background image

OWNER’S MANUAL FOR

PROFESSIONAL SERIES FRYERS

MODEL NUMBERS:

AF25,  AF25/25,  AF35/40,  AF35/50,  

AF35/50RM,  AF50/25,  AF75,  AFDS

PROFESSIONAL QUALITY COOKING EQUIPMENT

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

DESIGN

CLASS

FUNCTION

© 2012 American Range

All Rights Reserved

Summary of Contents for AF25

Page 1: ...ERS AF25 AF25 25 AF35 40 AF35 50 AF35 50RM AF50 25 AF75 AFDS PROFESSIONAL QUALITY COOKING EQUIPMENT 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com DESIGN CLASS FUNCTION 2012 American Range All Rights Reserved ...

Page 2: ...___________________________________________ Installed By __________________________ Install Date __________ Gas Type _______________________________________________ Electrical Information ______________________________________ This equipment is design engineered for commercial use only IMPORTANT SERVICE NOTICE Using any part other than genuine American Range factory supplied parts relieves the man...

Page 3: ... you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition Thank you for choosing an American Range product for your kitchen As you can expect this appliance is designed for years of reliable service If you have any questions or comments please contact the de...

Page 4: ... Claim Procedure 3 Rating Plate 3 Clearances 3 INSTALLATION 4 6 Gas Utility Connections Standards Codes 4 Instructions 4 Fryers with Casters 4 Wiring Diagram 5 Models and Parts Identification 6 Installation Checklist 7 OPERATING 8 9 BeforeTurning Burner On 8 Lighting 8 Frying with Shortening 8 Cleaning 9 EXPLODEDVIEW DRAWINGS PARTS LISTS 10 17 AF 25 10 11 AF 35 50 12 13 AF 45 14 15 AF 75 16 17 TRO...

Page 5: ...ctions for local inspectors and for future use WHATTO DO IFYOU SMELL GAS º Do not try to light any appliance º Do not touch any electrical switch do not use any phone in your building º Immediately call your gas company Follow the gas supplier instructions º If you cannot reach your gas supplier call the Fire Department WARRANTY REQUIREMENT For reliable operation and for your own safety this profe...

Page 6: ...nd how to communicate your observations with authorized field service technicians Before using your appliance please read this manual paying special attention to the important safety instructions located in the next several pages ABOUT THIS MANUAL DANGER CAUTION This is the SAFETY ALERT SYMBOL This symbol alerts you to hazards which will result in severe injury or death Hazards or unsafe practices...

Page 7: ...45 999999 CO9999 GAS TYPE NAT TANK ID 2 MAN PRESS IN W C 4 0 INPUT BTU HOUR BURNER CLEARANCES NON COMB COMB 45 000 BACK SIDES 0 0 6 6 SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOORS USING 6 ADJ LEGS OR CASTERS INTENDED FOR OTHER THAN HOUSEHOLD USE ANSI Z83 11a CSA 1 8a 2007 Food Service Equipment RATING PLATE Figure 1 CLEARANCES The appliance must be kept free and clear of all combustible material...

Page 8: ...9 CSA 16 and a quick disconnect device that complies with the standard for quick disconnect devices for use with gas fuel ANSI Z21 41 CSA6 9 Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement The restraining device may be attached to the rear panel of the ...

Page 9: ... 0 0 OFF RED WHITE WHITE BLACK WHITE RED GAS VALVE COMBINATION TH THERMOPILE TP TP TH POWER TO THIS UNIT EXTERNAL ELECTRICAL DO NOT CONNECT ANY WARNING WIRING DIAGRAM Owner s Manual AF Series Fryers 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 5 ...

Page 10: ...l free www americanrange com 6 AF SERIES FRYERS DESCRIPTION AF25 AF25 25 AF35 40 AF35 50 AF35 50RM AF25 50 AF75 AFDS Basket Hanger 1 2 1 1 1 2 1 0 Baskets 1 2 2 2 2 3 2 0 Rack Screen 1 2 1 1 1 2 1 1 Burners 2 4 2 3 3 5 4 Drain Extension Pipe 1 2 1 1 1 2 1 0 Legs 2 4 4 4 4 4 4 4 Regis Card 1 1 1 1 1 1 1 1 U C Manual 1 1 1 1 1 1 1 1 ...

Page 11: ...sent and accessible 0 Gas Supply line properly sized 0 Gas Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been developed to assure proper installation of your oven To validate warranty you must mail e mail or fax this form and a copy of your receipt to American Range Customer Service 13592 Desmond Street Pacoima CA...

Page 12: ...er and the temperature that you cook at will determine how long the fryer oil can be used most can last up to 100 hours Depending on the menu and local eating patterns fryers will usually be operated at full capacity for a few hours a day intermittently for a few hours and be idle the reminder of the time Operating a fryer on an intermittent basis is the primary reason that frying oil must be disc...

Page 13: ...ng device before moving the appliance for cleaning and servicing 3 Drain the fryer into a filtered pan or steel container Flush out sediment at the bottom of fryer with liquid oil 4 Close the drain valve and fill the vessel with a mixture of boil out solution and water 5 Relight the pilot and turn on the burners 6 When the solution starts to boil turn off the thermostat and let the vessel soak to ...

Page 14: ...ies Fryers 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 10 NO OF F 36 23 22 21 29 28 30 27 25 32 33 31 34 35 20 18 16 17 26 24 15 12 8 13 14 19 11 7 10 9 4 5 1 6 3 2 AF 25 ...

Page 15: ...uty 17 A32013 Knob RX Thermostat AF Series 11111 18 A99320 Thermostat Bracket 19 A10007 Switch Hi Limit Millivolt AF 11112 20 A50400 Thermostat RX Millivolt AF 11113 21 A35001 Leg 6 Cone 3 Adjustable Bullet Chrome Plated NSF 22 A35013 Caster 5 Swivel Plate Mount 10423 w Brake NSF 200 lb Load A35012 Caster 5 Swivel Plate Mount 10424 No Brake NSF 200 lb Load A35106 Caster Set of 4 without brakes 23 ...

Page 16: ...Series Fryers 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 12 AF 35 40 26 22 23 21 29 30 28 27 32 33 31 34 8 20 18 16 17 24 25 15 12 14 10 13 9 19 5 4 35 36 1 6 7 3 2 11 ...

Page 17: ...0007 Switch Hi Limit Millivolt AF 11112 20 A50400 Thermostat RX Millivolt AF 11113 21 A35001 Leg 6 Cone 3 Adjustable Bullet Chrome Plated NSF 22 A35013 Caster 5 Swivel Plate Mount 10423 w Brake NSF 200 lb Load A35012 Caster 5 Swivel Plate Mount 10424 No Brake NSF 200 lb Load A35106 Casters Set 4 5 2 w Brake AF ARSP SPSH SWIV Plate Mt 23 A80214 Valve Gas AF 35 40 Nat Gas 7500MVR 1 2 Manifold A80215...

Page 18: ...ries Fryers 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 14 AF 45 2 26 22 23 21 29 30 28 27 32 33 31 34 8 20 18 16 17 24 25 15 12 14 10 13 9 19 5 4 35 36 1 6 7 3 OFF NO 11 ...

Page 19: ...rmostat RX Millivolt AF 11113 21 A35001 Leg 6 Cone 3 Adjustable Bullet Chrome Plated NSF 22 A35013 Caster 5 Swivel Plate Mount 10423 w Brake NSF 200 lb Load A35012 Caster 5 Swivel Plate Mount 10424 No Brake NSF 200 lb Load A35106 Caster Set 4 5 2 w Brake AF ARSP SPSH Swiv Plate Mt 23 A80102 Valve Gas AF Series Nat Gas 11114 3 4 Manifold A80103 Valve Gas AF Series LP Gas 11114 3 4 Manifold 24 A9927...

Page 20: ...ries Fryers 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 16 AF 75 26 27 25 33 34 32 OFF NO 31 1 35 36 2 18 24 23 22 21 28 30 29 19 20 9 17 13 14 16 12 11 7 8 5 3 4 10 6 15 ...

Page 21: ...2 Door Assembly AF 75 Heavy Duty 5243 Stainless 18 A10007 Switch Hi Limit Millivolt AF 11112 19 A44003 Nut Speed 6 Push Black 10601 20 A99219 Hinge Top Door AF Series 5036 Heavy Duty 21 A99220 Hinge Bottom Door AF Series 5035 Heavy Duty 22 A32013 Knob RX Thermostat AF Series 11111 24 A50400 Thermostat RX Millivolt AF 11113 25 A35001 Leg 6 Cone 3 Adjustable Bullet Chrome Plated NSF 26 A35012 Caster...

Page 22: ...ough Unit preheats to 350ºF in about ten minutes Thermostat may be defective Unit will require service Too little gas pressure dirty gas line Call for authorized service SYMPTOM General frying problems Temperature too low or too high Set unit to recommended temperature for foods being fried Thermostat out of calibration Unit will require service Always disconnect the gas service before cleaning or...

Page 23: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com ...

Page 24: ...a certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified installation must be made available to American Range for verification If installation was not performed by a certified licensed contractor be prepared to submit a major credit card for payment for proper ...

Reviews: