American Dynamics ADTT16E Touch Tracker Installation Instructions Manual Download Page 5

ADTT16E TOUCH TRACKER CONTROLLER WITH INTELLEX 

8000-2637-02, REV. C 

INSTALLATION INSTRUCTIONS 

5 of 6 

 

 

Calibrating the Tracker Ball 

1. Press 

Menu

. The 

Calibration

 menu option 

appears on the first line. 

2.  Press the left zoom/focus button (line 1) to 

select the 

Calibration

 menu option. 

3.  Follow the instructions on the LCD screen. 
4. Press 

Menu

 to exit. 

 

If you do not follow each instruction on the 
screen, the dome may not function properly. 
Re-calibrate the Tracker Ball if the dome does 
not pan or tilt properly. 

Calibration is only for 

the ADTT16E Touch Tracker.

 

Configuring Devices 

1. Press 

Menu

2.  Using the Tracker Ball, scroll down to 

Config 

Devices

3.  Press the left zoom/focus button (line 1) or right 

zoom/focus button (line 2) to select the 

Config 

Devices

 menu option. 

4. Press 

Next

 to step to the device configuration 

for this installation. 

5. Press 

Menu

 to select the device configuration 

and exit. 

Resetting a Dome 

1.  Use the number buttons to select the dome to 

reset, then press 

Cam

2. Press 

Menu

3.  Using the Tracker Ball, scroll down to 

Reset 

Dome

4.  Press the left zoom/focus button (line 1) or right 

zoom/focus button (line 2) to select the 

Reset 

Dome

 menu option. 

 

The ADTT16E Touch Tracker sends a request 
to the selected dome to reboot. After a brief 
delay, the controller returns to Camera Control 
Mode. 

 

 

Toggling between Zoom 
and Focus 

1. Press 

Menu

2.  Using the Tracker Ball, scroll down to 

Tog Zoom/Focus

3.  Press the left zoom/focus button (line 1) or right 

zoom/focus button (line 2) to select the 

Tog Zoom/Focus

 menu option. 

4. Press 

Next

 to switch the zoom and focus 

functions between the right and left buttons. 

5. Press 

Menu

 to exit. 

Adjusting V-Phase 

1. Press 

Menu

2.  Using the Tracker Ball, scroll down to 

Adjust 

V-Phase

3.  Press the left zoom/focus button (line 1) or right 

zoom/focus button (line 2) to select the 

Adjust 

V-Phase

 menu option. 

4. Press 

Next

 or 

Previous

 to observe V-Phase 

through the oscilloscope or Fluke scope. 

5. Press 

Menu

 to exit. 

 

 

 

Off-line domes or fixed cameras will generate a 
warning beep and disallow use of the V-Phase 
utility.  

Summary of Contents for ADTT16E Touch Tracker

Page 1: ...ion 3 Intellex 2 0 Connection 4 Calibrating the Tracker Ball 5 Configuring Devices 5 Resetting a Dome 5 Toggling between Zoom and Focus 5 Adjusting V Phase 5 Providing System Information 6 Performing SensorNet Ping Test 6 2005 Sensormatic Electronics Corp About this Guide This installation guide explains the wiring of the ADTT16E Touch Tracker Controller with the Intellex Digital Video Management ...

Page 2: ...all or other surface within 3m 10 of the ADTT16E Touch Tracker 3 Connect the power transformer and SensorNet cable to J3 on the EIM 4 Connect the DB9M DB9F Serial Cable PN 6003 0017 05 to the DB9 connectors on the EIM and Intellex back panel Refer to the illustrations on pages 3 or 4 for additional information 5 Connect the data cable from J1 on the main ADTT16E Touch Tracker EIM to the Remote por...

Page 3: ...und White 5 24 Vac B PIN FUNCTION 5 4 3 2 1 J Box 1 EIM 1 DB9 M RJ45 RJ45 P1 P2 P3 P4 P5 P6 P8 UniCard P3 UniCard P3 ASSY 0301 0340 01 REV 3 2 1 TERMINATED DB9 F P1 P2 P3 P4 P5 P6 P8 3 5 4 J Box 2 Main Touch Tracker Intellex 1 x with DB9 Connector 24 Vac A 24 Vac B Ground Serial Cable PN 6003 0017 05 RPNR00 Terminate E1 on EIM 1 E1 The ma ximum combined SensorNet cable length is 1000 m 3000 5 4 3 ...

Page 4: ...PNR00 Terminate E1 on EIM 1 E1 The maximum combined SensorNet cable length is 1000 m 3000 5 4 3 2 1 COLOR Orange 1 Host A Yellow 2 Host B Orange Auxiliary A Yellow 4 Auxiliary B PIN FUNCTION COLOR Orange 1 SensorNet A White 2 28 Vac Red 3 Ground Black 4 28 Vac Yellow 5 SensorNet B PIN FUNCTION COLOR Orange 1 SensorNet A Yellow 2 SensorNet B Black 3 24 Vac A Red 4 Ground White 5 24 Vac B PIN FUNCTI...

Page 5: ...e number buttons to select the dome to reset then press Cam 2 Press Menu 3 Using the Tracker Ball scroll down to Reset Dome 4 Press the left zoom focus button line 1 or right zoom focus button line 2 to select the Reset Dome menu option The ADTT16E Touch Tracker sends a request to the selected dome to reboot After a brief delay the controller returns to Camera Control Mode Toggling between Zoom an...

Page 6: ...Max 55 66 77 88 Pan FSR Calibration Values Left Right Up Down Product Code F 7000 0020 0102 Indicates Flash PROM Product Code E 0701 0010 0105 Indicates EEPROM 5 Press Menu to exit Performing SensorNet Ping Test 1 Use the number buttons to select a dome to reset then press Cam 2 Press Menu 3 Using the Tracker Ball scroll down to Ping Dome TTR 4 Press the left zoom focus button line 1 or right zoom...