J47
© 2006 American Standard Inc.
FINISHED WALL
OR SPLASHBACK
OVERFLOW
180mm
(7-5/8)
51mm
(2) MIN.
EDGE OF
COUNTER
TOP
CUTOUT
A
B
MOUNTING
CLIP
(SEE DETAIL)
C/L OF
OUTLET
25mm
(1)
464mm
(18-1/4)
76mm
(3)
381mm
(15)
41mm
(1-5/8)
DETAIL OF MOUNTING CLIP
(KIT No.47194.0070A)
LAVA
BRASS
INSERT
19mm
(3/4) MIN.
REFER TO INSTRUCTIONS
PROVIDED WITH KIT FOR
ADDITIONAL INFORMATION
CLIP
MACH.
SCREW
1-1/4 O.D.
TAILPIECE
1-1/4 O.D.
WASTE
203mm
(8)
343mm
(13-1/2)
273mm
(10-3/4)
19mm
(3/4)
197mm
(7-3/4)
SUPPLIES
AS REQ'D.
COUNTERTOP
(BY OTHERS)
SEALING
COMPOUND
787mm (31)
864mm (34)
*
*
FINISHED FLOOR
16mm
(5/8)
FITTING
CENTER-SET
SPREAD
A
27mm(1-1/16)
32mm(1-1/4)
B
102mm(4)
203mm(8)
45°
C/L
686mm
(27)
MIN.
864mm
(34)
76mm
(3)
610mm
(24)
BARRIER FREE
CLEARANCE
152mm
(6)
MAX.
229mm
(9)
MIN.
203mm
(8)
MIN.
DRAWING FOR
DIMENSIONAL
PURPOSES ONLY.
IT IS NOT AN EXACT
REPRESENTATION.
GLENDALE™
UNDERCOUNTER SINK
VITREOUS CHINA
BARRIER FREE
To Be Specifi ed:
❏
Color:
❏
Faucet*:
❏
Faucet Finish:
❏
Supplies:
❏
1-1/4" Trap:
* See faucet section for additional models available
NOTES:
*
DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP ARE
SUGGESTED.
▼
UNDERCOUNTER MOUNTING KIT SUPPLIED WITH SINK.
FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED
SEPARATELY.
IN-FIELD ADJUSTMENT OF POP-UP ROD EXTENSION REQUIRED. PROVIDE A
2-1/2" OFF-SET BEND FOR PROPER OPERATION.
USE ENCLOSED TEMPLATE FOR COUNTERTOP CUTOUT.
SEALING COMPOUND SUPPLIED BY OTHERS.
IMPORTANT:
Dimensions of fi xtures are nominal and may vary within the range of
tolerances established by ANSI Standard A112.19.2. These measurements are
subject to change or cancellation. No responsibility is assumed for use of
superseded or voided pages.
GLENDALE™ UNDER COUNTER SINK
• Shell style pattern in bowl
• Made from vitreous china
• Unglazed rim for undermount
• Front overfl ow with option of rear overfl ow
installation for Barrier Free
• Center drain outlet
• Supplied with mounting kit (047194-0070A)
and
template
❏
0625.000
464 x 381mm
(18-1/4" x 15")
Bowl Sizes:
406mm (16") wide
311mm (12-1/4") front to back
152mm (6") deep
Compliance Certifi cations -
Meets or Exceeds the
Following Specifi cations:
• ASME A112.19.2M for
Vitreous China Fixtures
Revised 5/06
MEETS THE AMERICANS WITH DISABILITIES ACT
GUIDELINES AND ANSI A117.1 ACCESSIBLE AND
USABLE BUILDINGS AND FACILITIES -
CHECK LOCAL CODES.
With overfl ow to the rear and countertop 864mm (34”)
from fi nished fl oor. Lavatory installed 51mm (2”) MIN.
from front edge of countertop. Countertop thickness to
be 25mm (1”) maximum.