35
2. Electrical Service Specifications
IMPORTANT: THE DRYER
MUST BE
CONNECTED TO THE ELECTRIC SUPPLY
SHOWN ON THE DATA LABEL THAT IS AFFIXED TO THE REAR OF
THE RIGHT HAND ELECTRICAL ENCLOSURE.
WARNING: 208 VAC and 230 VAC
ARE NOT THE SAME
. Any damage done to the dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC
reserves the right to make changes in specifications at any time, without notice or
obligation.
M LG-410 (Gas)
M LS-410 (Steam)
25 HP (ADC Part No. 181006) Blower Motor
7-1/2 HP (ADC Part No. 181017) Drive
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC
AND
230 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3Ø dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
Dual Element
Time Delay
CIRCUIT
BREAKER
208
3ø
3/4
81
#3
100
110
230
3ø
3
78
#3
100
110
380
3ø
3/4
49
#6
60
90
416
3ø
3/4
44
#6
60
90
460/480
3ø
3/4
40
#8
60
80
Summary of Contents for ML-410
Page 7: ...3 ML 410 Reference Guide ...
Page 8: ...4 ...
Page 28: ...24 MLG 410 1 Door Forward Tilt with Sprinkler ...
Page 31: ...27 MLS 410 2 Door 2 Way Tilt ...
Page 67: ...ADC 113128 1 03 13 00 25 ...