AMG AMG3708BRN-DR-SF Instruction Manual Download Page 1

AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.

Page 1 of 16

AMG3708BRN-DR-SF Instruction
Sheet D18169-01.doc

AMG3708BRN-DR-SF

Instruction Manual

Data Receive Unit with 9 Bi-directional Data Channels for a

Dual Redundant Singlemode Fibre Ring - includes AMG

NMS Network Management Interface

The

AMG3708BRN-DR-SF

is a rackmount data receive unit designed to receive to transmit and

receive 9 bi-directional data channels to/from up to 8

AMG3703B2-DR-SF

or

AMG3703B2R-DR-SF

rackmount equivalent insert units over a dual redundant singlemode optical fibre ring. One data
channel is a multi-drop RS-485 link, the other eight data channels are effectivly point to point RS-232
links.

The

AMG3708BRN-DR-SF

is designed to plug into an AMG2009 or AMG2015 subrack, which in turn

fits into a 19" rack system. It also includes an AMG Management Interface to allow Management of the
system using the AMG SNMP enabled Management software.

The

AMG3708BRN-DR-SF

is designed to operate with up to eight

AMG3703B2-DR-SF

data insert

units. Each receiver will 'drop off' one RS-485 multi-drop channel plus up to eight RS-232 individual
data channels which are being transmitted around the fibre ring.

Summary of Contents for AMG3708BRN-DR-SF

Page 1: ...to from up to 8 AMG3703B2 DR SF or AMG3703B2R DR SF rackmount equivalent insert units over a dual redundant singlemode optical fibre ring One data channel is a multi drop RS 485 link the other eight d...

Page 2: ...ta and Audio Channel Configuration 6 Data Channel A Configuration 6 Data Interface Connections Channel A 6 Bank B Data 7 Data Interface Daughter Board Options 7 Data and Audio Channel Configuration 7...

Page 3: ...s each unit regenerates the optical signal the optical dynamic range between each optically connected node is 17dB Data Channel Configuration At the AMG3703B2 DR SF or rackmount AMG3703B2R DR SF inser...

Page 4: ...ystem single channel data insert units can be combined to make an 8 channel data transmission system as illustrated below If a fibre link is broken operation of the ring continues by making use of the...

Page 5: ...onnection on the AMG2009 AMG2015 subrack Power consumption 15 Watts max Data and Audio Channel Connections Total No of Data Channels 9 channels DATA CHANNEL A Data Channel A 1 channel Data Connector R...

Page 6: ...y monitoring the differential voltage level across the input A differential level below 600mV positive or negative will be detected as a tri state condition A level above 600mV positive or negative wi...

Page 7: ...e Daughter Board 5 X12578 Contact Closure Data Interface Daughter Board 6 X13038 FTT10A Echelon Lonworks Data Interface Daughter Board Data and Audio Channel Configuration The data expansion board slo...

Page 8: ...CH3 OUT A B 6 Audio Data CH3 IN B B 25 Audio Data CH3 OUT B B 7 Audio Data CH4 IN A B 26 Audio Data CH4 OUT A B 8 Audio Data CH4 IN B B 27 Audio Data CH4 OUT B B 9 GND B 28 GND B 10 GND B 29 GND B 11...

Page 9: ...5 or RS422 Green logic zero V V present on IN IN Red logic one V V present on IN IN Off tri state off or no connection on IN IN Data Present TX RS232 Green logic zero V present on input IN Red logic t...

Page 10: ...represents the data signals being transmitted on the optical fibre Data Present CH1 8 RX Green logic zero V V present on OUT OUT Red logic transitions present on OUT OUT Off logic one V V present on...

Page 11: ...each Rx or Tx RS 232 or RS 485 on Management Port Multiple Rx Tx units use RS 485 and effectively parallel all the RS 485 ports together Connect to PC RS 232 Port via RS 485 RS 232 convertor Propriet...

Page 12: ...it is recommended that the RS 485 interface is used with each RS 485 pair connected in parallel In this case an RS 485 to RS 232 USB converter is required in order to connect to a standard PC Comms P...

Page 13: ...ange from this recorded state A change of state would be Addition or loss of video at any insert node Addition or loss of primary optical input at any node Addition or loss of secondary optical input...

Page 14: ...ot snag or get trapped To replace the PCB s into the case slide the PCB s gently into the case aligning the boards with the appropriate slots Ensure that the fibre do not snag or get trapped Safety AM...

Page 15: ...make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 15 of 16 AMG3708BRN DR SF Instruction Sheet D18169 0...

Page 16: ...make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 16 of 16 AMG3708BRN DR SF Instruction Sheet D18169 0...