The following choices are available in the Output Settings screen. Functions that
accept a numeric value require that the value be within the allowed range, otherwise,
an error will be generated, and the value will not be accepted.
Entry
Description
Voltage
Programs the output voltage in Volts for respected channel. The default
value of each channel would be same that of the programmed power
ON settings.
Current
Programs the output current in Amperes for respected channel. The
default value of each channel would be same that of the programmed
power ON settings
.
Power
Programs the output power in watts(W) for respected channel. The
default is module power of each channel.
OVP
Programs the Overvoltage Protection (OVP) threshold for the
respected channel output voltage. Exceeding the OVP threshold will
result in shutdown of the output and the output voltage programmed to
zero. The default value of each channel would be same that of the
programmed power ON settings
.