Power Supply Modules AN xx / AN xxF 

 
 
 
 

Technical manual 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
Rights reserved to make technical changes 
 
 

4400.1E 

Part-No.: 25747 

 

AMKASYN

 

VARIABLE  SPEED  DRIVES

 

 

Arnold Müller, Antriebs- und Steuerungstechnik GmbH & Co.KG, D-73230 Kirchheim/Teck, 
Tel.: 07021/50 05-0, Telefax: 07021/50 05-176

 

Summary of Contents for AMKASYN AN 10

Page 1: ... Power Supply Modules AN xx AN xxF Technical manual Rights reserved to make technical changes 4400 1E Part No 25747 AMKASYN VARIABLE SPEED DRIVES Arnold Müller Antriebs und Steuerungstechnik GmbH Co KG D 73230 Kirchheim Teck Tel 07021 50 05 0 Telefax 07021 50 05 176 ...

Page 2: ... Power Supply modules AN xxF specification FERRAZ NH fuses 6 4 DIMENSIONS POWER SUPPLY MODULES AN XX AN XXF 7 5 FRONT VIEW POWER SUPPLY MODULES AN XX AN XXF OPTION NEOZED FUSES 8 6 BLOCK DIAGRAM AND CONNECTION DRAWING POWER SUPPLY MODULES AN XX AN XXF 11 7 WIRING POWER SUPPLY MODULES AN XX AN XXF 12 8 FUNCTIONAL DESCRIPTION POWER SUPPLY MODULES 13 9 SIGNAL DESCRIPTION OF POWER SUPPLY MODULES 14 10...

Page 3: ... t a t u s c o d e c a ll S t a t u s c o d e c l o c k C a m R e f L S P o w e r b u s P o w e r s u p p l y m o d u l e o p t i o n C e n t r a l m o d u l e I n v e r t e r m o d u l e A n a l o g o u t p u t s 1 2 b i t 1 0 V B i n a r y o u t p u t s o p t i c a l l y i s o l a t e d B i n a r y i n p u t s o p t i c a l l y i s o l a t e d S q u a r e w a v e p u l s e i n p u t B i n a r y ...

Page 4: ...rs are performed diligently by trained and experienced specialists Drive system parameters may only be set or modified by the machine manifacturer Entry of non conforming parameter values is effecting the drive behaviour and increasing the risk of accidents and damage Each time before working on the AMKASYN drive system Interrupt power supply using the MASTER SWITCH Working under voltage is danger...

Page 5: ...nt 16 A 32 A 64 A 96 A Main fuses F1 F2 F3 Type 20 A NEOZED D02 gL IEC 269 35 A NEOZED D02 gL IEC 269 80 A NEOZED D03 gL IEC 269 100 A NEOZED D03 gL IEC 269 Miniature fuses F4 F5 F6 F7 F8 Make size M4A 400V FERRAZ R98248 6 3 x 32 Recommended cable cross sections mm2 AWG Cable cross sections according to Conductors Table 53 2 UL508C Use copper wires 75 C only X01 Power input X06 Connection AN AZ 3 ...

Page 6: ...RAZ Y 094827 Miniature fuses F4 F5 F6 F7 F8 Make Size FF 6 3A 500V FERRAZ A 085445 6 3 x 32 Recommened cable cross sections mm2 AWG X01 Power input X06 Connection AN AZ 3 x 400V power output X05 Connection AN AZ Charging circuit X13 Fan supply 4 x 2 5 AWG12 3 x 2 5 AWG12 5 x 1 AWG16 2 x 0 75 AWG18 4 x 10 AWG8 3 x 6 AWG10 5 x 1 AWG16 2 x 0 75 AWG18 4 x 25 AWG4 3 x 16 AWG4 5 x 1 AWG16 2 x 0 75 AWG18...

Page 7: ...57 E 14 06 0 275 6 8 0 27 3x45 7 18 0 708 7 8 0 3 7 15 0 59 Y X Ansicht View Ansicht View 0 275 AN10 AN10F 90 3 54 170 6 69 60 2 36 415 16 34 415 16 34 595 25 43 400 15 75 400 15 75 580 22 84 358 14 09 358 14 09 538 21 18 Type A B C D E AN20 AN20F AN40 AN40F AN60 AN60F 90 3 54 170 6 69 60 2 36 140 5 51 140 5 51 595 25 43 580 22 84 538 21 18 15 0 59 ...

Page 8: ...odules AN xx AN xxF option NEOZED fuses AN F1 F2 F3 Input power fuses To AZ module X25 F4 F5 F6 Fuses for switch mode power supply charging circuit F7 F8 Fuses for fan main contactor To AZ module X33 Input power 3x400V Fan main contactor supply 230V DC BUS supply behind main contactor Aux contact n c main contactor ...

Page 9: ...0 60Hz 230 VAC 50 60Hz FF6 3A 500VAC FERRAZ A 85445 F1 F2 F3 Input power fuses NH to AZ module X25 X14 Aux contact n c X01 Input power X33 F5 F5 F6 Fuses for switch mode power supply charging circuit F7 F8 Fuses for fan main contactor 3x400 480VAC X03 Fan main contactor 230V X06 DC BUS supply behind main contactor main contactor Fuse rating Fuse type to AZ module ...

Page 10: ...x 480 VAC 50 60Hz 230 VAC 50 60Hz FF6 3A 500VAC FERRAZ A 85445 F1 F2 F3 Input power fuses to AZ module X25 X14 Aux contact n c X01 Input power X33 F5 F5 F6 Fuses for switch mode power supply charging circuit F7 F8 Fuses for fan main contactor 3x400 480VAC X03 Fan main contactor 230V X06 DC BUS supply behind main contactor main contactor Fuse rating Fuse type to AZ module FERRAZ ...

Page 11: ...2 F 3 F 1 F 7 4 A F 8 4 A Z S M P S c h a r g i n g c i r c u i t s u p p l y M a i n c o n t a c t o r O n I n t e r r u p t i o n f o r m a i n c o n t a c t o r b y c u s t o m e r F a n P o w e r c i r c u i t C h a r g i n g c i r c u i t L i n e r e a c t o r u 4 P o w e r i n p u t 3 x 4 0 0 V C o i l v o l t a g e m a i n c o n t a c t o r 2 3 0 V f r o m v e r s i o n 0 1 0 0 A u x c o n ...

Page 12: ...modules AN xx AN xxF ENTLADEZEIT 1 MIN 1 5P 12P 12N AZB QUE 2 3 4 5 6 7 8 AZ R01 X77 OPTIONEN 1 2 3 4 AZR AZ AN PE bar Brake resistor Fan supply 230V 3x400V input power X24 PTC brake resistor X32 Square wave pulse input X77 AZ R01 RS232C X31 Binary inputs X29 Analog outputs X30 Binary inputs to AZB control panel ...

Page 13: ...tionally integrated which guarantees the conformity of the radio interference voltage s limiting values according to class A EN 5501 for the AMKASYN system It must however be provided that cabling shielding and earthing are executed as instructed The AC voltage for the fans in the modules 230V see AN specifications must be provided by the customer at the terminals X03 F7 and F8 fuse the fan circui...

Page 14: ...drive system on the power side from the power supply by an external safety circuit The input of the switched mode power supply is not interrupted in this case and axis specific data is retained Input RF Inverters On must be switched off before or simultaneously with the interruption of ES1 ES2 The drive system goes to fault without this measure It must be noted that regenerative braking is possibl...

Page 15: ...7 Unscrew PE connections at AN module 8 Loosen module fastening screws at the mounting panel 9 Slightly lift the module and take it out towards you 10 Insert the new AN module with the same specification lower it and securely tighten the fastening screws 11 Securely tighten PE connections at AN module 12 Insert and latch fan connector X33 at AZ module 13 Insert plug in terminal block X25 at AZ mod...

Page 16: ...e the right to change the contents of the documentation and the availability of products at any time without prior notice Service Tel 49 0 7021 5005 191 Fax 193 Business Hours Mo Fr 7 30 16 30 On weekends and holidays calls are forwarded to an emergency response number by the automated answering system To assure a fast and accurate response to solve customer problems we ask for your cooperation in...

Reviews: