10.0.1 Ge ne ral in for ma ti on
•
Ob serve the safety in for ma tion
•
Only qual i fied and authorised per sons may carry out re -
pair work (me chan ics spe cial is ing in con struc tion and
ag ri cul tural ma chin ery).
•
In case of faults, the op er at ing and main te nance in struc -
tions must be re ferred to for cor rect op er a tion and main -
te nance.
•
If the cause of the fault can not be lo cated or rem e died, an
authorised Ammann Ser vice Cen tre should be con tacted.
•
Al ways first check the most likely causes (fuses, LEDs,
etc.).
A
1
2
0
2
0
0
0
0-
2
H
b
m
G
g
n
ut
h
ci
dr
e
V
n
n
a
m
m
A
8
1
0
2/
8
0
10. Trou ble shoot ing
9.0.2 Fault tab le
Pos si ble cause
Rem edy
Re marks
En gine does not start
Speed con trol le ver in «STOP»-po si tion
No fuel
–
Tank run dry
–
Fuel fil ter blocked
–
Fuel valve «
OFF
»
–
De fec tive feed pump
Oil pres sure lost
Com pres sion too low
Set le ver to «START»-po si tion
Add fuel
Re new fuel fil ter
Move le ver to «
ON
» po si tion
Func tion must be checked
Check en gine oil level
Con tact a Ammann-ser vice sta tion
HONDA
En gine switch «
OFF
»
Choke «
OPEN
»
Spark plug faulty, fouled or im prop erly
gap ped
Spark plug wet with fuel (flooded en gine)
Turn en gine switch to «
ON
» po si tion
Move le ver to «
CLOSE
» po si tion
Gap or re place spark plug
Dry and re in stall spark plug
HONDA
HONDA (Un less the en gine is warm)
HONDA
HONDA (Start en gine with throt tle le ver in «
MAX
» po si tion)
En gine stops by it self dur ing reg u lar op er a tion
Fuel sup ply is in ter rupted
–
Tank run dry
–
Fuel fil ter blocked
–
De fec tive feed pump
Oil pres sure lost
Me chan i cal de fects
Add fuel
Re new fuel fil ter
Func tion must be checked
Check en gine oil level
Con tact a Ammann-ser vice sta tion
Re duced en gine per for mance
Fuel sup ply is ob structed
–
Tank run dry
–
Fuel fil ter blocked
–
Tank vent ing is in ad e quate
–
Leaks at pipes un ions
Air cleaner blocked
In cor rect valve clear ance
Too much oil in en gine
Too much oil in ex citer
De fault in hy drau lic sys tem
Add fuel
Re new fuel fil ter
En sure that tank is ad e quately vented
Check threaded pipe un ions
Re move dirt from air cleaner
Ad just valve clear ance
Cor rect the en gine oil level
Check ex citer oil level
Con tact a Ammann-ser vice sta tion
En gine runs, ma chine does not move for ward
In suf fi cient V-belt ten sion
V-belt bro ken
Cen trif u gal clutch lin ing worn
Too much oil in ex citer
De fault in hy drau lic sys tem
Re ten tion V-belt
Re place V-belt
Re place lin ings and springs
Check ex citer oil level
Con tact a Ammann-ser vice sta tion
97