Network LDT - Configuration Manual

ABSOLUTE PROCESS CONTROL

     KNOW WHERE YOU ARE... REGARDLESS

Summary of Contents for 953N Series

Page 1: ...ReadyLink EtherNet IP LDT with RapidRecall Network LDT Configuration Manual ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE REGARDLESS...

Page 2: ...this manual All rights to the contents of this manual are reserved by Ametek Function of this Document These operating instructions are designed to address the technical aspects of commissioning our E...

Page 3: ...Explicit messages are used for configuration data such as position scaling resolution and count direction among other parameters The Network LDT module conforms to the Encoder device profile device t...

Page 4: ...GREEN Rx REVISIONS ZONE REV DESCRIPTION D A RELEASED 5 12 DR DATE APP DATE SCALE DRAWING NO TITLE TOLERANCE ALLOWANCE 0 010 ON 2 PLACE DECIMALS 0 005 ON 3 PLACE DECIMALS 0 0005 ON 4 PLACE DECIMALS 30...

Page 5: ...YLE FULL PD0124500 A D 3 00 76 20 4 24 107 70 22 5 59 2 PER MTG FOOT 60 15 24 30 7 62 36 9 02 30 7 62 1 37 34 80 1 97 50 04 2 68 68 07 R 87 22 01 360 ROTATION 99 25 02 MOUNTING BRACKETS SLIDE IN THE G...

Page 6: ...ed to the coupling nut the LDT s shield should NOT be tied to the earth ground at the power supply See figure 4 2 Grounding Connections In order for the Network LDT to operate properly the LDT s exter...

Page 7: ...be Customer Power Supply Power Supply cable shield IS connected to connector coupling nut Network Cable lengths Per ODVA specifications it is recommended that the maximum total cable run length be 100...

Page 8: ...hernet IP LDT There are four ways to program the IP address in the Network LDT Through our IPconfig Network utility program Switches must be set to 255 Through BootP DHCP server Switches must be set t...

Page 9: ...e made to the Network LDT for both communications and power and the switches in the Rapid Recall module must be set to 255 Step 2 Access Network LDT 1 Make sure the configuration DIP switches are set...

Page 10: ...te A module configuration screen will open to configure or modify the EtherNet IP address In the Request History Pane you will see the time a message came from an EtherNet module data type and MAC Add...

Page 11: ...nd MAC address At this point the IP address is only temporary since the DHCP is still enabled Step 4 Click on the IP address in the Relations List Pane to highlight that row then click the Disable BOO...

Page 12: ...call Configuration Module and set the DIP switches to 255 Step 4 Reapply power The network will now assign the next available IP address From here you should be able to follow the IPconfig or BootP in...

Page 13: ...le Support 1 Position R No 2 Position Warning and Alarm Flags R No 3 Position and Velocity R No 100 Position Velocity and Status R No 101 Position Velocity and Extended Status R No 110 Configuration R...

Page 14: ...locity and Status Assembly Instance 101 Same as Instance 100 except 12 bytes in length Position Velocity data will look like a decimal value in the correct order Buffer Offset Length Data Mapped Attri...

Page 15: ...e an array consisting of all supported attribute numbers in numerical order Position Value Signed Attribute 10 The current position value read by the module This value will be scaled based on the Posi...

Page 16: ...Value inch sec 1000 0 001 inch sec inch sec 100 0 01 inch sec centimeter sec 100 0 01centimeter sec centimeter sec 10 0 1centimeter sec Minimum Velocity Setpoint Attribute 27 If the Velocity Value is...

Page 17: ...ure expansion At the current time the only version available is Asynchronous This is an enumerated value with the following allowable values Value Sync Mode 0 Async 1 Sync 4 3 3 Services Service Code...

Page 18: ...uploading the configuration data to the RapidRecall Configuration Module is that if anything was to ever go wrong with the LDT the module could be removed from the original unit and installed on the n...

Page 19: ...t Output Type Sync Mode The page will also provide the ability to set the Preset Value to calibrate the position to the current location The Load button will load the pending values into the working p...

Page 20: ...ndow In the Options window select Register an EDS File then click Next 4 Registration Register a single file The Registration windows opens click Browse and select EDS file downloaded from the www ame...

Page 21: ...Name field and select the IP address radio button and enter the IP address that is assigned to the sensor Click on the Change button in the Module Definition field 4 Module Definition The following D...

Page 22: ...times out connections are re established or if the module is reset Red On The module has detected that its IP address is already in use Green Red Flashing The module is performing a power on self test...

Page 23: ...ve Restore Reset Communication Settings 888 Complete Restore to Factory Settings i e initialized to out of box condition IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Gateway Address 192 168 1 254...

Page 24: ...d Buna N or V Fluoroelastomer Depending on where these units will be mounted and what chemicals they may be exposed to will help determine which option is best for your application 953N 0120 IP R Stro...

Page 25: ...Communications Cable M12 D Right Angle to M12 D Right Angle 1Meter 949040L1M Communications Cable M12 D Right Angle to M12 D Right Angle 5 Meter 949040L5M Communications Cable M12 D Straight to RJ45...

Page 26: ...VDC 10 VDC 0 5 VDC 5 VDC 4 20mA Digital output Start Stop Control Pulse and Variable Pulse PWM SSI Synchronous Serial Interface 24 25 or 26 Bit Binary or Gray Code Synchronous or Asynchronous Mode Rem...