Specifications-Indoor Dome 

Operational 

Pan/Tilt: 

Manual Pan Speed .........................0.2°-100° per second 
 

(scaled to zoom position) 

Manual Tilt Speed......................... 0.25°-100° per second 
 

(scaled to zoom position) 

Preset Pan/Tilt Speed............ 220° per second maximum 
Pan Travel ................................. 360° continuous rotation 
Tilt Travel................................................................ >100° 
Pan/Tilt Accuracy..................................................... ±0.5° 

23x Day/Night

 Camera Zoom Functions: 

Optical Zoom ............................................................. 23X 
Digital Zoom .............................................................. 10X 
Zoom Pause ......................................... 23X selectable or 
 35X 

default 

Total Zoom .............................................................. 230X 
Maximum Zoom Stop....... 46X, 69X, 92X (default), 115X, 
 

138X, 161X, 184X, 207X, 230X 

Zoom/Focus Accuracy ........................................... ±0.5% 

Auto Synchronization: 

Line Locked ........................ Remote V-phase adjustment 
Internal.......................................... Built-in sync generator 
Address Range....................................................... 1-255 

Number of Presets: 

VM16 / ADTT16........................... 96 with SensorNet 485 
VM32 / AD32 ............................... 96 with SensorNet 485 
AD2150..............................................64 with Manchester 
 

16 with RS-422 (using AD2083-02A) 

VM96 .................... Virtual with RS-422 or SensorNet 485 
VM168 / AD168 ................................64 with Manchester, 
 

RS-422 or SensorNet 

 

16 with RS-422 (using AD2083-02A) 

AD2050..............................................64 with Manchester 
 

16 with RS-422 (using AD2083-02A) 

Direct View™ Access Time ...........<1 second to position. 
 

Full zoom in <4 seconds. 

 

Focus on VM16, VM32 and 

 

VideoManager systems is <1 second. 

 

Focus on VM96 and RV2715 systems 

 

is <7 seconds 

Programmable Patterns 

Number Patterns...........................................................16 

Storage 

Program Storage ................ 256 Kbytes of Flash memory 
Data Storage .................................. 128 Kbytes of SRAM 

Configuration Menu 

Languages ................English, French, German, Spanish, 
 

Italian, and Portuguese 

Electrical 

Input Voltage.....................................18-30Vac, 50/60 Hz 
 

UL Class 2 LPS 

Design Tolerance ..............................16-36Vac, 50/60 Hz 
Power Consumption......................................... 16W max. 
Current ........................................................... 0.85A max. 
Allowable Drop Out ............................................... 100ms 
Power On In-Rush Current........................................1.5A 

Surge Protection: 

Video Output ............................... Low capacitance Zener 
 

suppressor 6.5V, 1500W 

Power Line ......................... TVS rated at 60V, 1.5 joules, 
 

250A 8/20µs impulse 

RS-422.......................................... TVS rated at 9.8V/1A, 
 20V/25A, 

500W, 

 8/20µs 

impulse 

Manchester/ 
SensorNet 485 .................... Gas discharge tube rated at: 
 

8/20µs impulse discharge current 

 

of 10kA, ten 8/20µs impulse 

 

discharge current of 5kA 

 

Isolation transformer coupled 2000Vrms 

 

PTC fuse protects transformer. 

 

TVS rated at 9.8V/1A, 20V/25A, 

 

500W, 8/20µs impulse 

Alarm Input.................................... TVS rated at 9.8V/1A, 
 

20V/25A, 500W, 8/20µs impulse 

Alarms Inputs/Control Outputs: 

When no I/O board is used: 

Inputs ........................................ 1 dry contact/3.5mA sink 
Outputs ......................................... 1 open collector driver 
 

@ 12Vdc, 40mA 

When I/O board is used: 

Inputs ...................................... 4 dry contacts/3.5mA sink 
Outputs ....................................... 4 open collector drivers 
 

@ 12Vdc, 40mA 

Environmental 

Operating Temperature........ –10° to 50°C (14° to 122°F) 
Relative Humidity .....................0 to 95% non-condensing 
Storage Temperature ................................ –20°C to 65°C 
 

(–4°F to 149°F) 

Summary of Contents for SpeedDome Ultra VIIE

Page 1: ...Ultra VIIE camera dome features that are not currently covered in your operator s manual This supplement supports information found in the following manuals Day Night Camera Dome Configuration Utility Operator s Manual 8200 0184 04 NOTE Keep this supplement with your operator s manual for reference purposes If you need assistance Contact your Sales Representative New SpeedDome Ultra VIIE Features ...

Page 2: ...ible controllers 10 DirectSet Night Mode Sets the dome IR mode setting to ON The dome switches to full time black and white B W mode 11 DirectSet Day Mode Sets the dome IR mode setting to OFF The dome switches to full time color mode 12 DirectSet Auto Day Night Mode Resumes the most recently selected automatic IR mode setting Auto High B W mode activates 30 lux Auto Mid B W mode activates 3 lux Au...

Page 3: ...E is programmed from on screen menus that are accessible through your controller keyboard virtual keyboard or Touch Tracker The starting point for programming is the Configuration Menu To access the menu on most controllers press and hold the following buttons in sequence Iris Open Focus Far Zoom Out Consult your keyboard manual for instructions if unable to access menu programming When programmin...

Page 4: ...oviding motion detection based on Preset camera views Motion detection can be programmed for any of the 96 Presets defined in the dome The motion detection feature is programmed from the Select Preset to Program screen Understanding Motion Zones Motion Detection is programmed by positioning motion zones represented by rectangular blocks within a Preset scene When motion occurs within any of the mo...

Page 5: ...ngs Options are On OFF 5 Use the joystick to highlight EXIT and press Focus Far to select 6 When the Dome Configuration Menu appears use the joystick to highlight EXIT AND SAVE CHANGES and press Focus Far Steps to Programming Motion Detection Follow the steps below to program motion detection 1 Access the Dome Configuration Menu Figure 9 by pressing Iris Open Focus Far and Zoom Out on your control...

Page 6: ...espond when motion is detected Choices are No Action no action occurs Preset 1 96 calls a Preset Pattern 1 16 runs a Pattern Output 1 4 activates an output When No Action is programmed on the motion detection screen the dome s return to a Home position is delayed as long as motion occurs within the time specified on the return to home screen 9 Press the Focus Far button The Motion Detection Setup ...

Page 7: ...ls how long each Preset remains on screen before switching to another Preset Up to 16 Sequences can be created each with 16 steps Presets Steps to Programming Sequences Follow the steps below to program Sequences 1 Access the Dome Configuration Menu Figure 14 by pressing Iris Open Focus Far and Zoom Out on your controller Figure 14 2 Use the joystick to highlight Alarms Areas Home Presets PZ and P...

Page 8: ...Focus Far to save Running Sequences 1 16 Two options are available for running Sequences Option 1 If your keyboard supports the DirectSet command you can use it to run a Sequence immediately see DirectSet Menu page 2 Consult your keyboard manual for information on DirectSet functions Option 2 Use the Set Home Position method to schedule one Sequence to run when the dome returns to its home positio...

Page 9: ...when configuring the system for Patterns Setting Description Off Allows programming of three fixed speed Patterns The three Patterns are limited to a total of 99 pan tilt zoom movements e g if one Pattern uses 50 movements the remaining two Patterns are limited to a total of 49 movements Note The VM1 and VM96 systems only support the OFF setting 3 Allows programming of three variable speed Pattern...

Page 10: ...dome as desired for the Pattern 4 Execute the keyboard s Pattern save command to save the Pattern Running 16 Patterns When a dome is configured for 16 Patterns running a Pattern requires displaying the Pattern Select screen Figure 23 Follow the steps below to run a Pattern 1 Enter the appropriate keyboard command to run Patterns 1 2 or 3 The Pattern Select screen appears 2 Move the joystick to hig...

Page 11: ...s AD2150 AD2350 Supported Protocol RS 4221 Maximum Presets 162 Maximum Patterns3 16 DirectSet Menu Not supported Address Range 1 32 Notes 1 Requires the AD2083 02 series code converter 2 Preset information is stored at the converter not the dome 3 Patterns are limited by time and the number of available dome commands AD1650 Supported Protocol RS 4221 Maximum Presets 162 Maximum Patterns3 16 Direct...

Page 12: ...s3 Address Range 1 48 1 48 Notes 1 Preset information is stored at the host not the dome 2 Patterns are limited by time and the number of available dome commands 3 Requires firmware 1 07 or newer and a compatible keyboard MegaPower 1024 Supported Protocol RS 4221 Manchester Maximum Presets 162 or 603 64 Maximum Patterns4 16 16 DirectSet Menu Not supported Not supported Address Range 1 10245 1 1024...

Page 13: ...VideoManager systems is 1 second Focus on VM96 and RV2715 systems is 7 seconds Programmable Patterns Number Patterns 16 Storage Program Storage 256 Kbytes of Flash memory Data Storage 128 Kbytes of SRAM Configuration Menu Languages English French German Spanish Italian and Portuguese Electrical Input Voltage 18 30Vac 50 60 Hz UL Class 2 LPS Design Tolerance 16 36Vac 50 60 Hz Power Consumption 16W ...

Page 14: ...R mode with 1 4 s open shutter White Balance Through the Lens TTL Automatic Tracing White balance ATW NTSC Effective Pixels 724 H x 494 V pixels Scanning 525 lines 60 fields 30 frames Horizontal 15 734kHz Vertical 59 9Hz PAL Effective Pixels 724 H x 582 V pixels Scanning 625 lines 50 fields 25 frames Horizontal 15 625kHz Vertical 50Hz Lens Design Type Aspherical Focal Length 3 6 to 82 8mm Aperture...

Page 15: ... empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any p...

Reviews: