background image

 

 

 

ONE-TOUCH WIRELESS HEALTH TRACKER 

 

BODY LIFE TRACKER 

User Manual 

Model: VA06 

 

 

 

 

 

 

 

Document No  : AMI-PRD-UM-B-VA06 

Version  

:  1.0 

Date 

 

:  25.09.2015 

Summary of Contents for B.O.L.T VA06

Page 1: ...ONE TOUCH WIRELESS HEALTH TRACKER BODY LIFE TRACKER User Manual Model VA06 Document No AMI PRD UM B VA06 Version 1 0 Date 25 09 2015 ...

Page 2: ...ends India Private Ltd be held liable for any loss expenses or damage of any kind whatsoever whether direct indirect incidental or consequential arising from the design or use of this product or the support materials provided with the product Limited Warranty No warranties are made either expressed or implied with regard to the contents of this work its merchantability or fitness for a particular ...

Page 3: ...acker Please read this User Manual thoroughly to ensure safe and correct use of the product Please keep this User Manual for future reference B O L T is a medical gadget with NiBP Non invasive Blood Pressure SpO2 Pulse Oximeter Infrared Thermometer IRT and Gluchobin Invasive combined into a small form factor device which gets controlled from a mobile device B O L T is a cloud enabled solution With...

Page 4: ...Oxygen Level Measurement Procedures 10 Blood Oxygen Level Classification 11 Temperature Measurement Procedures 11 Temperature Classification 12 Blood Glucose Level Measurement Procedures 13 Blood Glucose Level Classification 15 Blood Hemoglobin Level Measurement Procedures 16 Blood Hemoglobin Level Classification 18 Blood Cholesterol Level Measurement Procedures 19 Blood Cholesterol Level Classifi...

Page 5: ...ature measurement Use dust cover for Ear Thermometer during the temperature measurement Place the finger inside the SpO2 probe properly during the Blood oxygen level measurement Lancet needle Glucose strips Hemoglobin strips and Cholesterol strips are meant for single user Single use only Lancet is to be used only on the tip of finger and not anywhere else Do not set the pricking lancet at a highe...

Page 6: ...e between 2 C to 32 C 36 F to 90 F Do not refrigerate or freeze the test strips Keep the test strips slot of the Gluchobin device free from dust After pulling out the test strip from its container seal the cap of the container tightly to protect test strips Know Your Unit The base unit has an elegant look and feel with two LED indicators an accessory connector and a power ON OFF sliding switch as ...

Page 7: ...evice 1 Download and Install B O L T application from the Play store Application store Windows application market 2 On successful installation launch the B O L T application in the mobile device 3 Create a User Name with your Email ID or use Facebook Google Credentials for login 4 On successful Login provide permission for cloud service by enabling the Save in cloud option and enter near and dear ...

Page 8: ...e hand during the measurement Blood Pressure measurement with B O L T B O L T enables connecting an air hose through which the blood pressure is monitored Connecting air hose with the gadget and launching B O L T application 1 Insert the BP connector plug into the BP socket firmly as shown above 2 Switch ON the gadget using the ON OFF sliding switch 3 Enable Bluetooth and Internet Connectivity in ...

Page 9: ...re that the person remains stable until the application displays the results 9 On successful measurement the Blood Pressure and Pulse rate are displayed and a copy of reading will be mailed to your Near Dear mail IDs on saving the data 10 Multiple readings can be taken with atleast 1 minute interval by selecting the auto reading option Note On Successful pairing of the mobile device Bluetooth ligh...

Page 10: ...s connecting a SpO2 probe through which the blood oxygen level is measured Connecting SpO2 probe with the gadget Insert the SpO2 connector into the socket firmly as shown below Note Ensure to clean your hands before taking SpO2 measurement Some SpO2 reading fluctuation may be occurred of below 85 for certain ethnicity group If the SpO2 values are deviated below 70 or above 100 ensure that the user...

Page 11: ... Please note that this table can give only a generic view Consult with your physician for accurate assessment SpO2 Classification Range Hypoxemia low 95 Normal 95 100 Temperature Measurement Procedures Mandatory instructions to be followed during temperature measurement Relax yourself in a comfortable position Use new dust cover for each measurement Place the Ear Thermometer firmly into the ear ca...

Page 12: ...e pointer maintains horizontal position as displayed above 4 Select the Body temperature option from the application screen 5 On successful measurement the temperature value is displayed and a copy of the reading will be mailed to your Near Dear mail IDs on saving the data Temperature Classification Please note that this table can give only a generic view Consult with your physician for accurate a...

Page 13: ...during the measurement Relax yourself in a comfortable position Blood Glucose level measurement with B O L T B O L T enables connecting a Gluchobin through which the glucose test strip are inserted for measurement Using Lancet pen and Lancet 1 Unscrew and remove the lancet pen s adjustable tip as shown below 2 Insert a lancet into the carrier as shown below 3 Twist off the protective cover ...

Page 14: ...trigger rises up Release the sliding barrel it will move back to its original position Connecting Gluchobin with the gadget 7 Insert the Gluchobin connector into the socket firmly as shown below Gluchobin connected to B O L T Device 8 Select Gluchobin and choose the Glucose option from the application screen of the mobile device 9 Insert the blood glucose test strip into the test strip slot of the...

Page 15: ...Pull the test strip out of the Gluchobin 19 Unscrew the adjustable tip of the lancet pen 20 Place the protective cover of the lancet back on the lancet as shown below 21 Discard the used lancet in an appropriate container 22 Screw the adjustable tip back on the lancet pen Note Ensure that the test strip gets enough blood Else try to use a new test strip to do the test again To avoid accidental inj...

Page 16: ...nables connecting a Gluchobin through which the hemoglobin test strip are inserted for measurement Using Lancet pen and Lancet 1 Unscrew and remove the lancet pen s adjustable tip as shown below 2 Insert a lancet into the carrier as shown below 3 Twist off the protective cover 4 Replace the adjustable tip tightly Choose a desired skin penetration depth by rotating the top portion of the adjustable...

Page 17: ...get 7 Insert the Gluchobin connector into the socket firmly as shown below Gluchobin connected to B O L T Device 8 Select Gluchobin and choose the Hemoglobin option from the application screen of the mobile device 9 Insert the hemoglobin test strip into the test strip slot of the Gluchobin as shown below 10 Click Start in the application screen of the mobile device 11 Clean your finger with alcoho...

Page 18: ...lancet in an appropriate container 21 Screw the adjustable tip back on the lancet pen Note Ensure that the test strip gets enough blood Else try to use a new test strip to do the test again To avoid accidental injury always remove the used lancet immediately after each test Blood Hemoglobin Level Classification Population Non Anemic g dl Mild g dl Moderate g dl Severe g dl Children 6 59 months of ...

Page 19: ...ring the measurement Relax yourself in a comfortable position Blood Cholesterol level measurement with B O L T B O L T enables connecting a Gluchobin through which the cholesterol test strip are inserted for measurement Using Lancet pen and Lancet 1 Unscrew and remove the lancet pen s adjustable tip as shown below 2 Insert a lancet into the carrier as shown below 3 Twist off the protective cover ...

Page 20: ...rigger rises up Release the sliding barrel it will move back to its original position Connecting Gluchobin with the gadget 7 Insert the Gluchobin connector into the socket firmly as shown below Gluchobin connected to B O L T Device 8 Select Gluchobin and choose the Cholesterol option from the application screen of the mobile device 9 Insert the cholesterol test strip into the test strip slot of th...

Page 21: ...ew the adjustable tip of the lancet pen 19 Place the protective cover of the lancet back on the lancet as shown below 20 Discard the used lancet in an appropriate container 21 Screw the adjustable tip back on the lancet pen Note Ensure that the test strip gets enough blood Else try to use a new test strip to do the test again To avoid accidental injury always remove the used lancet immediately aft...

Page 22: ...easurement the BMI value is displayed which can be compared with the above BMI range classification table Battery Care Power adapter is included in the pack and the specifications are mentioned below AC input 100 240V Frequency 50Hz to 60Hz 0 35A Max DC output 5V 2A Connect the AC power adapter to the power source and micro USB port to the base unit s USB Power socket Charge the base unit for mini...

Page 23: ...can work normally while charging Replacement of Battery Pack Manufacturer highly recommended to change the battery of the base unit for every 1 year at the AMI authorized service center Use AMI recommended battery for replacement Replacement procedure 1 Switch off the base unit before removing the back cover for the battery replacement 2 Remove the single screw on the upper portion of the battery ...

Page 24: ...ery power of the gadget in the computer mobile device The indicator displays low battery power of the gadget in the computer mobile device SYS Systolic blood pressure in mmHg DIA Diastolic blood pressure in mmHg PUL min Pulse per minute Flashing of the Bluetooth light indicates that the gadget is waiting for pairing with the mobile tab Steady Bluetooth light indicates that the gadget is paired and...

Page 25: ...ode Symbol for ENVIRONMENT PROTECTION Symbol for KEEP DRY Symbol for MANUFACTURER Symbol for MANUFACTURED DATE Symbol for SERIAL NUMBER Symbol for EUROPEAN REPRESENTATIVE Symbol for COMPILES WITH MDD93 42 EEC REQUIREMENTS Symbol for Federal Communication Commission Symbol for Read the documentation Symbol for Warning Symbol for Temperature limitation Symbol for Shock Protection ...

Page 26: ...meter Body Temperature measurement method Tympanic Infrared based Body temperature range 34 C to 42 C 93 2 F to 107 6 F Body temperature Accuracy 0 2 C from 36 C to 39 0 C 0 4 F from 95 0 F to 102 6 F 0 3 C from 39 1 C to 44 0 C 0 5 F from 102 38 F to 111 2 F IRT Display resolution temperature range 0 1 F IRT Unit Dimensions 84 8 L X 18 H X 26 6 D mm Highest width along the profile IRT Unit Weight...

Page 27: ...ustomer care support by calling 1800 419 9868 Enclose the warranty card Proof of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Customer Care Support AMI s flexible approach allows the customers to get Technical Support and Warranty services for B O L T through our customer care support T...

Page 28: ...ts Reserved American Megatrends India Private Ltd American Megatrends International GmbH Truderingerstraße Truderinger Strasse 283 81825 München Munich Deutschland Germany Tel 49 89 969995 10 Support 49 89 969995 11 Fax 49 89 969995 19 Email europesales ami com ...

Reviews: