background image

SECTION 1 - PREPARATION FOR INSTALLATION

Tools Needed

Parts of this Light Fixture
-  12” or 16” or 22” Light Fixture.
-  Linking Cord
-  Power Cord with On/Off switch
-  Mounting Hardware

SECTION 2 - INSTALLATION 

Placement of Fixture and Touchless Dimming Controller
Determine location for connecting to nearest 120V receptacle. (Note: before mounting 
to cabinet be sure fi xture is within 5’ of an electrical outlet, considering path cord will 
take to be neatly and securely mounted to cabinet and wall.) 

If you are not sure about 

this installation consult a local licensed electrician or electrical contractor before 

proceeding.

Step 1: Locate Mounting Holes: Place brackets on mounting surface and with a pencil 

mark the spot where the screws will be located. See Figure 2. Do the same for a multiple 
fi xture installation.

Step 2: Drill Holes and Attach Brackets: For mounting into wood cabinets drill 1/16” pilot 

holes, 1/2” deep. 

Caution: Check your cabinet thickness fi rst. Be careful not to drill 

through cabinet. For mounting into drywall, drill 3/16” holes for the plastic wall anchors 

(not included). Insert the plastic wall anchors into the proper holes and tap them into 
place so they are fl ush with the surface of your drywall. 

Step 3: Attach Fixtures: Attach fi xture to mounting brackets by snapping into place. 

Connect 5’ Power Cord to the fi xture. Plug in Power Cord to a 15A circuit grounded 
outlet. Light may be turned on or off using the toggle switch built into the cord. 

Warning: 

Do not conceal power supply cord inside a wall, ceiling, soffi t, kitchen cabinet, or similar 

permanent structure. Do not run the power supply cord through holes in walls, ceilings or 

fl oors.

Use UL listed cable staples (not included) to route Power Cord to bottom of cabinet and 
wall for a clean installation.

Interconnecting Multiple Fixtures
WARNING: In multiple fi xture installations do not electrify fi xture group until all electrical 

connections have been made and fi xtures have been securely mounted. For the CTRO 

DIY Series Undercabinet Light the maximum wattage of linked fi xtures is 100W. The table 

below shows wattage and maximum number of bars of all one kind. If various length 

bars are used be sure not to exceed the maximum wattage allowed. DO NOT EXCEED 

THIS QUANTITY. 

Model #

Bar Length

Watts

Max No. Linked

CTRO-L12W

12”

3

16

CTRO-L16W

16”

4

12

CTRO-L22W

22”

7

7

CTRO Series fi xtures may be interconnected using the Linking Cord supplied with this kit or 
by directly connecting each light bar. Linking cords and light bars can only be attached 
in one way as each connector has a different end. See Figure 3.

Follow Fixture Installation instructions above. When using the Linking Cord, there should 
be some slack in the cord so that the electrical connectors are not stressed in any 
way. Use cord clips (not included) to keep cord safely attached to mounting surface. 
WARNING: Do not use Linking Cord as a means to turn fi xtures on and off. Do not link 
other manufacturer’s or other Westek brand fi xtures to this fi xture.

DIY Series LED Undercabinet Lighting

Models: CTRO-L12W, CTRO-L16W and CTRO-L22W

IMPORTANT SAFETY INSTRUCTIONS

For use with 120V, 60Hz electrical power supply only.
WARNING: TO PREVENT OVERHEATING AND ELECTRICAL SHOCK DO NOT INSTALL IN SMALL ENCLOSED SPACES. TO 
PREVENT ELECTRICAL SHOCK DO NOT INSTALL IN WET LOCATIONS.

SAVE THESE INSTRUCTIONS

1.  Read and understand all of these instructions before installing fi xture.
2.  Keep these instructions in a safe place for future reference.
3.  Do not mount over sink or stove. 
4. 

WARNING: These products may represent a possible shock or fi re hazard if improperly installed or attached in any way. 

Products should be installed in accordance with these instructions, current electrical codes and/or the current National 
Electric Code (NEC).

FEATURES

Plug-in design for easy installation
Quick and easy linking system
On/Off switch
Slim Line Bar

INCLUDES

CTRO Series Plug-in Light Fixture (12” or 16” or 22”)
 (1) Power Cord, (1) Linking Cord, Mounting Hardware.

CET 

INSTRUCTIONS FOR INSTALLATION OF 

PLUG-IN LIGHTING FIXTURE

Step 1
Locate Holes

Step 2
Drill Pilot Holes
Attach brackets

Step 3
Attach fixture(s)

Reviews: