AMG AMG5804A966G-DF Instruction Manual Download Page 1

AMG Systems Ltd. reserves the right to make changes to this 
document without notice. The information herein is believed to 
be accurate. No responsibility is assumed by AMG for its use.  

Page 1 of 12 

AMG5804A966G-DF Instruction Sheet 
D17400-00.doc 
 

 

 

 

 

AMG5804A966G-DF      

Instruction Manual  

Data Receive Unit with 2 Bi-directional Data Channels, 6 Bi-

directional Audio Channels, 2 Echelon FTT-10A Data 

Channels and 8 Bi-directional Alarms plus Ethernet for a 

Dual Multimode Fibre Link 

 

 

 

 

 

 

 
The 

AMG5804A966G-DF

 is a rackmount data transmit unit designed to transmit and receive 2 data 

channels, 6 audio channels, 2 Echelon FTT-10A data channels and 8 bi-directional alarms over two 
Multimode optical fibres. It also provides full duplex 100Base-T Ethernet connectivity. 
 
The 

AMG5804A966G-DF

 is designed to be powered using an 

AMG2003 

standalone or equivalent 

power supply. The G suffix in the partno. indicates a 3rd party subrack mounting configuration. 
 
The 

AMG5804A966G-DF

 is designed to operate with an 

AMG5803A966-DF 

standalone

 

or

 

AMG5803A966G-DF

 rackmount data receive unit in a point to point configuration.  

 

 

Summary of Contents for AMG5804A966G-DF

Page 1: ...a Dual Multimode Fibre Link The AMG5804A966G DF is a rackmount data transmit unit designed to transmit and receive 2 data channels 6 audio channels 2 Echelon FTT 10A data channels and 8 bi directional...

Page 2: ...ns 4 Echelon FTT 10A Data Channel Connection 4 Ethernet Connection 5 Front Panel Indicators 6 Power LED 6 Low Speed Data LEDs 6 Audio LEDs 6 Alarm LEDs 7 Echelon FTT 10A Data LEDs 7 Ethernet Data LEDs...

Page 3: ...04A966G DF transmits and receives 2 data channels 2 Echelon FTT 10A data channels 6 bi directional audio signals and 8 bi directional alarm signals to from the AMG5803A966G DF receive unit Ethernet co...

Page 4: ...terfaces RS 232 422 485 Selected by external slide switches D1 D2 RS 232 Switch Position Top RS 422 Switch Position Middle RS 485 Switch Position Bottom Internal 120 termination resistors may be appli...

Page 5: ...its use Page 5 of 12 AMG5804A966G DF Instruction Sheet D17400 00 doc Echelon FTT 10A BANK A Channels 7 and 8 Echelon FTT 10A BANK B None Connector 37 way D Type female connectors shielded Connections...

Page 6: ...transitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted onto the optical fibre Data Present OUT RS485 or RS422 Green logic zero V V pre...

Page 7: ...onto the optical fibre Data Present OUT Green Data channel present but not transmitting R G Data channel receiving Off Data channel not present or no connection OUT corresponds to the data signals bei...

Page 8: ...ion A level above 600mV positive or negative will be detected as a logic 1 or logic 0 respectively It is important therefore to terminate the RS 485 bus or the RS 422 input bus using 120 if a pre bias...

Page 9: ...ently as required The 3 examples shown are RS 232 no termination RS 422 120 or RS 485 120 Alarm Channel Configuration The AMG5804A966G DF provides 8 bi directional contact closure inputs alarm outputs...

Page 10: ...2 6 IN ALARM 2 6 OUT 3 GND GND 4 ALARM 3 7 IN ALARM 3 7 OUT 5 ALARM 4 8 IN ALARM 4 8 OUT Audio Channel Connections The AMG5804A966G DF provides six bi directional audio channels Each audio channel in...

Page 11: ...3 Audio CH2 IN A 22 Audio CH2 OUT A B 4 Audio CH2 IN A 23 Audio CH2 OUT A B 5 Audio CH3 IN A 24 Audio CH3 OUT A B 6 Audio CH3 IN A 25 Audio CH3 OUT A B 7 Audio CH4 IN A 26 Audio CH4 OUT A B 8 Audio C...

Page 12: ...practice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector faces or point them at other peop...