Description
CC/CV/CP
Sets the Regulation Mode as CC/CV/CP for selected channel. Supply
switches between the CC (constant current), CV (constant voltage)
and CP (constant power) modes based on the load conditions, without
making the output to zero.
CC Mode
Sets the Regulation Mode as CC for selected channel. Supply
regulates the output current at the set value. If the regulation of
selected channel output current is not met due to change in load, it
programs the respective channel output to zero after a programmable
delay time.
CV Mode
Sets the selected channel Regulation Mode as CV. Supply regulates
the output current at the set value. If the regulation of selected channel
output current is not met due to change in load, it programs the
respective channel output to zero after a programmable delay time.
CP Mode
Sets the selected channel Regulation Mode as CP. while in this mode,
the supply will continually adjust the voltage and current levels of
selected channel to attempt to maintain a constant power to the load.