American Standard Codie Installation & Operation Instructions Download Page 1

Rev.  A0 

- 1 -

- 4 -

FFASB221-609500BF0

In-Wall Bath & Shower Mixing Valve

FFASB221-609500BF0

FFASB222-709500BF0

FFASB222-709500BF0

In-Wall Shower Only Mixing Valve

2

1

42

46~56

184

65

11

24.5

134

G 3/4”

G 1/2”

G 1/2”

184

30~38 11

24.5

42

124

G 1/2”

G 1/2”

75

1

19

70

55

9

7

8

7

3

4

6

5

A

B

Codie

Codie

FFASB221-609500BF0

FFASB222-709500BF0

Unit:mm

Care & Maintenance

* If you want to do the maintenance
for the faucet, please follow the 
below process.

Attention:

Please Leave the manual with the customer 
after installation is finished.

1

2

Test / Usage

* Move handle down into “OFF”position.  Turn on supply angle valve to check allconnections for leak.
* Operate handle up and down, left and right to flush water lines thoroughly.

Test

Usage

Trouble Shooting Guide

Untwist the hose.

Cartridge packing

Hose junction

Check the connection.

Check cartridge install.

Check valve position.

Check any impurities.

Remove all impurities.

Open it to full valve

When packing is damaged, replace the cartridge.

Check the existence of packing and wind it up sufficiently

Poor flow rate

Leakage

Angle valve

Flexible hose

Regulator

Check if hose is twisted.

Check if the water from Supply valve is enough or not

Check if the supply pipe connected correct or not

Connect the hot and cold water pipe correctly

Increase water supply

Deviant 
Temperature

Supply Valve

Trouble

Checkpoint

Contents

Action

Supply system

(Cold)

ON

(Hot)

Dimension

Installation &

Operation Instructions

* Recommended water pressure condition:  0.1~0.5Mpa.

* Environment Temperature:1~55℃

* Steam is not allowed to use.

* The cold and hot water pipes must not be reserved.

Conditions for use

*Remove all impurity in pipes before beginning to avoid clogging.  Connect faucet pipes correctly.  

* Check installation distances in the Dimension diagram to ensure correct installation.

Make sure the cold water hose is connected to the right side and the hot water hose to the left.

When in the process of installation, grab the whole body.  Do not grab handle only.

Pre-Installation Checks

* American Standard always keep raising and improving the product design and performance, and reserve the right to modify
the dimension and spefication.  At this case, we will not inform you separately.
* This installation instruction sheet is for your reference only, the dimension and specification is subject to the actual products.

Thank you for selecting American-Standard - the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

All instruction procedures must comply in strict accordance with applicable local plumbing and building codes       

    

Recommended Tools and Materials

Pencil

Windtight Swathe

Adjustable Wrench

Level

Tape Measure

Screwdriver

Connect to Shower

Connect to Spout

       The inner diameter of pipe from 
body to spout (including connector) 
need to be more than 13mm

!

Connect to Shower

Wall

Wall