AMG5514A9-DF-MP Instruction Sheet 
D17395-00.doc 
 

 

 

 

 

AMG5514A9-DF-MP      

Instruction Manual  

Revieve Unit with one Bi-directional Data Channel, one Bi-

directional Alarm and one Bi-directional Audio Channel for 

a Singlemode Fibre Link 

 

 

 

 

 

 
The 

AMG5514A9-DF-MP

 is a standalone recieve unit designed to transmit & receive one Bi-

directional alarm, one Bi-directional audio channel and one Bi-directional data signal over two 
Singlemode optical fibres.   
 
The 

AMG5514A9-DF-MP

 is designed to be powered using an 

AMG2001

 standalone power supply. 

 
The 

AMG5514A9-DF-MP

 is designed to operate with an 

AMG5513A9-DF-MP / AMG5513A9R-DF 

receive unit in a point to point configuration. The R suffix in the part no. indicates a rackmount version. 
 
 

 

155mm between mounting slot 

centres (4mm slots) 

 

 

 

122mm 

between 

slot 

centres  

 

 

 

132mm 

overall  

 

 

 

172mm overall  

 

 

 

Summary of Contents for AMG5513A9-DF-MP

Page 1: ...glemode Fibre Link The AMG5514A9 DF MP is a standalone recieve unit designed to transmit receive one Bi directional alarm one Bi directional audio channel and one Bi directional data signal over two S...

Page 2: ...ections 4 Optical Connections Singlemode 4 Power Connection 4 Data and Alarm Channel Connections 4 Audio Connections 4 Front Panel Indicators 6 Power Opto LED 6 Low Speed Data LEDs 6 Alarm LEDs 6 Audi...

Page 3: ...he AMG5514A9 DF MP transmits 1 data 1 Bi directional alarm and 1 audio signal to the AMG5513A9 DF MP receive unit It also receives 1 data 1 Bi directional alarm and 1 audio signal transmitted from the...

Page 4: ...ly Voltage 12 to 15 Volts DC Maximum Power 1 5 Watts Data and Alarm Channel Connections No of Data Channels 1 No of Alarms 1 Connectors Removable 8 pin 2 5mm Screw Terminal Connector Partno Phoenix 18...

Page 5: ...sponsibility is assumed by AMG for its use Page 5 of 12 AMG5514A9 DF MP Instruction Sheet D17395 00 doc Audio Input impedance is selected by removable jumper JP1 or JP2 on Audio Expansion board inside...

Page 6: ...ng transmitted onto the optical fibre Data Present OUT RS485 or RS422 Green logic zero V V present on OUT OUT Red logic one V V present on OUT OUT Off tri state off or no connection on OUT OUT Data Pr...

Page 7: ...a channel as shipped from the factory is set up for RS 485 operation unless otherwise requested The data input for both the RS 485 and the RS 422 modes detects a tri state input condition by monitorin...

Page 8: ...cification Alarm Channel Configuration The AMG5514A9 DF MP provides 1 Bi directional alarm output contact closure input The alarm input is typically connected to a contact closure switch An ALARM IN i...

Page 9: ...input can be configured as a single ended high impedance 10k input with GND reference or alternatively as a balanced 600 input pair The input impedance is selected using jumpers on the audio expansio...

Page 10: ...always advisable to follow good practice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector f...

Page 11: ...make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 11 of 12 AMG5514A9 DF MP Instruction Sheet D17395 00...

Page 12: ...make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 12 of 12 AMG5514A9 DF MP Instruction Sheet D17395 00...

Reviews: