American Standard Two-Piece Toilets With Aquameter Fill Valve 2264.702 Installation Instructions Download Page 1

RECOMMENDED TOOLS AND MATERIALS

Putty Knife

Regular Screwdriver

Adjustable Wrench

Sealant

Tape Measure

Hacksaw

Wax Ring/Gasket

Flexible Supply Tube

Closet Bolts

Carpenters Level

1

   REMOVE OLD TOILET

a.

Close toilet supply valve and flush tank completely.  Towel or sponge remaining water from tank and bowl.

b.

Disconnect and remove supply line.  NOTE:

 If replacing valve, first shut off main water supply!

c.

Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.

d.

Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
NOTE: 

 Mounting surface must be clean and level

 before

 new toilet is installed!

INSTALL CLOSET BOLTS

Install closet bolts in flange channel, turn 90˚,
and slide into place 6" (152 mm) apart and
parallel to wall.

S

A

V

E

 

F

O

R

 

F

U

T

U

R

E

 

U

S

E

3

2

ROUGHING-IN DIMENSIONS:  

NOTE: 

 Distance from wall to closet flange centerline must

be as listed below:

CLOSET FLANGE

CLOSET BOLTS

730489-100 Rev. B

12"

(305mm)

FINISHED WALL

FINISHED 

FLOOR

Saniwares

   CAUTION:  PRODUCT IS FRAGILE.  TO AVOID BREAKAGE AND POSSIBLE INJURY
   HANDLE WITH CARE!

NOTE:  

Pictures may not exactly define contour of china and components.

 

!

REPERTOIRE 2266/2483
HERITAGE 2176
ANTIQUITY 2264/2464
WILLIAMSBURG 2264.702

Thank you  for selecting American Standard - the benchmark of fine quality for over 100 years.  To ensure this
product is installed properly, please read these instructions carefully before you begin. (Certain installations may
require professional help.) Also be sure your installation conforms to local codes

INSTALLATION INSTRUCTIONS

 

For Two-Piece Toilets with Aquameter™ Fill Valve

SUPPLY AS

REQUIRED

12

(305mm)

P r o d u c t   n a m e s   l i s t e d   h e r e i n   a r e   t r a d e m a r k s   o f   A m e r i c a n   S t a n d a r d   I n c .
©   A m e r i c a n   S t a n d a r d   I n c .   2 0 0 6

WAX RING

SEALANT

5

4

7

6

INSTALL WAX SEAL

Invert toilet on floor (cushion to prevent 
damage), and install wax ring evenly around 
waste flange (horn), with tapered end of ring 
facing toilet.  Apply a thin bead of sealant
around base flange.

POSITION TOILET ON FLANGE

a. Unplug floor waste opening and install toilet on closet flange
so bolts project through mounting holes.
b. Loosely install mounting clip (for Heritage only), retainer 
washers and nuts. Side of washers marked "THIS SIDE UP" 
must face up!
c. Position toilet squarely to wall and, with a rocking motion, 
press bowl down fully on wax ring and flange. Alternately tighten 
nuts until toilet is firmly seated on floor.

CAUTION: 

DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b. Install covers on washers.  (If necessary, cut bolt height to 
size before installing caps.)  
c. Smooth off the bead of sealant around base. Remove excess 
sealant.

INSTALL TANK

a. Install large rubber gasket over 
threaded outlet on bottom of tank and 
lower tank onto bowl so that tapered 
end of gasket fits evenly into bowl 
water inlet opening.
b. Insert tank mounting bolts and 
rubber washers from inside tank, 
through mounting holes, and secure 
with metal washers and nuts.
c. With tank parallel to wall, 
alternately tighten nuts until tank is 
snugged down evenly against bowl 
surface.

INSTALL TOILET SEAT  

Install toilet seat in accordance with 
manufacturer's directions.

WASHER

MOUNTING

CLIP

NUT

NUT

CLOSET

BOLT

CLOSET

BOLT

WASHER

HERITAGE

REPERTOIRE, ANTIQUITY,

& WILLIAMSBURG

BOLT CAP

BOLT CAP COVER

RUBBER 

GASKET

TANK MTG.

BOLTS

NUT

WASHER

 FLANGE

!

- 2 -

!

CAUTION:  

DO NOT OVERTIGHTEN NUTS MORE

THAN REQUIRED FOR A SNUG FIT!

RUBBER

WASHER

730489-100 Rev. B

730489-100 Rev. B

730489-100 Rev. B

- 3 -

8

11

9

ADJUSTMENTS

a. Flush tank and check that tank fills and shuts off within 30 to 60 seconds, and 

tank water level is set as specified on tank rear wall.

b. To adjust water level: turn water level adjustment screw counterclockwise to 

raise level; turn adjustment screw clockwise to lower level. 

c. To adjust flow rate (tank fill time): turn flow rate adjustment screw clockwise to 

decrease flow rate (increase fill time); turn adjustment screw counterclockwise to 

increase flow rate (decrease fill time).

d. Carefully position tank cover on tank.

e. The flush valve float has been factory set and does not require adjustments. 

Repositioning of the float will change the amount of water used which may effect 

the toilet's performance.

f.

If bowl fails to siphon, an adjustment may be required with the lift chain.  Simply 

remove the bead chain from the retainment clip (see Fig. 10A) and take up slack 

on the chain, and reinsert on lift rod.  Make sure the chain is not too taught.

CARE AND CLEANING

When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth.  Avoid 
detergents, disinfectants, or cleaning products in aerosol cans.   NEVER use abrasive scouring powders or abrasive pads 
on your toilet seat.  Some bathroom chemicals and cosmetics may damage the seat's finish.

WARNING:

 Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings 

in the tank. This damage can cause leakage and property damage.

American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners 

containing chlorine (calcium hypochlorite). 

REPAIR PARTS LIST

FOR 4094 ANTIQUITY, 4095 REPERTOIRE, AND

4094.702 WILLIAMSBURG

FOR 4074.039 HERITAGE

NOTE: 

"XXX" represents color or trim finish options. Specify when ordering.

Repair parts are determined by toilet tank number which can be found marked inside tank.

PART NO.

DESCRIPTION

PART NO.

DESCRIPTION

730288-XXX0A
730535-XXX0A
034783-XXX0A

738462-0070A
738181-0070A
047158-0070A
738258 -0070A

TRIP LEVER
TRIP LEVER (WILLIAMSBURG ONLY)
BOLT CAP KIT (INCL 2 COVERS & 
    WASHERS) 
WATER CONTROL ASS'y W FLOAT BALL 
FLUSH VALVE
COUPLING KIT, BOWL-TO-TANK
FLAPPER ASSEMBLY

730283-XXX0A
047227-XXX0A
738352-0070A
738181-0070A
047158-0070A
738258 -0070A

TRIP LEVER
BOLT CAP COVER PLATE KIT #207
WATER CONTROL ASS'y W FLOAT BALL 
FLUSH VALVE
COUPLING KIT, BOWL-TO-TANK
FLAPPER ASSEMBLY

TANK

COUPLING NUT

FLEXIBLE
SUPPLY

WATER INLET

COMPRESSION
COLLAR

WASHER

VALVE NUT

TRIM PLATE

VALVE

C L

TO RAISE 

WATER

LEVEL

FLAPPER

ASSEMBLY

TO LOWER 

WATER

LEVEL

TRIP

LEVER

FLUSH VALVE

WATER INLET

OVERFLOW

TUBE

FIG. 10A

WATER LINE

LEVEL

+

WATER CONTROL

ASSEMBLY

-

FLOW RATE

ADJUSTMENT

REFILL

TUBE

LIFT

ROD

FLOAT

BALL

FLUSH

VALVE

FLOAT

!

TROUBLESHOOTING GUIDE

 

    PROBLEM                 POSSIBLE CAUSE                                                  CORRECTIVE ACTION

Does not flush

a. Water supply valve closed.

a. Open valve and allow water to fill tank.

b. Supply line blocked.

b. Shut off water supply, disconnect supply line, and inspect

     

all gaskets and washers.  Reassemble.

c.  Flush valve chain too loose or

c. Readjust chain length as required.

     disconnected.

d.  Stuck float/float rod.

d. Adjust to allow free downward movement of float arm.

e.  Water control flow rate too

e. Follow instructions to increase water control flow rate.

     restricted. 

Poor or 

a.  Tank water level too low.

a. Follow instructions to adjust water level.

sluggish flush

b.  Bowl water level too low.

b.  Check that refill tube is connected to water control and

inserted into tank overflow without being kinked or damaged.

c.  Supply valve partly closed.

c.  Open supply valve fully.  Be sure that proper supply tube 

size is used.

d.  Flush valve closes early due to high

d.  Follow instructions to reduce water control flow rate.

     supply pressure.

 

e.  Partially clogged trapway and/or

e.  Remove obstruction.  Consult a plumber if necessary.

     drain pipe and/or vent.

f.   Supply pressure too low.

f.   Normal supply pressure must be at least 20 psi.

Toilet leaks

a.  Poor supply line connection.

a.  Review Step 9 of installation procedure.

b.  Poor bowl to tank/floor connection.

b.  Review Step 4 through 7 of installation procedure.

Toilet does not

a.  Tank water level too high.

a.  Follow instructions to adjust water level.

shut off

b.  Float rod or float ball depressed by

b.  Readjust float rod.

     tank cover.

c.  Flush valve chain too tight, holding

c.  Readjust chain length as needed.

     flush valve open.

d.  Float rod interfering with flush valve

d.  Follow installation instructions to reduce water control flow

closing.

rate, which will lift lowest position of float rod without

affecting water level.

e.  Flush valve seat and/or flapper worn

e.  Replace flapper/flush valve assembly, as needed.

     or deformed.

f.   Sand or debris lodged in water 

f.   Shut off water supply.  Consult a plumber, if necessary.

control.

 Noisy Flush

a.  Water control flow rate too restricted. a. Follow instructions to increase water control flow rate.

- 4 -

AMERICAN-STANDARD ONE-YEAR LIMITED WARRANTY

If  inspection  of  this  American-Standard  plumbing  product,  within  one  year  after  its  initial  installation,  confirms  that  it  is  defective  in  materials  or 

workmanship, American-Standard will repair or, at its option, exchange the product for a similar model. 

This warranty

 does not apply

 to local building code compliance.  Since local building codes vary considerably, the purchaser of this product should 

check with a local building or plumbing contractor to insure local code compliance before installation.

This warranty 

shall be void

 if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse, 

misuse,  accident  or  other  damage;  if  it  was  not  installed  in  accordance  with  American-Standard's  instructions;  or  if  it  has  been  modified  in  a  manner 
inconsistent with the product as shipped by American-Standard.

American-Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, 

nor 

shall American-Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or 

exchange of a defective product, all of which are expressly excluded from this warranty.

 (Some states or provinces do not allow the exclusion or 

limitation of implied warranties, so this exclusion may not apply to you.)

This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case 

this warranty does not affect such statutory rights.

For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or 
that a service request (including a description of the product  model and of the defect) be sent  to the following address:

In the United States:

American Standard Inc.

P.O. Box 6820

Piscataway, New Jersey 08855

Attention: Director of  Consumer Affairs

For residents of the United States, warranty 

information may also be obtained by calling 

the following toll free number: (800) 442-1902

In Canada:

American Standard

2480 Stanfield Rd.  

Mississauga, Ontario 

Canada L4Y 1S2

Toll Free:  (800) 387-0369

In Mexico:

Customer Service Manager 

Ideal Standard, S.A. de C.V.

Via Morelos #330

Col. Santa Clara

Ecatepec 55540 Edo. Mexico

www.AmericanStandard-US.com

www.AmericanStandard.ca

www.AmericanStandard.com.mx

CAUTION: Overtightening of 

COUPLING NUT could result in 

breakage and potential flooding.

CONNECT WATER SUPPLY

a.  Connect water supply line between   
 

shutoff valve and tank water inlet 

 

fitting. T

ighten COUPLING NUT 1/4 turn  

 

beyond hand tight.

 Check that refill tube  

 

is inserted into overflow tube.

b.  Turn on supply valve and allow tank to  
 

fill until float rises to shutoff position.

c.  Check for leakage at fittings, tighten or  
 

correct as needed.

d.  Do not use plumber's putty to seal           
 

these fittings.

Summary of Contents for Two-Piece Toilets With Aquameter Fill Valve 2264.702

Page 1: ...U T U R E U S E 3 2 ROUGHING IN DIMENSIONS NOTE Distance from wall to closet flange centerline must be as listed below CLOSET FLANGE CLOSET BOLTS 730489 100 Rev B 12 305mm FINISHED WALL FINISHED FLOOR Saniwares CAUTION PRODUCT IS FRAGILE TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE NOTE Pictures may not exactly define contour of china and components REPERTOIRE 2266 2483 HERITAGE 2176 ANT...

Page 2: ...ll covers on washers If necessary cut bolt height to size before installing caps c Smooth off the bead of sealant around base Remove excess sealant INSTALL TANK a Install large rubber gasket over threaded outlet on bottom of tank and lower tank onto bowl so that tapered end of gasket fits evenly into bowl water inlet opening b Insert tank mounting bolts and rubber washers from inside tank through ...

Page 3: ... shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing chlorine calcium hypochlorite REPAIR PARTS LIST FOR 4094 ANTIQUITY 4095 REPERTOIRE AND 4094 702 WILLIAMSBURG FOR 4074 039 HERITAGE NOTE XXX represents color or trim finish options Specify when ordering Repair parts are determined by toilet tank number which can be found marked inside tank PART ...

Page 4: ...merican Standard plumbing product within one year after its initial installation confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local building ...

Reviews: