41
098-0007 Rev B
7.6
Settings Descriptions and Defaults
Setting
Description
Default
Setting
Range
Disinfection
Temperature
This temperature will determine the
temperature at which the Preheat cycle
will end prior to dispensing mode.
Temperatures below 176°F should only be
used for troubleshooting the device.
188°F
50.0-195.0°F
Heat Loss
The heat loss setting sets the temperature
below the disinfection set-point at which
the heating element turns back on.
1°F
0.5-10.0°F
Heater Shutoff
The Heater Shutoff temperature sets the
point at which the heating element is
turned off during the preheat cycle. This
value is added to the disinfection
temperature to prevent the tank
temperature from rising to an unsafe level.
1.5°F
0.5-10.0°F
Maximum Temperature
This temperature sets the maximum
allowable temperature for the device. If
this temperature is exceeded for 30
seconds, the device will activate an “Over
Temperature Alarm”.
197 °F
50.0-203.0°F
Flow Meter Pulses
This setting sets the expected pulses/L of
water passing through the return flow
meter. Setting the value to 0 will disable
the Water loss alarm for the device.
22000
0-99999
7.7
Controller Detail View
Summary of Contents for 000-HS120
Page 2: ......
Page 24: ...22 098 0007 Rev B Right Side...
Page 25: ...23 098 0007 Rev B Left Side Top with top panel and controller removed...
Page 27: ...25 098 0007 Rev B 6 3 Flow Schematic 6 3 1 Standby Mode...
Page 28: ...26 098 0007 Rev B 6 3 2 Preheat Mode...
Page 29: ...27 098 0007 Rev B 6 3 3 Dispensing Mode...
Page 30: ...28 098 0007 Rev B 6 3 4 Drain Mode...
Page 68: ...66 098 0007 Rev B 13 SPARE PART LISTING 13 1 Exploded View...
Page 69: ...67 098 0007 Rev B...
Page 70: ...68 098 0007 Rev B...
Page 71: ...69 098 0007 Rev B...
Page 72: ...70 098 0007 Rev B...
Page 73: ...71 098 0007 Rev B...
Page 74: ...72 098 0007 Rev B...