background image

2320

749mm

(29-1/2)

2325

803mm

(31-5/8)

381mm

(15)

C/L

495mm

(19-1/2)

INSTALLATION INSTRUCTIONS

YORKVILLE 1.6 GPF TWO-PIECE
PRESSURE-ASSISTED TOILETS

 - Model 2320 Elongated

 - Model 2325 Elongated

        Thank you  for selecting American Standard - the benchmark of fine quality for over 100 years.  To ensure this
 product is installed properly, please read these instructions carefully before you begin. (Certain installations may  

    require professional help.) Also be sure your installation conforms to local codes.

  
   

RECOMMENDED TOOLS AND MATERIALS

Putty Knife  Regular Screwdriver 

Adjustable Wrench 

Carpenters Level 

Tape Measure       Hacksaw

Neoprene or Graphite Felt Gasket     Closet FLange Set         Flexible Supply Tube 

(2) 5/16" Lag Bolts       Sealant

1

   REMOVE OLD TOILET

a. 

Close toilet supply valve and flush tank completely.  Towel or sponge remaining water from tank and bowl.

b. 

Disconnect and remove supply line.  NOTE:

 If replacing valve, first shut off main water supply!

c. 

Remove old mounting hardware, remove toilet and plug wall waste opening to prevent escaping sewer gases.

d. 

Remove closet bolts from flange and clean away old wax, putty, etc. from base area.

 

NOTE: 

 Mounting surface must be clean and perpendicular to the floor

 before

 new toilet is installed!

INSTALL CLOSET BOLTS

Install closet bolts in flange channel, turn 90°,
and slide into place 6" (152 mm) apart and
parallel to floor. (Use putty to hold bolts in 
place if necessary.) Brace under flooring as
needed and drill two mounting pilot holes as
shown.

S

A

V

E

 

F

O

R

 

F

U

T

U

R

E

 

U

S

E

3

2

DIMENSIONS (Nominal)  

NOTE: 

 Distance from floor to

closet flange centerline (rough-in) must be 4" (102 mm) 
with flange surface flush to 1/16" (16mm) max. beyond 
finished wall.

FLUSH TO

1/16" (16mm)

EXPOSED
CLOSET

FLANGE

CLOSET

BOLTS

730419-100 Rev. D

Saniwares

 CAUTION:  PRODUCT IS FRAGILE.  TO AVOID BREAKAGE AND POSSIBLE INJURY
 HANDLE WITH CARE!

NOTE:  

For proper operation these products require a minimum of 20 psi line pressure

P r o d u c t   n a m e s   l i s t e d   h e r e i n   a r e   t r a d e m a r k s   o f   A m e r i c a n   S t a n d a r d   I n c .
©   A m e r i c a n   S t a n d a r d   I n c .   2 0 0 6

 

!

813mm

(32)

FINISHED WALL

FINISHED
FLOOR

152

 

mm

(6)

 324mm
(12-3/4)

152mm

(6)

C/L OF 1/2" DIA HOLES
152mm (6) CENTERS

*

222mm 

(8-3/4)

102

 

mm

(4)

C/L OF
WASTE
OUTLET

FLEX
SUPPLY
AS REQ.

152mm

(6)

PILOT

HOLES

102mm

(4)

324mm

(12-3/4)

SPONGE

WASHER

TANK MTG.

BOLTS

NUT

WASHER

NEOPRENE

SEAL

SEALANT

5

4

6

8

7

INSTALL NEOPRENE OR 
GRAPHITE FELT SEAL*

Install seal evenly around waste 
flange (horn).  Apply a thin bead of 
sealant around base flange.
* Note:  Wax seal not recommended 
for this application.

INSTALL TOILET ON FLANGE

a.  Unplug wall waste opening and slide toilet towards closet
 

flange so bolts project through mounting holes.

b.  Loosely install retainer tapered washers and nuts. Side of
 

washers marked "THIS SIDE UP" 

must 

face you!

INSTALL TOILET

a.  Position toilet squarely to wall and, with a rocking motion,
  

push bowl against ring and flange.

    Alternately tighten nuts until toilet is firmly anchored.

CAUTION: DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b.  Insert the tapered washers (supplied in the kit) into the 
 

lag bolts (not supplied). Insert bolts through mounting holes

 

and tighten into pre-drilled floor openings.

c.  Install the four bolt caps on tapered washers.  (If necessary,
      cut wall bolt length to size before installing caps.)    
d.  Smooth off the bead of sealant around base. Remove excess
 

sealant.

INSTALL TANK

a.  Install large rubber gasket over threaded
 

outlet on bottom of tank and lower tank

 

onto bowl so that tapered end of gasket

 

fits evenly into bowl water inlet opening,

 

and tank mounting bolts go through

 

mounting holes. Secure with metal

 

washers and nuts.

b.  With tank parallel to wall, alternately
 

tighten nuts until tank is snugged down

 

evenly against bowl's sanitary ribs.

CAUTION: DO NOT OVERTIGHTEN

NUTS MORE THAN REQUIRED

FOR A SNUG FIT!

INSTALL TOILET SEAT  

Install toilet seat in accordance with manufacturer's directions.

LAG

BOLT

BOLT HEAD

WASHER

TAPERED

WASHERS

FLANGE

BOLT

CAP

FLANGE

BOLTS

!

!

- 2 -

730419-100 Rev. D 

BOLT

CAP

NUT &

WASHER

9

11

12

10

CONNECT WATER SUPPLY

a.  Connect water supply line between  
 

shutoff valve and tank water inlet  

 

fitting. Tighten coupling nuts  

 

securely. 

b.  Turn on supply valve and allow
 

flushometer tank to fill.

c.  Check for leakage at fittings,
 

tighten or correct as needed.

CARE AND CLEANING 

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth.  
Avoid detergents, disinfectants, or cleaning products in aerosol cans.  NEVER use abrasive scouring powders or 
abrasive pads on your toilet seat.  Some bathroom chemicals and cosmetics may damage the seat's finish.

REPAIR PARTS LIST

NOTE: "XXX" and "YYY" represent color or trim finish options.

          Specify when ordering.

TANK

COUPLING NUT

FLEXIBLE
SUPPLY

WATER INLET

COMPRESSION
COLLAR

WASHER

VALVE NUT

TRIM PLATE

VALVE

4

11

- 3 -

730419-100 Rev. D

AMERICAN-STANDARD ONE-YEAR LIMITED WARRANTY

If  inspection  of  this  American-Standard  plumbing  product,  within  one  year  after  its  initial  installation,  confirms  that  it  is  defective  in  materials  or 

workmanship, American-Standard will repair or, at its option, exchange the product for a similar model. 

This warranty

 does not apply to local building code compliance.  Since local building codes vary considerably, the purchaser of this product should 

check with a local building or plumbing contractor to insure local code compliance before installation.

This warranty 

shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, 

misuse,  accident  or  other  damage;  if  it  was  not  installed  in  accordance  with  American-Standard's  instructions;  or  if  it  has  been  modified  in  a  manner 
inconsistent with the product as shipped by American-Standard.

American-Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, 

nor 

shall American-Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or 

exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or provinces do not allow the exclusion or 
limitation of implied warranties, so this exclusion may not apply to you.)

This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case 

this warranty does not affect such statutory rights.

For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or 
that a service request (including a description of the product  model and of the defect) be sent  to the following address:

- 4 -

TROUBLESHOOTING GUIDE

NOTE:   The presence of a small amount of water in the bottom of the tank is normal. The air inducer is designed to leak 

for short periods during each flush cycle as a self-cleaning action.  Drippage is drained into the bowl. If used on water 

system containing excessive sand and/or debris, a periodic cleanup of inlet strainer is recommended. (See enclosed    

    instructions for strainer cleaning.) 

  

!     WARNING

When servicing  or replacing components of the flushometer tank system, be sure that the

water supply is shut off and the toilet is flushed to relieve pressure in the flushometer tank.

For service of the Flushometer Tank System, see enclosed literature.

 

    PROBLEM                 POSSIBLE CAUSE                                                  CORRECTIVE ACTION

 Does not flush 

a.    Water supply valve closed. 

a.   Open valve and allow water to fill tank.

 

b.    Flush actuator incorrectly set. 

b.   Follow instruction to adjust flush actuator.

 

c.    Supply line blocked. 

c.   Shut off water supply, disconnect supply line, and inspect

 

 

 

 

all gaskets and washers.  Reassemble.

 

d.  Trip lever linkage damaged. 

d.   Check trip lever, linkage, and actuator wire assemblies

 

 

 

 

for damage.

Poor or sluggish 

a.   Supply valve partly closed. 

a.   Open supply valve fully.  Be sure that proper supply tube

flush 

 

      

 

size is used.

 

b.  Plugged inlet strainer. 

b.  Remove and clean strainer per enclosed instructions

 

c.    Supply pressure too low. 

c.   Normal supply pressure must be at least 20 psi.

 

d.    Partially clogged trapway and/or 

d.   Remove obstruction.  Consult a plumber if necessary.

 

       drain pipe and/or vent.

 

e.    Malfunctioning pressure regulator. 

e.   Replace lower supply assembly.

Toilet leaks 

a.    Poor supply line connection. 

a.   Review Step 9 of installation procedure.

 

b.    Poor bowl to tank/floor connection.  b.   Review Step 4 through 7 of installation procedure.

Toilet does not 

a.    Supply pressure too low. 

a.   Normal supply pressure must be at least 20 psi.

shut off 

b.    Flush actuator incorrectly set. 

b.   Follow instructions to adjust flush actuator.

730419-100 Rev. D

In Canada:

American-Standard, 

2480 Stanfield Road

Mississauga, Ontario 

Canada L4Y 1S2

Toll Free:  (800) 387-0369

Toronto Area:  (905) 949-4800

In Mexico:  

Customer Service Manager

Ideal Standard, S.A. de C.V.

Via Morelos #330

Col. Santa Clara

Ecatepec 55540 Edo. Mexico

ADJUSTMENTS

The flushometer tank is designed and factory-adjusted to provide a 
consistent, safe seal depth in the bowl after each flush.  Field refill 
adjustment is not required.  The refill has been preset and locked.
  
FLUSH ACTUATOR ADJUSTMENT - The spacing between the bellcrank 
and flush actuator may be adjusted to assure positive operation of the trip 
lever.  Proceed as follows:

n

  Remove tank cover and check that there is approximately 1/32"

 

(0.8mm) gap between the top of the actuator and bottom of the spring  

 

rod when it is lifted to remove slack from linkage.

n

  If necessary, loosen set screw in actuator cap and turn cap to increase

 

gap (clockwise) or decrease gap (counterclockwise), as needed.

n

  Tighten setscrew securely after adjustment is completed.  Replace

 

tank cover.

SET

SCREW

1/32"
APPROX.

ITEM

PART NO.

DESCRIPTION

QTY

1

2

3
4

5

6
7
8
9

10
11

1

1

1
1
1
1

1
1
1
1
1
2

1
1

738473-YYY0A
738494-YYY0A
4099.100.XXX

4099.800.XXX

735084-400.XXX
3120.019.XXX
3125.016.XXX
738493-0070A
738495-0070A
034602-0070A
738496-0070A
047562-0070A
047563-0070A
730292-0070A
034783-XXX0A

735083-600.XXX
603111-0030A

TRIP LEVER-LH
TRIP LEVER-RH
TANK (COMPLETE WITH COUPLING
COMPONENTS AND L.H. TANK TRIM)
TANK (COMPLETE WITH COUPLING
COMPONENTS AND R.H. TANK TRIM)
TANK COVER
BOWL - ELONGATED
BOWL - ELONGATED 16-1/8" (410mm)
SPRING ROD ASSEMBLY-LH
SPRING ROD ASSEMBLY-RH
COUPLING GASKET
LOWER SUPPLY ASSEMBLY (35 PSI)
UPPER SUPPLY ASSEMBLY
VALVE CARTRIDGE ASSEMBLY
TANK COUPLING KIT
BOLTS AND CAPS

TANK COVER FOR LOCKING DEVICE
COVER LOCKING DEVICE KIT

1

2

3

5

8

9

7

 6 

 10

In the United States:

American Standard Inc.,

P.O. Box 6820

Piscataway, New Jersey 08855

Attention: Director of  Consumer Affairs

For residents of the United States, warranty information 

may also be obtained by calling the following 

toll free number: (800) 442-1902

www.AmericanStandard-US.com

Summary of Contents for Yorkville 2320 Elongated

Page 1: ...ve closet bolts from flange and clean away old wax putty etc from base area NOTE Mounting surface must be clean and perpendicular to the floor before new toilet is installed INSTALL CLOSET BOLTS Install closet bolts in flange channel turn 90 and slide into place 6 152 mm apart and parallel to floor Use putty to hold bolts in place if necessary Brace under flooring as needed and drill two mounting ...

Page 2: ...ed in the kit into the lag bolts not supplied Insert bolts through mounting holes and tighten into pre drilled floor openings c Install the four bolt caps on tapered washers If necessary cut wall bolt length to size before installing caps d Smooth off the bead of sealant around base Remove excess sealant INSTALL TANK a Install large rubber gasket over threaded outlet on bottom of tank and lower ta...

Page 3: ...tween the bellcrank and flush actuator may be adjusted to assure positive operation of the trip lever Proceed as follows n Remove tank cover and check that there is approximately 1 32 0 8mm gap between the top of the actuator and bottom of the spring rod when it is lifted to remove slack from linkage n If necessary loosen set screw in actuator cap and turn cap to increase gap clockwise or decrease...

Page 4: ... cycle as a self cleaning action Drippage is drained into the bowl If used on water system containing excessive sand and or debris a periodic cleanup of inlet strainer is recommended See enclosed instructions for strainer cleaning WARNING When servicing or replacing components of the flushometer tank system be sure that the water supply is shut off and the toilet is flushed to relieve pressure in ...

Reviews: