Confirm EverAlert Integrator Installation

a.  Click on Displays in the menu bar below the DISPLAY LIST.

b. The list of Integrator(s) assigned to the site will display under Integrator menu bar. A green 

status icon next to the Integrator title indicates the Integrator is communicating with the inCloud 

Management Portal. A red status indicates a lack of communication between the Integrator and the 

inCloud Management Portal. This means the Integrator may not be installed correctly or there is a 

network ssue. Reference the Installation Manual for troubleshooting. 

c.  The icons under INPUT 1 and INPUT 2 should be green unless an Alarm is triggered. The icon for 

the triggered input will be red until the Alarm is cleared.  

EverAlert Integrator Status Indication

The status LED on the Integrator indicates the 

connection status and verifies the activation status of the 

INPUT switches.

• RED: Power on, no connection
• ORANGE: IP received
• GREEN: Integrator connected to Portal
• FLASHING GREEN (1 sec interval): INPUT 1 ON
• FLASHING GREEN (3 sec interval): INPUT 2 ON
• FLASHING GREEN (5 sec interval): INPUT 1 ON 

and INPUT 2 ON 

Pre-Installation

1. Determine a mounting location that is near intended monitoring equipment.
2. An Ethernet connection with internet access is required to communicate with the EverAlert 

Management Portal.
• Ethernet 10/100 Base-T
• DHCP enabled network is required

3. 

CAUTION:

 If the Integrator will be connected to Life Safety equipment such as a fire alarm panel, it is 

recommended that these connections be made by the licensed installer of the system.

Unpack the box

Remove the components from the box. Save the packing materials in case you need them later.

Check the contents

Your package contains:

•  Quick Start Guide
•  EverAlert Integrator
•  Power Supply AC-9VDC Wall Plug
•  4 ea. Rubber Feet

9

10

EverAlert

®

 Integrator Start Installation Guide

Please read this first!

If this is your first installation or you have questions at any time during this process, please call 
American Time toll free at 

800-328-8996

.

phone:

 

800-328-8996

 

online:

 

american-time.com      

fax:

 

800-789-1882

mail:

 

140 3rd St. So.; PO Box 707, Dassel, MN 55325-0707

1

2

3

Integrator Output Function

The Integrator Output can activate secondary low-powered devices, such as a 

strobe or alarm (or a larger secondary relay for devices requiring more power), 

when one of the Inputs or a specified Alarm/Weather Alert is activated. The Output 

relay is capable of supporting voltage up to 60VDC or 125VAC, with a maximum 

switched current and carrying current of 1A.  

DO NOT EXCEED THIS VOLTAGE 

AND CURRENT. 

 If greater voltage/current is required for the connected device, the 

Output relay can be used to command a larger relay. 
The wiring shown in Step 5 will keep the secondary device inactive until the 

associated Input is activated.  Switching the wiring from the Normally Closed 

(1) contact to the Normally Open (3) contact will reverse the Output function, 

meaning the secondary device will be active until the associated Input and/or 

Alarm is activated.

11

1. Normally Closed
2. Common
3. Normally Open