INSTALLATION INSTRUCTIONS
752874-100 Rev. C
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
CADET ELITE
CORNER™
WHIRLPOOL
2775E SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 223-0068 WEEKDAYS.
T H A N K Y O U . . .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Flex-Jet Pulse Jet Kit*
• Flex-Jet Soft Jet Kit*
• E-Z-Install Heater*
• Tile Bead Kit*
List of Required Components (not included):
• Drain* • Bath Filler*
* see your Home Depot Retailer
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 20 amp GFI
Outlet
• Cement, Plaster,
Grout
1524mm
(60)
70mm REF.
(2-3/4)
165mm
(6-1/2)
279mm
(11)
RECOMMENDED
FITTING LOCATION
64 X 330mm (2-1/2 X 13)
229 X 305mm
(9 X 12)
CUTOUT IN
FLOOR FOR
DRAIN
ON/OFF
SWITCH
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
OUTLINE OF
CUTOUT
2159mm
(85)
1080 mm
(42-1/2)
C/L
1524mm
(60)
1076mm
(42-3/8)
1080mm
(42-1/2)
PUMP
C/L OF
DRAIN OUTLET
1-1/2 O.D. TAILPIECE
LEVELING STRINGER
NOT FOR SUPPORT
70mm
(2-3/4)
117mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
38 mm REF.
(1-1/2)
C/L OF
OVERFLOW
76mm
(3)
464mm
(18-1/4)
502mm
(19-3/4)
ROUGH
FLOOR
INTEGRAL
SUPPORT
FEET
IN-LINE
HEATER
REMOVABLE
BLANK
85 X 60 X 19-3/4In.
(2159mm X 1524 mm X 502mm)
130 Lbs. (59 Kg.)
756 Lbs. (343 Kg.)
75 Gal. (284 L.)
60 Gal. (227 L.)
32 X 32 In. (813 mm X 813 mm)
46 X 46 In. (1168 X 1168mm)
14 In. (356 mm)
34 Lbs./Sq. Ft. (115 Kgs/Sq. m.)
41.7
70.4
GENERAL SPECIFICATIONS FOR 2775E WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
2.1 HP, 14.4 AMPS, 120V.
PUMP