background image

OPERATION 

Do not use a grate or elevate the fire

. Build the wood. 

When the stove is used for the first time, solvents in 
the paint will smoke off as the stove “cures.” 

WOOD

This heater is designed to burn natural wood only.  
Higher efficiency and lower emissions generally 
result when burning air-dried seasoned hardwood, 
as compared to softwood or to green or freshly-cut 
hardwood. 

Use only dry, seasoned wood. Green wood, besides 
burning at only 60 percent of the fuel value of dry 
wood, deposits creosote on the inside of the stove and 
along the chimney.  This can cause extreme danger of 
chimney fire.  

To be called “seasoned,” wood must be 

dried for a year

. Regardless of whether the wood is 

green or seasoned, it should be stored in a ventilated, 
sheltered area to allow proper drying during the 
year. Wood should be stored beyond recommended 
clearances from combustibles. 

DO NOT BURN: 
Treated Wood, Garbage, Solvents, Trash, Cardboard, 
Colored Paper or Coal. 

FIRST FIRE

• Fit the baffle as shown in the section “Fitting the 
Baffle” 

• Allow the stove to cure before burning for long 
periods of time at high temperatures. 

•  When the fireplace is lit for the first time, the fireplace 
will produce smoke and smell 
like resin for a few hours. Open the windows to 
ventilate.

• Flat spots on the painted surface are normal. 

•   Shiny spots on the painted surface (before burning) 
are normal. 

•   Call Technical Support at (800) - 444 - 6742 if you 
have any questions.

BUILDING A FIRE

1. 

  Open the air inlet control fully. 

2. 

  Place a small amount of crumpled paper in the 

stove. 

3.

   Cover the paper with a generous amount of 

kindling in a “teepee” shape, and a few small pieces 
of wood. 

4.

   Ignite this fuel and close the door most of the way 

(leave it open slightly). 

5.

  Add larger pieces of wood as the fire progresses, 

being careful not to overload.  

Do not fill the firebox 

beyond the firebrick area, as this may result in 
over-firing

. A coal bed of (ideally) 1” to 2” should be 

established to achieve optimum performance. 

6. 

 This unit is designed to function most effectively 

when air is allowed to circulate to all areas of the 
firebox.  A good way of achieving this is to rake a small 
(1” to 2” wide) “trough” in the center of the coal bed, 
from front to back, prior to loading the fuel.
 

7. 

  Once fuel has been loaded, close the door and 

fully open the air inlet control, until the fire is well 
established (approximately 20 minutes), being careful 
not to over-fire. 

8. 

Readjust the air inlet control to the desired burn 

rate.  If excessive smoke fills the firebox, open the 
air inlet control slightly, until flames resume and the 
wood is sufficiently ignited. Basically, Closed = “Low;” 
½ Way Open = “Medium;” and Fully Open = “High.”   

9.

 

When refueling, adjust the air control to 

the fully open position

. When the fire brightens, 

open the door 

VERY

 slowly and carefully.  This will 

prevent gases from igniting and causing smoke and 
flame spillage. 

10.

  At this point you may add fuel, being careful not 

to overload. 

The use of flammable liquids, too much wood or 
burning trash in the stove may result in an “over¬fired” 
unit. If the chimney connector pipe or stove turns red 
or white, the stove has been over-fired. In the event 
this happens, close the air control immediately! This 
condition can ignite creosote in the chimney and 
cause a house or chimney fire. This type fire can cause 
structural damage to the chimney system; do not 
use the stove again until the entire system has been 
checked thoroughly and any damaged parts repaired 
or replaced. A chimney sweep can normally perform 
this inspection. 

NEVER USE GASOLINE, GASOLINE-TYPE LANTERN 
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR 

SIMILAR LIQUIDS TO 
START OR ‘FRESHEN 
UP’ A FIRE IN THIS 
HEATER.  KEEP ALL 
SUCH LIQUIDS WELL 
AWAY FROM THE 
HEATER WHILE IT IS 
IN USE.

GLASS CARE 

REPLACE GLASS ONLY WITH CERAMIC GLASS 

USE HIGH-TEMPERATURE ROBAX® PYROCERAM or 

NEOCERAM® OF THE PROPER SIZE AND THICKNESS.

R450 glass thickness    : 4 mm/0.16 in 
R450 glass size 

        : 225 mm x 250 mm

 

 

        : 8,86 in x 9.84 in

The following use and safety tips should be 
observed: 

1. 

 Inspect the glass regularly for cracks or breaks.  

Surface scratches are acceptable and normal, but 
if you detect a crack or a break, extinguish the fire 
immediately, and contact your dealer or Technical 
Support at 800-444-6742 for replacement.

2.  

 Do not slam the door or otherwise impact the 

glass. When closing doors, make sure that logs or 
other objects do not protrude and impact the glass. 

3.

  Do not clean the glass with materials which may 

scratch (or otherwise damage) the glass. Scratches on 
the glass can develop into cracks or breaks. 

4. 

 Never attempt to clean the glass while the unit 

is hot.  If the deposit is not very heavy, normal glass 
cleaners are adequate with a plain, non-abrasive 
scouring pad. Heavier deposits may be removed with 
the use of an oven cleaner. 

12

13

Summary of Contents for R 450

Page 1: ...h July 1990 Particulate emission standards Tested to UL 1482 2000 ULC S627 2000 OWNER S MANUAL MODEL NUMBER AMESTI R 450 Thank you for purchasing this product from a fine line of heating equipment fro...

Page 2: ...ite at www amesti cl for helpful information frequently asked questions parts accessory orders and more Technical Support 800 444 6742 OPERATION WHY THE CORRECT FLUE SIZE IS IMPORTANT 6 Draft is the f...

Page 3: ...amage caused by the malfunction of a stove due to improper installation Do not use makeshift methods or material which may compromise the installation The manufacturer will not be responsible for an a...

Page 4: ...or a single wall sheet steel chimney connector of minimum 24 gauge thickness with a minimum 2 in air space between the outer wall of chimney section and combustibles Minimum length of chimney section...

Page 5: ...k up you will need wall protection at least twelve inches 12 above the wall thimble i R value is given no conversion is needed ii k factor is given with a required thickness T in inches R 1 k xT iii C...

Page 6: ...tallation rigid 10 Maintain the required diameter flue for the entire installation 11 If you are connecting the stove to an old masonry flue besuretohaveitinspectedforcracksandgeneral condition Relini...

Page 7: ...nlet control until the fire is well established approximately 20 minutes being careful not to over fire 8 Readjust the air inlet control to the desired burn rate If excessive smoke fills the firebox o...

Page 8: ...ufacturer includes a steel handle with each fireplace This handle must be used to open and close the door and to move the air control lever The handle must be stored away from the fireplace to prevent...

Page 9: ...60 of the fuel value of dry seasoned wood will deposit creosote on the inside of the stove and along to inside of the chimney 4 What does dry seasoned wood mean and what is considered to be hardwood...

Page 10: ...his fireplace referring to the materials and manufacturing will be free of defects at the time of purchase The manufacturer extends the following warranties Five Year Period Steel and welded joints in...

Page 11: ...____ Dealer store Other ____________________________________________________ Where did you receive information about our product Please check one ___ Rec d info via phone ___ Dealer Name of dealer ___...

Page 12: ...16 Visitez notre site web www amesti cl pour des informations utiles questions fr quentes commande de pi ces accessoires et plus Assistance Technique 800 444 6742 FONCTIONNEMENT POURQUOI UNE TAILLECO...

Page 13: ...nsabledesaccidents dus au raccordement de l unit un syst me de chemin e d fectueux APPLICATIONS D INSTALLATION Illustration 1 Si vous rencontrez de tels probl mes consultez un expert local en chemin e...

Page 14: ...vantde passage pour le connecteur mural de la chemin e en t le d acier de calibre 24 minimum d paisseur avec un espace d air de deux pouces 2 minimum entre la paroi ext rieure de la section de la chem...

Page 15: ...murale d au moins douze pouces 12 au dessus de la cartouche murale i la valeur R est donn e pas de conversion requise ii le facteur k est donn avec une paisseur T requise en pouces R 1 k xT iii le fa...

Page 16: ...c un rev tement en acier inoxydable peut tre requis 12 Il est recommand que pas plus de deux coudes de 90 soient utilis s dans l installation du conduit Plus de deux coudes de 90 pourraient diminuer l...

Page 17: ...u soit bien tabli environ 20 minutes faites attention la surchauffe 8 R ajustez l arriv e d air jusqu la vitesse de combustion d sir e Si un exc s de fum e remplit le foyer ouvrez l g rement l arriv e...

Page 18: ...aporteetlaissezlecimentprendrependant trois quatre heures avant de rallumer un feu Assemblage de la Porte AMESTI R 450 POIGNEE FROIDE ET CONTROLE D ARRIVEE D AIR Le fabricant inclut une poign e d acie...

Page 19: ...utiliser comme bois de chauffage Du bois sec et dur doit tre utilis Evitez les bois verts ou non s ch s Le bois vert en plus de ne bruler qu 60 de la valeur nerg tique des bois secs d posera de la cr...

Page 20: ...PROPRIETAIRE ORIGINAL AMESTI garantit que toutes les pi ces de ce po le se r f rant des mat riaux et de fabrication seront exemptes de d fauts au moment de l achat Le fabricant tend les garanties suiv...

Page 21: ...reporter l autocollant sur l int rieur des pieds du foyer pour compl ter cette partie Num ro de mod le_________________________ Date d achat _____________________________ Prix d achat ________________...

Page 22: ......

Reviews: