screen LCD display instruction 9 3 3 Operation 11 4 Trouble sho...

Page 6: ......

Page 7: ...aleful liquid Leak in proof degree Normal enclosed equipment without liquid leak in proof Working system Continuous running Installation environment 1 More than 20cm of space around the equipment for...

Page 8: ...cells 2 1 Quantity of hanging basket 2 Each basket can hold 72 standard embeddingcassettes 42x29x6mm L W H Quantity of liquid tank 10 Quantity of paraffin tank 4 at the last four tanks Capacity of tan...

Page 9: ...ct a power supply to keep instrument enter into protection state the basket will stay in the current processing tank and will continue running the program after power on Agitation frequency two basket...

Page 10: ...ly if the two baskets all stay well in the Tank 1 and 2 the instrument will run the second program first and then run the first program The system provides eight programs 4 groups be edited Note when...

Page 11: ...6 Power switch 7 Power socket 8 Activated Carbon filter 9 Filter 10 Power supply 11 Control Box 12 Rear cover board 13 Structure Breakdown Diagram 1 hanging basket 2 Sealing cover 3 Oven type heater 4...

Page 12: ...y 3 Display Panel 3 1 Key instruction StandbyIt can be activated in Auto or Manualmode press this key topause running or continue running But when the instrument is running a procedure press this key...

Page 13: ...ain menu when it is in Manual mode press this key the machine will enter into Auto mode the hanging basket arm runs automatically and the temperature begins to rise and stir up and down in 15 seconds...

Page 14: ...n main menu when the machine standby in Auto mode or end running The operator can press this key into manual mode The parameters are displayed as the following in the screen MagnetIt can be activated...

Page 15: ...splay the parameters set tank number temperature and time in each step In Edit programwindows the operator can set required value by when the icon is flickering and then press program key to set tank...

Page 16: ...number actual temperature the rest time to finish this step heating state on off and the state of basket waiting rock vat block standby ending and so on As the picture showed the basket is running to...

Page 17: ...ill lead the user to set the corresponding value by Note The first step of Program 1 Program 3 Program 5 Program 7 is tank number 01 The first step of Program 2 Program 4 Program 6 Program 8 is tank n...

Page 18: ...Operation Auto Mode 1 In the main menu select the running program by Attention Program 1 and 2 is in a group Program 3 and 4 is in a group Program 5 and 6 is in a group Program 7 and 8 is in another...

Page 19: ...cedure For example if the running procedure number is program 1 the insert procedure number cannot be programmed 1 3 5 7 it should be chosen from program 2 4 6 8 That could avoid the running time end...

Page 20: ...me as the basket stayed into Press Run go to running But regardless of the insert by which way the largest number of programs can run at the same time is two programs which cannot be same as the odd o...

Page 21: ...s broken Change a new temperature sensor After turn the instrument on the temperature displays in non numerical Damaged driver of stepping motor Repair by Factory or distributor Tank cover would not b...

Page 22: ...o them which will cause leakage a Keep the upper side of the cover the place magnet contact clean and without obstruction b Keep the black bottom of the magnet suck box clean and without obstruction c...

Page 23: ...an be provided high efficiency battery to ensure that the program is completely executed without interruption under the power status of power failure Note Prior to instrument operating please ensure t...

Page 24: ...18 ATP 140 Tissue Processor Ver AMOSATP140OP20151010 6 Schematic Diagram...

Page 25: ...19 ATP 140 Tissue Processor Ver AMOSATP140OP20151010...

Page 26: ...20 ATP 140 Tissue Processor Ver AMOSATP140OP20151010 7 Wiring Diagram...

Page 27: ...essories list No Accessory Name Qty Notes 1 Tissue processor 1 set 2 Power cord 2pcs 3 Fuse 4pcs 4 Basket grid 2 sets 6pcs grid for small tissue 6 pcs grid for large tissue 12pcs grid for customer spe...

Page 28: ...Published by AMOS SCIENTIFIC PTY LTD 7 Gabrielle Court Bayswater North VIC 3153 Melbourne Australia Tel 61 410190188 Fax 61 410190188 ABN 37 159 778 140 www amos scientific com...