Summary of Contents for ARSCT-244

Page 1: ...4GD ARSCT 364GR ARSCT 486GD ARSCT 486GR ARSCT 4842GD ARSCT 484X2GR ARSCT 6062GD ARSCT 6062GR ARSCT 606GDGR PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 888 753...

Page 2: ...1 Electrical Gas Locations 12 Electrical Gas Requirements 13 Gas Requirements 14 General Instructions 15 Installation Instructions 15 Installation Steps 16 19 Performance Check List 20 Final Preparati...

Page 3: ...Electrical Information ______________________________________ FOR YOUR SAFETY FOR YOUR SAFETY Instruction to be followed in the event the user smells gas should be posted in a prominent location This...

Page 4: ...ly grounded Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages Install...

Page 5: ...ood condition and free from any loose fitting gaskets if applicable in outdoor situations Protected from moisture water steam high humidity as much as reasonably possible RANGETOP Installation Manual...

Page 6: ...Hazard To avoid risk of severe personal injury this appliance requires two or more personnel while handling or moving Possible use of appliance moving devices is recommended WARNING Gas Leak Hazard T...

Page 7: ...l 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 5 DIMENSIONS RANGETOP Step up version of Rangetop Model A In 24 Stand 24 SU 23 875 30 Stand 24 SU 29 8...

Page 8: ...th 24 30 36 Overall Height To top of grate 9 5 16 Step up models to the top of back island 13 1 8 Overall Depth 29 3 4 Gas Requirements 7 W C Natural 11 LP Gas Manifold Pressure 5 W C Natural 10 LP El...

Page 9: ...th 48 60 Overall Height To top of grate 9 5 16 Step up models to the top of back island 13 1 8 Overall Depth 29 3 4 Gas Requirements 7 W C Natural 11 LP Gas Manifold Pressure 5 W C Natural 10 LP Elect...

Page 10: ...he 36 counter height Within 6 side clearance to combustible vertical surfaces above 36 the maximum wall cabinet depth must be 13 and wall cabinets within this 6 side clearance must be 18 above the 36...

Page 11: ...se dimensions provide for safe and efficient operation of the hood This is a vented appliance The appliance should not be installed with a ventilation system that blows air downward towards the ranget...

Page 12: ...pliance should not be installed with a ventilation system that blows air downward towards the rangetop This type of ventilation system may cause ignition and combustion problems with the gas cooking a...

Page 13: ...91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 11 CLEARANCE DIMENSIONS Cook Top Width A Dimension B Dimension 24 24 30 30 30 36 36 36 42 48 48 54 60 60 66 The gas and electrical s...

Page 14: ...818 897 0808 tel 888 753 9898 toll free www americanrange com 12 Electric and Gas supplies should be located inside the cabinet under the countertop 12 by 3 1 2 platform cut out at right far corner s...

Page 15: ...a 16 STP2 Power Cord GAS CONNECTION The gas supply service line must be the same size or greater then the inlet line of the appliance This cook top uses a 1 2 ID NPT inlet Sealant on all pipe joints...

Page 16: ...ed on this cook top since a regulator is built into each unit at the factory Under no condition bypass the built in regulator Flexible Connections If the unit is to be installed with flexible coupling...

Page 17: ...by removing the attachment screw Confirm available access to adequate power and gas See Specifications and Electrical Requirements table Fill out page 1 of this manual with requested data Model numbe...

Page 18: ...13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 16 INSTALLATION STEPS STEP 1 Slide cook top into the cabinet opening Run power cord from the cook top th...

Page 19: ...ual gas shutoff valve E 3 4 or 1 2 gas supply F Use pipe joint compound To avoid risk of personal injury or death leak test of the appliance must be conducted according to the manufacturer s instructi...

Page 20: ...esmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 18 INSTALLATION STEPS STEP 3 Check that unit is level side to side and front to back Side trim of the high corn...

Page 21: ...A 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 19 INSTALLATION STEPS STEP 4 Burner caps are packed in a separate box with the grates Place burner and caps on top of rangetop Pla...

Page 22: ...Check knob rotation function for free and smooth turning FINAL PREPARATION Some Stainless Steel parts may have a plastic protective wrap which must be peeled off All Stainless Steel body parts should...

Page 23: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 24: ...ed licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified installation m...