![Ametek Land 4500 MKIII User Manual Download Page 38](http://html1.mh-extra.com/html/ametek-land/4500-mkiii/4500-mkiii_user-manual_2931437038.webp)
Opacity and Dust Monitor
User Guide
Model 4500 MkIII
A - 32
A6 AFU-APS-I/O: Auxiliary Power Supply (APS)
A6.1 Description
The Auxiliary Power Supply (APS) side of the AFU-APS-I/O contains a 24 V
dc Power Unit for the AFU and/or Transceiver. It requires an ac mains input
in the range 90 to 132 or 187 to 260 V ac, 50 to 60 Hz. The supply voltage
range is selected automatically.
It also contains circuit breakers and terminals for supplying ac power to two
blowers.
For specifications, see Section D.
The APS can be supplied as an integrated unit with an AFU, or as a standalone
unit.
The standalone units can supply power to the AFU (and thus the 4500 MkIII)
or to the 4500 MkIII directly.
CAUTION
Only Land-supplied blowers may be connected safely to the APS.
The connection of any other equipment to the shutter/blower
terminals may be hazardous.
Approved blowers are listed in the table below:
Part Nº
Description
099.471 Plate-Mounted Blower (230 V, 50 Hz)
099.472 Plate-Mounted Blower (220 V, 60 Hz)
099.473 Plate-Mounted Blower (110 V, 60 Hz)
803550
Blower Small, USA (220 V, 60 Hz)
803551
Blower Small, USA (110 V, 60 Hz)
806441
LC Economy Blower (110 V, 60 Hz)
806440
LC Economy Blower (230 V, 50 Hz)
CAUTION
Incorrect supply voltage/frequency can cause the motor to burn
out, compromise performance or cause an explosion.
The connection of a blower restricts the allowable voltage range of
the APS to that of the shutter/blower.
The blower supply voltage/frequency are detailed on the rating
plate of the supplied motor. Check carefully.
Do not exceed the rated supply values. External wiring must be
rated to >70°C / 158°F if the ambient temperature can rise above
50°C / 122°F.
Summary of Contents for 4500 MKIII
Page 4: ...Opacity and Dust Monitor User Guide Model 4500 MkIII Preface Blank...
Page 6: ...INTRODUCTION A...
Page 29: ...A 23 Model 4500 MkIII Opacity and Dust Monitor User Guide A4 3 Mounting the AFU APS I O...
Page 41: ...GETTING STARTED B...
Page 42: ...Opacity and Dust Monitor User Guide Model 4500 MkIII Preface Blank...
Page 76: ...THEORY OF OPERATION AND APPLICATION C...
Page 86: ...SYSTEM SPECIFICATION D...
Page 91: ...MAINTENANCE E...
Page 108: ...CHANGING THE INSTALLATION PATHLENGTH F...
Page 113: ...INSTRUMENT RECORD SHEETS G...
Page 114: ...Blank...
Page 117: ...OPTIONAL I O MODULES FOR AFU H...
Page 118: ...Blank...
Page 124: ...LONG PATHLENGTH OPTION App 1...
Page 126: ...Opacity and Dust Monitor User Guide Model 4500 MkIII App 1 2...