Amit RB-MVB/AN02 Operation Manual Download Page 1

 

rb-mvban02_g_en_100 

RB-MVB/AN02 

 

MVB analyser 

Operation manual 

Version 1.00 

 

Summary of Contents for RB-MVB/AN02

Page 1: ...rb mvban02_g_en_100 RB MVB AN02 MVB analyser Operation manual Version 1 00...

Page 2: ...ages must be copied without any changes 2 All redistributed copies must retain the AMiT spol s r o copyright notice and any other notices contained in the documentation 3 This document must not be dis...

Page 3: ...nformity assessment 14 6 1 Other tests 15 7 Power supply 16 8 Communication lines 17 8 1 MVB ESD 17 8 2 MVB EMD 18 8 2 1 MVB line state indication 19 8 3 Ethernet 20 8 3 1 Ethernet line state indicati...

Page 4: ...History of revisions Document name rb mvban02_g_en_100 pdf Revision Date Author of change Changes 100 4 10 2016 Petrovsk J New document Related documentation 1 RB MVB AN02 MVB analyser Programmers ma...

Page 5: ...n_100 1 Definition of used abbreviaions Bus Administrator Electrical Middle Distance Medium Attachment Unit Multifunction Vehicle Bus Message Data Process Data To Be Defined Train Communication Networ...

Page 6: ...with implementing of transformer coupling for galvanic isolation EMD medium is used for up to 32 nodes and for distances to 200 m Electrical Short Distance Type of physical interface of the MVB line...

Page 7: ...gering Device is supplied from factory only with loader Before first use all required domains must be loaded into device see Programming manual 2 MVB interface in EMD and ESD version doubled line 1 Et...

Page 8: ...ation rate 10 100 Mbps Galvanic isolation Yes Galvanic isolation strength 500 V AC 1 minute Connection point RJ45 connector according to IEEE802 3 Recommended cabling STP CAT5 Maximum segment length 1...

Page 9: ...A mounting to vehicle body Permissible supplying voltage drop outs duration max 10 ms Class S2 according to Chapter 3 1 1 2 of EN 50155 2007 For supply voltage switching are permissible conditions of...

Page 10: ...00 10 30 4 1 Dimensions xxxxxxx S N WEIGHT 0 87 kg DATE 09 06 2015 MAC xx xx xx xx xx xx HiPot HiPot OK TEST OK JE LDR 1 0 POWER 24 V DC 0 6 A TYPE RB MVB AN02 50 187 203 228 6 78 113 Fig 1 RB MVB AN0...

Page 11: ...ecommended drawing symbol Following drawing symbol is recommended for RB MVB AN02 analyser RB MVB AN02 PWR PE GND Vcc X1 1 2 3 X2 Ethernet X4 MVB ESD X3 MVB ESD X5 Trigger X7 MVB EMD X6 MVB EMD Fig 2...

Page 12: ...yser RB MVB AN02 is fitted with producer type label on its side xxxxxxx S N WEIGHT 0 87 kg DATE 09 06 2015 MAC xx xx xx xx xx xx HiPot HiPot OK TEST OK JE LDR 1 0 POWER 24 V DC 0 6A TYPE RB MVB AN02 1...

Page 13: ...xx xx xx xx xx X2 interface MAC address LDR 1 0 Loader version POWER 24 V DC 0 6 A Power supply voltage Consumption WEIGHT 0 87 kg Weight TEST OK xx Routine testing result HiPot HiPot OK HiPot test re...

Page 14: ...4 3 Radiated radio frequency electromagnetic field immunity test 800 MHz to 1000 MHz 20 V m EN 61000 4 3 2006 Electromagnetic compatibility EMC Part 4 3 Radiated radio frequency electromagnetic field...

Page 15: ...ent Shock and vibration tests Complies EN 60068 2 1 2007 Environmental testing Part 2 1 Tests Test A Cold Complies EN 60068 2 2 2007 Environmental testing Part 2 2 Tests Test B Dry heat Complies EN 61...

Page 16: ...r RB MVB AN02 can be powered only by DC power supply 24 V X1 Fig 5 Power supply connector location Connector type WAGO 769 103 021 000 Connector Pin Signal Description X1 1 PE Module chassis 2 GND Pow...

Page 17: ...ting resistors for ESD are included in TRM MVB F ESD and TRM MVB M ESD X3 X4 Fig 6 Location of MVB ESD connectors Connector type D sub DE 9 plug Connector Pin Signal Description X3 X4 1 A Data_P A lin...

Page 18: ...tor type D sub DE 9 socket Connector Pin Signal Description X6 X7 1 A Data_P A line positive wire 2 A Data_N A line negative wire 3 Not used 4 B Data_P B line positive wire 5 B Data_N B line negative...

Page 19: ...EDs LED Colour TA Green TB Green AA Green AB Green DA Yellow DB Yellow MA Green BA Green LED Description TA trusted line line A TB trusted line line B AA activity on line A AB activity on line B DA di...

Page 20: ...r to LAN network X2 Fig 9 Ethernet connector location Connector type RJ45 socket PIN Signal Description 1 Tx Data transmission signal 2 Rx Data reception signal 3 Tx Data transmission signal 4 Not use...

Page 21: ...Following table describes meaning of individual LEDs Fig 11 Detail look on front panel LEDs Ethernet LEDs LED Colour SPD Green ACT Green LED Status Description SPD Lights Communication speed 100 Mbps...

Page 22: ...puts outputs 9 1 Trigger output Analyser RB MVB AN02 is equipped with triggering output with BNC connector Output signal has a 5 V level output impedance is 50 The function is given by the software X5...

Page 23: ...Description PWR Lights Power supply voltage indication RUN Blinks T 2 s Operation status Blinks T 200 ms Error status Lights up permanently Service mode Application program is loaded device works pro...

Page 24: ...After analyser shut down and start up the recently loaded application is launched Factory setting To restore the factory setting press and hold the RESTORE button during unit start up The RUN LED fir...

Page 25: ...25 30 rb mvban02_g_en_100 10 3 Mounting installation rules MVB analyser is intended for mounting on base plate with two 6 mm diameter holes Analyser could be mounted in any position 203 6 Fig 15 Moun...

Page 26: ...RB MVB AN02 Complete unit see chapter 11 1 Completion 11 1 Completion Part Quantity MVB analyser 1 Connector counterpart WAGO 769 103 021 000 1 Insulation testing protocol 1 Certificate of product qu...

Page 27: ...e dimensions are listed in chapter 4 Technical parameters Sticker on the box contains following information Item Description TYPE RB MVB AN02 NETTO 0 90 kg BRUTTO 1 14 kg QTY 1 pc S N Serial number AM...

Page 28: ...ust not exceed 10 kg All load must be evenly spread over the entire upper side of the box Unpacked product must be stored only under the conditions specified in chapter Technical parameters Product ma...

Page 29: ...enance Depending on equipment usage the dust is to be removed occasionally from equipment The equipment can be cleaned by dry soft brush or vacuum cleaner only when turned off and disassembled The mai...

Page 30: ...sal The disposal of electronic equipment is subject to the regulations on handling electrical waste The equipment must not be disposed of in common public waste It must be delivered to places specifie...