Page 64
Signal Processor
User Guide
LMG AE
The following application example is more complex in that it utilises two
quench exit thermometers as well as a die exit thermometer.
Fig. 46 - Typical ‘Die Exit and Dual-Quench Exit’ Application
234051
LMG
AE
Processor
AET
Speed
Sensor
Extrusion
Press
Quenching
Section 1
Quenching
Section 2
AQT (1)
AQT (2)
In the above application there is no billet snap shot function instead there are
two quenching zones.
The basic LMG
AE
configuration for the above would be as follows:
Set CHA to have an AET thermometer selected.
Set CHB to have an AQT thermometer selected.
Set CHC to have an AQT thermometer selected.
Set CHD to have a speed sensor selected.
There are three possible quench rate calculations i.e.
1
AET => AQT (1)
2
AET => AQT (2)
3
AQT (1) => AQT (2)
The user must choose the two of interest which can then be
calculated independently.