![amiad Arkal Spin Klin 2 User Manual Download Page 11](http://html.mh-extra.com/html/amiad/arkal-spin-klin-2/arkal-spin-klin-2_user-manual_2932246011.webp)
FILTER TYPE 2" AAF
000616
-
10101
9
/
07.2017
Page
11
of
28
4. Technical Data
Parameters
METRIC
US
Maximum pressure
10 bar (25
C)
145 psi ( 77 °F)
Minimum working pressure
Minimum pressure for back-flush:
400µ-130µ
100µ-70µ
50µ-20µ
1.0
bar
3 bar
3.5 bar
5 bar
14.5 psi
43.5 psi
50.75 psi
72.5 psi
Back-flush water volume
12
–
22 (L)
Per single filter
3.2
–
5.8 (Gl)
Per single filter
Maximum temperature
60 °C (@4 bar )
158 °F (@58 psi)
PH
4-11
4-11
Air Pressure
Equal or higher than the
pressure used for back-
flush.
Equal or higher than
the pressure used for
back-flush.
Construction Materials
Filter Housing & Lid
RPA (Reinforce Polyamide) or RPP (Reinforce Polypropylene)
Disc elements
PP (Polypropylene) or PA (Polyamide)
Backwash valves
RPA (Reinforce Polyamide) or RPP (Reinforce Polypropylene)
Manifolds
PP (Polypropylene)
Seals
NBR or EPDM, (Viton optional)
Control Tubing
PE or PA
Recommendation Air Compressor: 3/4 H.P. + 80L /21Gl Tank.