2. Electrical Service Specifications
IMPORTANT
: The dryer
must be
connected to the electric supply shown on the data label that is
affixed to the back of the dryer, at the upper right hand corner. In the case of
208 VAC or 240 VAC, the supply voltage
must match
the electric service
specifications of the data label
exactly
.
IMPORTANT
: The wire size
must be
properly sized to handle the related current.
WARNING
:
208 VAC and 240 VAC ARE
NOT
THE
SAME.
Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE
:
ADC
reserves the right to make changes in specifications at any time, without notice or
obligation.
ADG-78 II (Gas)
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT
: 208 VAC
AND
230/240 VAC
ARE NOT THE SAME
.
W
HEN
ORDER ING
,
SPEC IF Y
E XAC T
V OLTAGE
.
NOTE
:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5
ONLY
.
B. Circuit breakers are thermal magnetic (industrial) type
ONLY
. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers
must be
3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MIMIMUM
WIRE SIZE*
FUSING
CIRCUIT
BREAKER
D
UAL
E
LEMENT
T
IME
D
ELAY
120
1ø
2
13
#10
20
25
208
1ø
2
8
#14
12
15
208
3ø
3
5
#14
8
15
230
1ø
2
7
#14
10
15
230
3ø
3
5
#14
8
15
240
1ø
2
7
#14
10
15
380-400
3ø
3
3
#14
5
15
416
3ø
3
3
#14
5
15
460
3ø
3
3
#14
5
15
* AWG Stranded Wire ... for individual lenghts less than 100 feet.