Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-55
Figure 3-52: Voltage Ref Mode channel 3
Entry
Description
INT
Sets the Voltage Reference Mode into internal for selected channels.
Allows user to program the output voltage through front panel and
digital interfaces.
EXT
Sets the Voltage Reference Mode into external for selected channels.
Allows user to program the output voltage only through the analog
programming interface.
INT + EXT
Sets the Voltage Reference Mode into in external for selected
channels. Allows user to program the output voltage through the analog
programming interface, front panel, and digital interfaces.
3.4.6.6
O
UTPUT
O
N
/O
FF
D
ELAY
Output On/Off Delay screen permits to configure Output ON/OFF Delay settings. If
Disable is selected the Output channels would become individual and user is restricted
to configure the output On/Off delay settings from the OUTPUT ON/OFF DELAY Top
Level Menu to turn On/Off the output of channels in a sequence. If Enable is selected,
it allows user to configure the output On/Off delay settings from the OUTPUT ON/OFF
DELAY Top Level Menu to turn On/Off the output of channels in a sequence.
Figure 3-53: Output On-Off Delay enable screen
Entry
Description
Enable
Sets the OUTPUT ON/OFF DELAY top level menu in enabled
condition. Allows user to program the output ON/OFF delay.
Disable
Sets the OUTPUT ON/OFF DELAY top level menu in disabled
condition. Restricts user to program the output ON/OFF delay.