rru-wc1101_g_en_100
RRU-WC/110x
WTB / CAN gateway
Operation manual
Version 1.00
Page 1: ...rru wc1101_g_en_100 RRU WC 110x WTB CAN gateway Operation manual Version 1 00...
Page 2: ...xt all pages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must no...
Page 3: ...7 Communication lines 17 7 1 WTB 17 7 1 1 WTB line state indication 18 7 2 Ethernet 19 7 2 1 Ethernet line state indication 19 7 3 CAN 20 7 3 1 CAN line status indicator 20 8 Indications and settings...
Page 4: ...1101_g_en_100 pdf Author Ji B ezina Revision Date Changes 100 29 6 2012 New document Related documentation 1 WTB CAN Gateway Programming manual file wtb c11_1_ms_en_xxx pdf 2 i a i n e in i e in ne fi...
Page 5: ...efinition of used abbreviaions Bus Administrator Electrical Middle Distance Medium Attachment Unit Multifunction Vehicle Bus Message Data Process Data To Be Defined Train Communication Network Wire Tr...
Page 6: ...tion 1 and 2 are disconnected Terminating resistors are connected in both directions Intermediate Setting The node in this state is physically connected in the middle of WTB line The main MAU channel...
Page 7: ...CAN bus communication protocol meets the requirements of IEC 61375 3 3 2012 Gateway is supplied from factory with loader only Prior to first use must be loaded into gateway the appropriate application...
Page 8: ...V AC 1 minute Data transmission rate 100 Mbps Recommended cabling STP CAT5 Maximum segment length 100 m Connection point RJ45 connector according to IEEE802 3 Standards IEC61375 1 2007 Galvanic separa...
Page 9: ...rava_modular_system_m_en_100 pdf 1 HP horizontal pitch 0 2 inch 5 08 mm 1U rack unit 1 75 inch 44 45 mm Unit overall mass of plastics 212 73 g Included mass of self extinguishing plastics 212 73 g Dev...
Page 10: ...and C2 Class WTB gateway meets the SWSIL0 classification according to EN 50128 2011 Railway applications Communications signalling and processing systems Software for railway control and protection sy...
Page 11: ...RRU WC 110X 11 28 rru wc1101_g_en_100 4 1 Dimensions All dimensions are stated in mm 142 185 128 168 112 139 Fig 1 Physical dimensions of WTB gateway...
Page 12: ...owing drawing symbol is recommended for RRU WC 1101 WTB gateway X1 24 V WAGO 769 663 RRU WC 1101 X2 X3 X4 X5 X6 Ethernet RJ45 WTB A1 D sub DE 9 WTB A2 D sub DE 9 WTB B1 D sub DE 9 WTB B2 D sub DE 9 X7...
Page 13: ...agram FPGA Power supply DDR2 WTB interface Ethrenet interface 5 V ss X2 X3 X4 X5 X6 X7 X8 WTB A1 WTB A2 WTB B1 WTB B2 CAN1 CAN1 Ethernet 2 5 V ss 1 8 V ss 1 2 V ss CAN interface X1 Power 24 V ss Power...
Page 14: ...ity test 1000 MHz to 2100 MHz 10 V m EN 61000 4 3 2006 Electromagnetic compatibility EMC Part 4 3 Radiated radio frequency electromagnetic field immunity test 2100 MHz to 2500 MHz 5 V m EN 61000 4 4 2...
Page 15: ...al testing Part 2 2 Test B Dry heat Complies EN 60068 2 30 1999 Environmental testing Part 2 Tests Test Db and guidance Damp heat cyclic Complies IEC61375 1 2007 Ed 2 0 Electric railway equipment Trai...
Page 16: ...supply WTB gateway RRU WC 1101 can be powered by 24 V DC vehicle onboard network Connector type WAGO 769 663 X COM plug Connector Pin Signal Meaning X1 1 PE Unit chassis 2 GND Power supply ground 3 Vc...
Page 17: ...lines in End Setting state is solved by internal terminators connecting of whose is provided by software Connector type D sub DE 9 plug Connector Pin Signal wiring X3 WTB A1 X5 WTB A2 1 WTB line posi...
Page 18: ...de state Following table describes meaning of the individual LEDs Fig 4 Front panel LEDs WTB LEDs LED Color Meaning TL1 Green Trusted Line direction 1 TL2 Green Trusted Line direction 2 RX1 Green Data...
Page 19: ...RJ45 according to IEEE802 3 Connector Pin Signal wiring X2 1 Tx 2 Tx 3 Rx 4 5 6 Rx 7 8 1 8 Fig 5 Ethernet line connector 7 2 1 Ethernet line state indication Indication of Ethernet line state is provi...
Page 20: ...nically separated ground 7 CAN1 line positive wire 8 Not used 9 Not used Connector type D sub DE 9 socket Connector Pin Signal wiring X8 CAN1 1 Not used 2 CAN1 line negative wire 3 Galvanically separa...
Page 21: ...ss Following cases can occur when gateway is in Error status WTB configuration is missing or can not be read Invalid Ethernet configuration Start of an application failed Occurence of another error in...
Page 22: ...ion To restore the factory setting press and hold the RSTR button while gateway starts up First the S1 LED goes ON and after cca 5 sec starts to blink Release the button when S1 LED starts to blink Af...
Page 23: ...rews with M3 5 thread not included In this case is necessary to remove from the front panel four plastic grommets together with four screws M3 The metal box with gateway can be mounted arbitrarily int...
Page 24: ...y important to ensure that ambient temperature does not exceed the allowed limits At the same time must be ensured that heat radiating equipments located nearby does not cause exceeding of these maxim...
Page 25: ...h local installation earthing terminal Cross section of supplying conductors must be at least 0 75 mm2 All cabling must be carefully tied by cable ties to avoid the excessive connector pulling or pryi...
Page 26: ...ounterpart D sub DE 9 pin M3 crimping pins metal cap socket CAN 09M MC A Protikus konektoru linky WTB D sub DE in M im va me a i y vid i e 10 2 Completion Part Quantity WTB gateway 1 Power supply conn...
Page 27: ...fter time with regard to way of usage it is necessary to remove dust from device The WTB gateway can be cleaned in cut off state and disassembled by dry paintbrush or fine brush alternatively by vacuu...
Page 28: ...posal The disposal of WTB gateway is subject to the regulations on handling electrical waste Equipment must not be disposed together with common public waste It must be delivered to places specified f...