American Standard Town Square T555740 Installation Instructions Manual Download Page 1

M962636-YYY0A

VOLUME CONTROL HANDLE

T555740

TOWNSQUARE

TOWNSQUARE

Installation

Instructions

M 9 6 8 6 5 9

M 9 6 8 6 5 9

M 9 6 8 6 5 9

M 9 6 8 6 5 9

Thank you for selecting American-Standard...the benchmark

of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--please

read these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1M
ASSE 1016

ROUGHING-IN DIMENSIONS

MODEL NUMBER

CHROME

BLACKENED BRONZE (PVD)

SATIN NICKEL (PVD)

002

068

295

Replace the "YYY" with

appropriate finish code

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1-800 442-1902

Weekdays 8:00 a.m. to 8:00 p.m. EST

IN CANADA  1-800-387-0369   (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of American Standard Inc.

Recommended Tools

Flat Blade Screwdriver

Phillips Screwdriver

Remove as much surface dirt and film using clear 

water and soft cotton cloth (as described above).

 

     Use any of the following to remove tough surface 

     film and build-up:

     Mild liquid detergents

     Clear ammonia free liquid glass cleaners

     Non-acidic, non-abrasive gentle liquid or fully

     dissolved powder cleansers mixed according to

     manufacturers directions.

     Non-abrasive liquid polishers

Once clean, rinse faucet again with clear water to 

thoroughly remove cleaner or polish and blot dry with

a soft cotton cloth. 

To keep your new faucet looking new, please follow

these simple care instructions:

DO:     Simply rinse the faucet clean with clear water.

           Dry the faucet with a soft cotton cloth.

DO NOT: 

           Do not use any abrasive cleaners, cloths, or 

           paper towels.

           Do not use any cleaning agents containing

           acids, polish abrasives, or harsh cleaners or

           soaps.

Regular and routine cleaning will reduce the need for

heavy cleaning and polishing. If heavy cleaning is

required, the following procedures are recommended:

CARE INSTRUCTIONS:

Failure to follow these care instructions may

damage the Faucet's finish.

A907090-YYY0A

CAP

1

Remove PLASTER GUARD (1) if attached.

Push CAPS (2 & 2a) as shown onto CONTROL

VALVES (3).

Push ESCUTCHEON (4) over CAPS (2, 2a) and

flush against finished wall. Attach with the two

SCREWS (5) provided.  

4

4

4

TEMPERATURE ADJUSTMENT

SET HOT LIMIT STOP

Check that arrow marking B points to the 3 o'clock position. If not, push the BLACK CLAMP on the SECURING RING to

the right, pull off KNOB MOUNT (4) and reinstall KNOB MOUNT (4) with arrow "B" 3 o'clock position. 

See Figure 1.

For 100˚F adjustment, turn the water supply on. Turn KNOB MOUNT (4) until the spout temperature is 100˚F. Check

that arrow "A" on the KNOB MOUNT (4) still points 3 o'clock position after adjusting the thermostat to 100˚F.

If not, pull out the RED LOCKING DEVICE. Remove KNOB MOUNT (4) by pulling it towards you while standing directly in

front of the valve.

Reinstall the KNOB MOUNT (4) with arrow "A" 3 o'clock position.

The maximum mixed water temperature is set at 109˚F at the factory. This setting can be changed if desired.

Remove the TEMPERATURE LIMIT STOP (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in

the diagram to limit the maximum mixed water temperature to 104˚F or 112˚F.

Reinstall RED LOCKING DEVICE.

See step 3 for HANDLE (3) installation.

Pull out index CAP (1) and remove HANDLE SCREW (2). Pull off HANDLE ASSEMBLY (3).

ARROW

"A"

BLACK

CLAMP

ARROW

"B"

RED LOCKING

DEVICE

TEMPERATURE

LIMIT STOP

ARROWS AT 3 O'CLOCK

POSITION

Figure 1

KNOB MOUNT

112 

109 

104 

1

TRIM INSTALLATION

2

INSTALL HANDLES

Should the hot and cold water supply pipes have been transposed making

adjustment impossible, proceed as follows:

TRANSPOSED SUPPLY PIPING

OR BACK TO BACK INSTALLATION

3

Remove check stops and re-install them transposed.

Shut off water supply.
Remove handle and rim. (Reverse steps 1 and 2.

CHECK STOP

(RED TO BLUE)

Turn the water supply back on and perform the temperature adjustment in step 4.
Assemble HANDLES and TRIM.

CHECK STOP

(BLUE TO RED)

Important note: RED CHECK STOP is now on the right of the mixer body and the BLUE

CHECK STOP is now on the left.

CENTRAL THERMOSTAT

WITH VOLUME CONTROL

TRIM KIT

1

8

1

5

9

10

11

3

4

6

2

2a

3

TOP

 

1

5

7

Align HANDLE BASE (1) and push onto KNOB MOUNT (2).

Install LEVER HANDLE (3) as shown. Install HANDLE SCREW (4) and

tighten with screwdriver.

Push INDEX CAP (5) into HANDLE (3).

Install HANDLE ADAPTER (6) onto VALVE STEM (7).

Install HANDLE SCREW (8) and tighten.

Push VOLUME CONTROL KNOB (9) onto HANDLE ADAPTER (6).

Use HEX WRENCH (10) supplied and tighten set screw to secure 

VOLUME CONTROL KNOB (9).

Push in PLUG BUTTON (11)

2

M962635-YYY0A

ESCUTCHEON AND SCREWS

A918434-YYY0A

ESCUTCHEON SCREWS

M962633-YYY0A

HANDLE SCREW

AND INDEX BUTTON

M908587-YYY0A

HANDLE BASE

M916815-YYY0A

LEVER HANDLE

© AS America, Inc. 2007

CENTRAL THERMOSTAT

WITH VOLUME CONTROL

TRIM KIT

186mm

(7-3/8)

100mm

(3-7/8)

230mm

(9)

230mm

(9)

48mm to 68mm

(2 to 2-5/8)

150mm

(6)

NOTE: FITTING 

MUST BE INSTALLED

WITH VOLUME CONTROL 

ON TOP.

R520

1/2" NPT INLETS

or

R540

3/4" NPT INLETS

25mm

(1)

FINISHED

WALL

190mm

(7-1/2)

4

2

3

T555740

Summary of Contents for Town Square T555740

Page 1: ...olishers Once clean rinse faucet again with clear water to thoroughly remove cleaner or polish and blot dry with a soft cotton cloth To keep your new faucet looking new please follow these simple care instructions DO Simply rinse the faucet clean with clear water Dry the faucet with a soft cotton cloth DO NOT Do not use any abrasive cleaners cloths or paper towels Do not use any cleaning agents co...

Page 2: ...ps 1 and 2 CHECK STOP RED TO BLUE Turn the water supply back on and perform the temperature adjustment in step 4 Assemble HANDLES and TRIM CHECK STOP BLUE TO RED Important note RED CHECK STOP is now on the right of the mixer body and the BLUE CHECK STOP is now on the left 1 8 5 9 10 11 3 4 6 2 2a 3 TOP 1 5 7 Align HANDLE BASE 1 and push onto KNOB MOUNT 2 Install LEVER HANDLE 3 as shown Install HAN...

Page 3: ...E Remove KNOB MOUNT 4 by pulling it towards you while standing directly in front of the valve Reinstall the KNOB MOUNT 4 with arrow A 3 o clock position The maximum mixed water temperature is set at 109 F at the factory This setting can be changed if desired Remove the TEMPERATURE LIMIT STOP H shaped Black Plastic part Reinstall it at the desired notch as indicated in the diagram to limit the maxi...

Page 4: ...00 442 1902 Weekdays 8 00 a m to 8 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc A907090 YYY0A CAP M962635 YYY0A ESCUTCHEON AND SCREWS A918434 YYY0A ESCUTCHEON SCREWS M962633 YYY0A HANDLE SCREW AND INDEX BUTTON M908587 YYY0A HANDLE BASE M916815 YYY0A LEVER HANDLE AS America Inc 2007 C...

Page 5: ...G A DIVERTER SPOUT A SEPARATE DIVERTER VALVE MUST BE USED NOTE MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI TUB PORT MUST BE PLUGGED HOT 1 2 1 2 COLD TUB PORT MUST BE PLUGGED HOT 1 2 1 2 COLD THERMOSTATIC BATH SHOWER INSTALLATION USING A TWIN ELL DIVERTER SPOUT AND FIXED SHOWER THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE F...

Page 6: ...emove the TEMPERATURE LIMIT STOP H shaped Black Plastic part Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F Reinstall RED LOCKING DEVICE KNOB MOUNT ARROW A BLACK CLAMP ARROW B RED LOCKING DEVICE SECURING RING 104 109 112 TEMPERATURE LIMIT STOP TOP CHECK STOP HOT RED PLUG TUB PORT CHECK STOP COLD BLUE COLD HOT 1 3 2 4 WOO...

Page 7: ...3 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2003 923348 0070A HANDLE ADAPTER 994053 0070A CARTRIDGE 953960 0070A THERMOSTAT CARTRIDGE 912647 0070A O RING 953963 0070A HANDLE EXTENSION 953957 0070A TEMPERATURE CALIBRATION UNIT 953950 0070A CHECK STOP COLD BLUE 953951 0070A CHECK STOP HOT RED A918572 0070A CARTRIDGE SC...

Page 8: ... SEPARATE DIVERTER VALVE MUST BE USED NOTE MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI TUB PORT MUST BE PLUGGED HOT 3 4 3 4 COLD TUB PORT MUST BE PLUGGED HOT 3 4 3 4 COLD THERMOSTATIC BATH SHOWER INSTALLATION USING A TWIN ELL DIVERTER SPOUT AND FIXED SHOWER THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE FIXED SHOWER HEAD AND...

Page 9: ...he TEMPERATURE LIMIT STOP H shaped Black Plastic part Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F Reinstall RED LOCKING DEVICE KNOB MOUNT ARROW A BLACK CLAMP ARROW B RED LOCKING DEVICE SECURING RING 104 109 112 TEMPERATURE LIMIT STOP M968480 TOP CHECK STOP HOT RED PLUG TUB PORT CHECK STOP COLD BLUE COLD HOT 3 2 4 WOOD...

Page 10: ... 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2003 923348 0070A HANDLE ADAPTER A994352 0070A CARTRIDGE 954040 0070A THERMOSTAT CARTRIDGE 912647 0070A O RING 953963 0070A HANDLE EXTENSION 953957 0070A TEMPERATURE CALIBRATION UNIT A953971 0070A CHECK STOP COLD BLUE A953972 0070A CHECK STOP HOT RED 918428 0070A CARTRIDGE SCREW 963434...

Reviews: