43
Installation of PB*4VI509*FT* hob
INSTALLATION
•
prepare a place (an opening) in the table top according to di men sions specified on the
installation drawing (Fig. A),
•
minimal clearance to be left between the appliance and the sides of the ne igh bo uring
cupboards is 50 mm,
•
the installed plate is 50mm high,
•
if the cooking plate is separated from the support cupboard by means of a horizontal pro-
tec ti ve plate, the clearance between the bottom of the enclosure of the cooking plate and
the protective plate has to be at least 25 mm high to ensure free air flow.
• cut a square opening (with at least 80mm side) in the rear part of the protective plate (Fig. C),
•
connect the plate to the mains according to the attached wiring diagram,
•
match the section of the mains cable to the power of the plate (should be done by a qu
-
alified electrician),
•
remove dust from the top, insert the plate into the opening and press hard (Fig.B).
Fig. A
* dimensions valid for PB*4VI511 AFTB*S* hob
600 (750*)
600
50
500
(490*)
518
616 (770*)
50