![AmeriWater 000-HS120 Operation & Maintenance Manual Download Page 55](http://html1.mh-extra.com/html/ameriwater/000-hs120/000-hs120_operation-and-maintenance-manual_3043934055.webp)
53
098-0007 Rev B
11
ALARMS
11.1
Fault Conditions Display
Alarm
ID
Fault Condition
Fault Description
What to Check
000
Level Sensor
Error
Float switches were detected to
be in the same position (both
closed)
Verify that float switches move
freely
Verify that all connections are
tight
Verify that the low level float
opens on rise and the high
level float closes on rise
001
Disinfection
Abort
User aborted a disinfection cycle
during the Preheat mode or
Dispensing mode. Alarm will be
logged in the alarm history but
will not be displayed on the
screen following a disinfection
*Alarm does not require a reset
by the user prior to starting
another disinfection cycle
002
Over
Temperature
Occurs when the tank
thermocouple detects a
temperature greater than the
Maximum Temperature
setting for at least 30 seconds
Verify that the current tank
temperature is accurate using
a separate thermocouple
Verify that the Maximum
Temperature setting is at
the default value of 197 F
Verify that heating element is
not operating when system is
in standby. Green LED light on
SSR1 will be illuminated when
PLC output for heating
element is active
Verify the Disinfection
Tempe Heater
Shutoff does not exceed the
Maximum Temperature
Verify that both wires for the
thermocouple (PLC input 7 &
8) are inserted securely and
are not touching
Summary of Contents for 000-HS120
Page 2: ......
Page 24: ...22 098 0007 Rev B Right Side...
Page 25: ...23 098 0007 Rev B Left Side Top with top panel and controller removed...
Page 27: ...25 098 0007 Rev B 6 3 Flow Schematic 6 3 1 Standby Mode...
Page 28: ...26 098 0007 Rev B 6 3 2 Preheat Mode...
Page 29: ...27 098 0007 Rev B 6 3 3 Dispensing Mode...
Page 30: ...28 098 0007 Rev B 6 3 4 Drain Mode...
Page 68: ...66 098 0007 Rev B 13 SPARE PART LISTING 13 1 Exploded View...
Page 69: ...67 098 0007 Rev B...
Page 70: ...68 098 0007 Rev B...
Page 71: ...69 098 0007 Rev B...
Page 72: ...70 098 0007 Rev B...
Page 73: ...71 098 0007 Rev B...
Page 74: ...72 098 0007 Rev B...