background image

19

© American Time

DSY261RSAE Owner's Manual

A

pp
e

nd
ix

M

ai

n

te

n

a

n

ce

Co

de

 B

lue

O

p

e

rat

io

n

In

st

a

llat

io

n

D

e

scr

ip

tio

n

Appendix

Appendix 5
Operator's Flowchart

To Set Time

UP/CLOCK/DOWN switch in 

CLOCK

 position

SET/RUN switch in 

SET

 position

Clock display 24Hr or 12Hr
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing hours 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing minutes 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing seconds 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Display shows 

DONE

Place SET/RUN switch in 

RUN

 

position

To Use as a Clock

Place SET/RUN switch in 

RUN

 

position
UP/CLOCK/DOWN switch in 

CLOCK

 position

Code Blue Operation

SET/RUN switch 

MUST

 be in 

RUN position
To stop and hold code blue time 

for viewing, press 

START/STOP

To Reset Clock/Timer to 

Normal Operation

Place SET/RUN switch 

momentarily in 

SET

 position and 

return switch to 

RUN

 position

To Set UP Counter Preset

UP/CLOCK/DOWN switch in 

UP

 

position
SET/RUN switch in 

SET

 position

Clock displays flashing hours 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing minutes 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing seconds 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Display shows 

DONE

Place SET/RUN switch in 

RUN

 

position

To Use UP Counter

UP/CLOCK/DOWN switch in 

UP

 

position
Place SET/RUN switch in 

RUN

 

position
Place 

RESET

 to display 00:00:00

Place 

START/STOP

 to Begin

Place 

START/STOP

 to Hold

Place 

START/STOP

 to begin 

again
Alarm will sound when preset 

time is reached
Press 

RESET

 to reset counter

To Set DOWN Counter Prese

t

UP/CLOCK/DOWN switch in 

DOWN

 position

SET/RUN switch in 

SET

 position

Clock displays flashing hours 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing minutes 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Clock displays flashing seconds 

digits
Push 

INCREMENT

 to change

Push 

ENTER

Display shows 

DONE

Place SET/RUN switch in 

RUN

 

position

To Use DOWN Counter

UP/CLOCK/DOWN switch in 

DOWN

 position

Place SET/RUN switch in 

RUN

 

position
Place 

RESET

 to display preset 

time
Place 

START/STOP

 to Begin

Place 

START/STOP

 to Hold

Place 

START/STOP

 to begin 

again
Alarm will sound  00:00:00 is 

reached
Press 

RESET

 to reset counter

START/STOP          RESET

INCREMENT          ENTER

RUN

SET

UP

DOWN

CLOCK

12 3/8

5 3/8” 

3.0”

Digital Clock/Timer

Summary of Contents for DSY261RSAE

Page 1: ...Installation and Operation Manual Part H004423 Rev 5 October 2011 DSY261RSAE Digital Clock Elapsed Time Indicator with Code Blue...

Page 2: ...ade with energized parts Electrostatic Sensitive Devices CAUTION This equipment contains electronic devices that are sensitive to static electric charges To guarantee protection for the circuitry of t...

Page 3: ...Setting Time 10 Setting the Up Counter Preset Time 10 Up Counter Elapsed Time Operation 11 Setting the Down Counter Preset Time 11 Down Counter Elapsed Time Operation 11 Free Running Clock Operation 1...

Page 4: ...nformation regarding the Manufacturer s warranty contact the Original Purchaser OWNER S MANUAL The owner s manual does not purport to cover all the details or variations in the equipment described nor...

Page 5: ...with 22 AWG stranded wire with minimum 1 32 thick insulation Clock Circuits 3 0mA max 24vac 120vac Code Blue Circuits 3 0mA max 12vac vdc 30vac vdc ENVIRONMENTAL Ambient Operating Range 10 C to 49 C...

Page 6: ...Control Station the DSY261RSAE can also be used as an up or down counting elapsed timer The elapsed timers can be started stopped resumed and reset Both timer modes have a programmable preset value Wh...

Page 7: ...rmit Clock Timer to operate Up Clock Down Switch Up Position This position is used to choose up counting elapsed timer mode Clock Position This position is used to choose clock mode Down Position This...

Page 8: ...ite to negative common black to positive hot and green to ground w Pull the eight wires from the control station through the second bushing of the back plate assembly The 120vac wires and control stat...

Page 9: ...ower is present on any wire before installation u Pull interconnecting field wires into the double gang box v Connect field wiring interconnecting the ATSTCS Control Station with the Digital Clock Tim...

Page 10: ...lashing Press the INCREMENT switch until the until the desired minutes are shown and then press ENTER Press the INCREMENT switch again to set the desired seconds and then press ENTER The display will...

Page 11: ...osition v Set the SET RUN switch to the SET position The hours digits will be flashing w Using the INCREMENT switch set the desired hours for the preset time then press ENTER The minutes digits will n...

Page 12: ...s system since the 12 hour corrections cannot distinguish AM and PM Setting the Secondary Clock Mode Switch A small rotary switch on the Digital Clock Timer circuit board is used to select the seconda...

Page 13: ...viewing by pressing the START STOP button on the ATSTCS switch panel The Code Blue timer cannot be restarted from the switch panel To reset the clock back to normal operation the RUN SET switch must...

Page 14: ...terminals initiates a Code Blue If the Code Blue contact opens and closes again before the Digital Clock Timer is reset back to normal operation the Code Blue timer will start over from 00 00 00 If a...

Page 15: ...omenon is called memory effect The Ni Cad battery s memory can be erased by deeply discharging the battery and recharging it It is recommended that the operator remove 120vac power from the Digital Cl...

Page 16: ...y Clock Operation For use with 3 Wire Clocks Appendix 1 START STOP RESET INCREMENT ENTER RUN SET UP DOWN CLOCK K1 Common Clock Timer 120v Run Voltage 120vac 35mA Correct Digital Clock Timer Clock Powe...

Page 17: ...Clocks Appendix 2 START STOP RESET INCREMENT ENTER RUN SET UP DOWN CLOCK K1 Correct Common Clock Timer 120v Run Voltage 120vac 35mA Correct Digital Clock Timer From Previous Clock or Master Clock Run...

Page 18: ...cannot be changed and the alarm will not sound Appendix 4 Using the Digital Clock Timer as a Count Down Elapsed Timer Only For applications where the user does not want to use the clock and up count f...

Page 19: ...REMENT to change Push ENTER Clock displays flashing minutes digits Push INCREMENT to change Push ENTER Clock displays flashing seconds digits Push INCREMENT to change Push ENTER Display shows DONE Pla...

Reviews: