Power connector
The device’s power connector should have the following pin connections:
I/O Cable
The 25-pole communication cable between the “I/O CONTROL” connector and the
appropriate port on the packaging machine has the following pin connections:
Pins/Colours/
Function
Description
1 - White
2 - Brown
"Start/Stop"
Start/Stop signal from packaging machine / PLC.
Signal must be stable: 10-32VDC (bipolar), consumption: 10mA
max.
5 - Grey
6 - Pink
"Alarm", NO
Alarm relay output. Activated if input gas pressure is lower
than pressure alarm limit.
Relay contacts: Normally Open (NO), max. 48V, max. 1A
Contacts closed during power OFF
N
Not in use
L
AC Power
DC Power
GND
1
3
25
12
24
11
2
3
10
22
9
21
8
20
7
19
6
18
5
17
4
16
3
15
2
14
1