Warnings 

Please review the following warnings before you 
install or service the camera dome.  

ALWAYS USE: 

  Proper safety equipment for the location and 

type of installation.  

  Proper lift equipment to reach the installation.  

  Safety features of the lift equipment.  

BE SURE: 

  Electrical power is not connected to the dome 

when connecting wires. Camera will move when 
power is applied.  

  Electrical power is not connected to nearby 

fixtures that you might touch during installation. 

DO NOT install this dome in hazardous areas 
where highly combustible or explosive products are 
stored or used. 

This dome runs on 24Vac.

 DO NOT connect line 

voltage to this dome. 

North America power requirements:

 In North 

America, this device is intended to be supplied 
from a Class 2 power supply. 

This installation should be made by a qualified 
service person and should conform to all local 
codes. 

EU power requirements:

 This product runs on 

24Vac. In the EU, it is intended to be powered from 
a Limited Power Source. A limited power source is 
a certified source of SELV, and if inherently limited, 
with 8 amps maximum output current, and a 
maximum of 100VA available; or if not inherently 
limited, fused with a maximum value of 3.3 Amps, 
meeting section 2.11 of IEC950, and a maximum of 
250VA available. The power supply can be 
obtained through Sensormatic or through another 
source where the provider can furnish the 
verification. This is required to assure electrical 
safety in the product. 

Stromanforderungen in der EU:

 Dieses Produkt 

wird mit 24 V Wechselstrom betrieben. In der EU 
ist es für den Betrieb durch eine begrenzte 
Stromquelle vorgesehen. Eine begrenzte 
Stromquelle ist eine zertifizierte SELV-Quelle 
(Schutzkleinspannung), bei inhärenter Begrenzung 
mit einem maximalen Ausgangsstrom von 8 A und 
100 VA maximaler Verfügbarkeit, bei nicht 
inhärenter Begrenzung mit einer maximalen 
Sicherung von 3,3 A gemäß Abschnitt 2.11 der 
IEC950 und 250 VA maximaler Verfügbarkeit. Das 
Netzteil kann über Sensormatic oder eine andere 
Quelle bezogen werden, wobei der Anbieter den 
Nachweis der Konformität bereitstellen sollte. Dies 
ist zur Gewährleistung der elektrischen Sicherheit 
des Produktes erforderlich. 

Summary of Contents for RASEL Series

Page 1: ...late instructions for the plate are supplied separately CAUTION Save the box and packing materials These materials are required should you need to ship the dome to a repair center Note The dome accepts either cable or conduit If running cable through a plenum ceiling either plenum rated cable or flexible conduit is required 2006 Sensormatic Electronics Corp Contents Warnings 2 Before You Begin 3 I...

Page 2: ...tended to be powered from a Limited Power Source A limited power source is a certified source of SELV and if inherently limited with 8 amps maximum output current and a maximum of 100VA available or if not inherently limited fused with a maximum value of 3 3 Amps meeting section 2 11 of IEC950 and a maximum of 250VA available The power supply can be obtained through Sensormatic or through another ...

Page 3: ... Max devices per cable run 32 10 3 Power data and video cables can be ordered separately or within a composite cable that can be ordered in various lengths Plenum rated cables must be used in indoor ceilings used for environmental air return called other air space in the National Electrical Code Order parts through your distribution network Note If you order cable from an outside source wire color...

Page 4: ...tion at the other end of the cable The figure below shows twisted pair cable connections See installation guide 8200 0298 01 for details Table 1 Maximum cable length and worst case low line voltages Indoor Dome Worst Case Meters AC Power Source Low Line V Feet 28 VA 117 130 425 Transformer 100 80 250 5604 0006 01 90 60 200 50 VA 117 160 525 Transformer 100 100 325 5604 0044 01 90 60 200 1 position...

Page 5: ...RS 422 1 99 For example for address 107 set SW3 to 1 SW2 to 0 black dot and SW1 to 7 Compatibility with the VM96 Controller If using a VM96 controller the controller must be Version 5 2 or higher Power Up Routine After power is connected to the dome the dome performs a homing routine During the homing process the camera will pan and then either Go to the start point of the apple peel pattern or If...

Page 6: ... Polarity 2 No Polarity Manch 1 WHT 2 BLK Comm P9 Video 24Vac P10 RS422 Switch 6 7 Off all others On 8 On Off 7 6 5 4 3 2 1 RS422 1 Rx 2 Rx 4 Set address switches SW1 SW2 and SW3 for the address for example 001 016 for VM16 001 096 for VM96 5 If daisy chaining domes the dome furthest from the video controller requires that termination switch S1 remain in the terminated position resistor symbol All...

Page 7: ...ighten the connector screws DO NOT over tighten the connectors 13 Plug video or Twisted Pair Adapter power and data communications cables into their mating connectors in the top of the dome housing WARNING Ensure power is off at the source when connecting cables Otherwise the dome will operate during installation 14 Reattach the cover plate to the dome housing 15 Using safety wire attach the dome ...

Page 8: ...the last position in memory Once the camera stops the camera is online and is ready to be controlled Also green red and yellow LEDs will light in various patterns to indicate status Typically you do not need to view these LEDs unless a failure occurs during or after the routine See Troubleshooting for an explanation of the LED patterns 19 Once the homing routine completes affix the bubble to the d...

Page 9: ...d and yellow LEDs through the housing LED Indication Cause Yellow blinks Wiring OK Red flickers Green blinks RS 422 wired backwards Red blinks Green flickers A wire is not connected Fix wiring 2 Reset the dome to the desired address No video 1 Check the video cable and its connection to the dome If not OK fix or replace the cable 2 Check the iris setting Open iris or set to auto iris 3 If the prob...

Page 10: ...ble Assembly Clear 0100 2458 01 6 Bubble Assembly Smoked 0100 2458 02 Tilt Assy 0400 1207 01 NTSC 02 PAL 7 Base Tilt 0500 9110 01 8 Gear Camera Base 0500 9112 01 9 Tilt Upright 2 0500 9168 01 10 Camera 1 4 CCD NTSC STD 22XM 2003 0049 01 11 Camera 1 4 CCD PAL STD 22XM 2003 0049 02 12 Timing Belt 2500 0041 01 13 Tilt Motor with Pully 3501 0028 01 14 PCB Tilt Sensor 0312 1524 01 15 Ribbon Cable 20mm ...

Page 11: ...SPEEDDOME OPTIMA LT INDOOR CAMERA DOME 8200 0181 01 REV E INSTALLATION AND SERVICE GUIDE 11 of 14 8 12 9 17 16 19 20 Tilt Assy 0400 1207 01 02 Base Assy 0404 0008 01 18 7 13 14 15 10 11 ...

Page 12: ...l Noise 50dB typical Minimum illumination 1 0 lux 20 IRE Gain control Automatic AGC White balance Through the Lens TTL Automatic Tracing White Balance ATW NTSC version Pickup device 768 H x 494 V pixels Scanning 525 lines 60 fields 30 frames Horizontal 15 734kHz Vertical 59 9Hz PAL version Pickup device 752 H x 582 V pixels Scanning 625 lines 50 fields 25 frames Horizontal 15 625kHz Vertical 50Hz ...

Page 13: ...r node Node repeaters SensorNet junction boxes Cable topologies Daisy chain Backbone Star Transmission medium Single non polarized unshielded twisted pair UTP 22AWG Wire configuration Single unshielded twisted pair UTP 22AWG non polarized Connector Plug in Euro style terminal block 5 08mm Terminating resistor 120 ohms switch selectable EIA 422 Communications Network Distance 1km Maximum Loads 10 n...

Page 14: ... very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose NOTICE ...

Reviews: